Graco 308791E Operation, Setting the Cup Air Pressure, Setting the Gun Air Pressure

Page 4
Operation

Operation

Pressure Relief Procedure WARNING

Never exceed 20 psi (1.4 bar) static air pressure to the cup. Exceeding the maximum working pressure of the cup or any other system component could cause component rupture, which could result in serious injury and property damage.

Setting the Cup Air Pressure WARNING

Pressure Relief Procedure

A

M

K

L

To reduce the risk of serious injury, including splash- ing in the eyes or on the skin, always follow this procedure after you stop spraying, when checking or servicing any part of the spray system, before dis- connecting the gun, air regulator, or pressure cup and when removing a pressure cup for refilling or

Fig. 4

7611A

cleaning.

1.Turn off the air supply to the gun.

2.Trigger the gun into a grounded metal waste container to relieve fluid pressure.

3.Place the cup on a table and slowly release the clamp (A) to bleed-off any residual pressure in the cup. See Fig. 4. Be sure to push the clamp lever fully to the clamped position before turning on the air supply to the gun again.

Setting the Cup Air Pressure

1.Pull up the cup regulator adjustment knob lock-ring (L); this allows the knob (K) to turn. See Fig. 4.

2.Set the cup pressure at zero by turning the adjustment knob (K) fully counterclockwise.

3.Slowly turn the adjustment knob (K) clockwise to increase the air pressure to the cup.

4.Push the adjustment knob lock-ring (L) down to lock the cup pressure setting.

Setting the Gun Air Pressure

NOTE: Installing the gun air inlet regulator adds a pressure drop that could limit the air cap pressure.

Set the gun air pressure regulator for the minimum pressure needed to atomize your fluid. See your gun manual for recommended settings.

Spraying Tips

The regulator is not self relieving so if the regulated air pressure setting is causing excessive fluid flow, follow these steps.

1.Pull up the cup regulator adjustment knob lock-ring

(L). See Fig. 4.

2.Turn the adjustment knob (K) counterclockwise.

3.Trigger the gun into a grounded metal waste container until cup pressure is lowered.

4.Turn the adjustment knob (K) clockwise until you obtain the desired lower pressure setting.

5.Push down the adjustment knob lock-ring (L).

Setting the Gun Air Pressure CAUTION

Do not restrict the fluid flow by continuously spraying with the gun’s fluid adjustment knob (M) turned in (clockwise) as this will cause excessive abrasive wear on the fluid needle and trigger/air valve shaft.

To restrict the fluid flow, lower the cup pressure or use a smaller size needle/nozzle set and air cap combina- tion.

If the cup pressure must be below 1.0 psi (0.07 bar) to achieve the desired fluid flow, a smaller needle/nozzle size is recommended.

4 308791

Image 4
Contents Instructions - Parts List Important Safety InstructionsSingle Air Regulator Double Air RegulatorTable of Contents SetupInstall the Elbow Fitting and Tubing Part No. 239802, 239803, and 245181 Install the Gun on the Cup308791 7611A7612A 7623ASetting the Cup Air Pressure Setting the Gun Air PressurePressure Relief Procedure OperationOptional Gun Air Regulator Maintenance 1. Follow the Pressure Relief Procedure Warning on pageDisconnect the Gun and Air Regulator from the Cup Remove the Cup LidUse Only Genuine Graco Parts and Accessories Single Air Regulator Assembly Part No. 235375, Series BSee parts list at right See parts list aboveDouble Air Regulator Assembly Part No. 235376, Series B See parts list belowSee parts list, page Double Air Regulator Pressure Cup KitRemote Air Regulator Assembly Remote Single Air RegulatorPressure Cup Kit Part No. 236142, Series BTechnical Data WeightWeight without gun Single Air Regulator Pressure Cup Kit, Part No. 239802 andAccessories Spray Gun Air Regulator Assembly100 psi 7 bar Maximum Outlet Pressure 150 psi 10 bar Maximum Inlet PressureGraco Standard Warranty Graco InformationFOR GRACO CANADA CUSTOMERS Graco reserves the right to make changes at any time without notice