5.Span setting mode – allows you to adjust the system ON/OFF
cycle rate. The default setting is 2 (the system cycles ON or OFF when the temperature is within 1o F (0.5o C) above and below the set temperature.) The span setting can be adjusted if your system is cycling too fast or too slowly.
Press and hold both the Up and Down buttons until the word SPAN appears. Use the Up or Down button to adjust the span setting.
(Up will increase your cycle time by allowing the system to run longer; Down will decrease your cycle time by causing the system to run for a shorter length of time.)
Span settings remain the same for HEAT and COOL system settings. When batteries are installed, or the unit is RESET, the span cycle will revert to 2.