required. Heating and cooling set temperatures may not be adjusted until heating or cooling is necessary, or one of these modes is manually selected by pressing and releasing both arrow keys at the same time.

You can force heating or cooling to be the active mode by pressing and releasing both arrow keys at the same time until the desired mode is indicated. After, the unit will then switch modes as necessary to control tempera- ture.

4.1.4.4 HEATING

Press the MODE button repeatedly until the word HEAT is shown along the top of the display. The unit is in HEAT mode ready to control your heating system.

Press temperature UP or DOWN keys until your desired temperature is displayed in the HEAT SET area of the display.

While heating is active, a flame icon will flash above the HEAT SET temperature. If a second stage of heat is called for the flashing rate increases.

4.1.4.5 COOLING

Press the MODE button repeatedly until the word COOL is shown along the top of the display. The unit is in Cool mode ready to control your air conditioner.

Press temperature UP or DOWN keys until your desired temperature is displayed in the COOL SET area of the display.

While cooling is active, a snowflake icon will flash above the COOL SET temperature. If a second stage of heat is called for the flashing rate increases.

4.1.4.6 OFF

Press the MODE button repeatedly until the display indicates that the unit is in OFF.

Heating and cooling will be disabled.

Periods programmed to maintain a minimum fan run time will continue do so.

4.1.5 DISPLAY ILLUMINATION

Press the light bulb button to illuminate the display. Pressing other buttons will keep the display illuminated until no button has been pressed for approximately 20 seconds.

4.2. USER SETUP MENU

User selectable options are available from the User Setup Menu. To access the User Setup Menu press the Setup button. All settings, their choices and default values are given in the USER SETUP MENU:.

4.2.1 ACCESS AND NAVIGATE USER SETUP MENU

To scroll through the User Setup Menu one item at a time, momentarily press Setup Button.

Selections can be changed by pressing the UP/DOWN button.

Moving from one menu item to the next and accept- ance of changes is done by pressing the NEXT button.

All changes become effective when the unit exits the User Setup mode.

The User Setup mode will be exited when the Setup

button is pressed again, or if no other keys are pressed for 20 seconds.

4.2.2 KEYBOARD LOCK

Two types of Keyboard locks allow owners/operators to prevent unauthorized changes to the thermostats set- tings. The two types of locks are full and partial. When the thermostat is locked, a three digit code is set. That code must be reentered before locked settings can be changed without performing a software reset off the unit.

Entering a code toggles the selected lock on or off. While a lock is effective, a padlock is shown near the lower right corner of the screen.

4.2.2.1 PARTIAL KEYBOARD LOCK

A partial lock allows other users to adjust only the tem- perature set point to values at or between the Maximum Heat Setting and Minimum Cool Settings.

4.2.2.2 FULL KEYBOARD LOCK

A full lock disables all the keys except the Setup button on the front, and the S/W Reset button on the rear. Pressing the S/W Reset button will rewrite all settings and programs to their default values.

4.2.2.3SETTING THE LOCK 1. Press SETUP.

2. Select Full or Partial.

3. Press NEXT.

4. Set code one digit at a time. Press NEXT after each digit.

5. When NEXT is pressed after the third digit has been entered, the unit will be appropriately locked.

4.2.2.4CLEARING A LOCK

1.Press SETUP.

2.Enter code one digit at a time. Press NEXT after each digit.

3.When NEXT is pressed after the third digit has been entered, the unit will be unlocked if the correct code was entered.

If you have forgotten the code, your thermostat may be unlocked by pressing the Software Reset button on the rear of the unit's circuit board. This will restore the unit to its default settings and it will likely need to be reconfig- ured to control your HVAC system.

4.2.2.5 CHANGING THE LOCK CODE

1.Press SETUP.

2.Select NEW CODE.

3.Press NEXT.

4.Enter old code one digit at a time. Press NEXT after each digit.

5.Enter new code one digit at a time. Press NEXT after each digit.

6.When NEXT is pressed after the new third digit has been entered, the new code will be effective.

4.2.3 BEEP

This option allows the audible feedback tone (Beep) to be enabled or disabled.

12

Image 12 Contents
PSP722E Heat Stages COOLING/COMPRESSOR StagesElectrical Ratings Tools RequiredWiring RH This terminal provides power to the heating terminalsRemoval of OLD Unit MountingSpecial Wiring Notes Common Wiring OptionsFreeze Protection Single Stage Heating System Label Cross ReferenceHeat FAN Control = GAS XfmrGAS Valve AC LineFAN GAS Valve AC Line= Electric FAN CompressorNot Both Heat Stages OmittedCompressor AUX HeatInstall Batteries Installer SetupAccess and Navigate Installer Setup Menu Heat Pump Lockout TemperatureHeat FAN on Delay Heat FAN OFF DelayCool FAN on Delay Cool FAN OFF DelayCompleting Your Installation Temperature AdjustmentChanging Other Settings Default ProgramUser Setup Menu Display IlluminationKeyboard Lock Partial Keyboard LockMaximum Heat Setting Minimum Cool SettingSmart Recovery Clock FormatHardware Reset H/W Reset Software Reset S/W ResetVacation Hold AIR FilterIng the settings for that day ProgrammingWeekend Programming Battery Installation Copy ProgrammingAlkaline Batteries Only Staging