Features and Benefits

The primary advantage of Trane’s zoning systems is that they are completely integrated systems with Trane’s unitary equipment. Another benefit is that these systems are so simple to install, operate and service, that contractors and installers can take advantage of the delivered concept versus the applied world of design, engineering, and programming. For more information, refer to the table below which describes and compares the features and benefits of Trane’s newest changeover-bypass VAV offering to the existing product.

Product Changes at a Glance

VariTrac II

New VariTrac III

 

 

CCP

CCP with 3 piece enclosure design and optional Operator Display

 

 

Optional relay board with installation kit

Quick snap-in optional relay board with easy to wire terminal strip

 

 

Duct mounted pressure and temperature sensors hard

Communicating sensor assembly including a UCM 4 with integral

wired back to the CCP

temperature and pressure sensor, and output to the bypass damper(s)

 

 

Bypass damper hardwired back to the CCP

Bypass damper with factory installed wiring harness for plug-in connection

 

to communicating sensor assembly

 

 

16 zones

24 zones

 

 

Zone dampers with UCM 3 boards

Zone dampers with UCM 4 boards with:

 

Zone occupancy sensor input

 

Zone CO2 sensor input

 

 

Round zone damper sizes:

Added new rectangular zone dampers in sizes:

6”, 8”, 10”, 12”, 14”, and 16”

8x12, 8x14, 8x16, 10x16, 10x20, 14x18

 

 

Comm 4 communications to the zone dampers

Same Comm 4 communications to the zone dampers for reliable

 

operation and backward compatibility

 

 

Comm 3 communications to Tracker

Supports Comm 5 communications to the new Tracker Version 10 panel

 

 

PC edit terminal required for interfacing with the

Optional touch-screen operator display with built in 7-day time clock .

system (HyperTerminal)

Windows based PC software.

 

 

Round bypass damper sizes:

Bypass dampers now come with factory installed wiring harness for plug-

6”, 8”, 10”, and 12”

in connection to communicating sensor assembly

Rectangular bypass damper sizes:

 

14x12, 16x16, 20x20, 30x20

 

 

 

Manual analog zone sensors only

Digital display zone temperature sensor

 

 

Not applicable

Zone occupancy sensor

 

 

Not applicable

Zone CO2 sensor

 

Duct mount CO2 sensor

 

 

Pressure independent boxes

Ability to use pressure independent boxes

 

 

Add local heat

Ability to add local heat

 

 

6

VAV-SLM002-EN

Image 6
Contents Marketing Guide VariTrac History Contents Why Changeover-Bypass VAV IntroductionDelivered Systems Concept Features and Benefits Product Changes at a GlanceHardware Overview Central Control Panel EnclosureVariTrac Function Overview Digital Display Zone SensorSupply Air Tempering Application Considerations for Changeover-Bypass-VAV Customer Identification Building OwnersConsulting Engineers Contractors Trane Sales ForceSelling Changeover-Bypass-VAV Systems CompetitionVAV-SLM002-EN VAV-SLM002-EN Literature Order Number