Trane TCONT401AN21MA Features, Calibrate Outdoor Temperature, Comfort Information Drawer

Page 9

Features

(cont-)

Page - 16

Pub. No. 22-5206-01

Filter/OD

Page - 9

Pub. No. 22-5206-01

Calibrate Outdoor Temperature

This option allows calibration (or deliberate miscalibration) of the outdoor temperature sensor. The selected number is number of degrees, plus or minus, which will be added to actual temperature. The number can range between + 5 and - 5 degrees in 1/2 degree incre- ments. Factory default is 0. This adjusted value will be used and displayed as actual tempera- ture. For example, if 2 is selected, 72 degrees actual will read 74 degrees.

Comfort Information Drawer

The drawer attached to the mounting base of the control is designed to provide a convenient location for the user to locate their local servicer. A standard business card can be folded and inserted into the slot on the drawer to remind the User whom to call when service is re- quired.

FILTER/OD

Filter/OD - If you press and hold the filter/OD keypad button for several seconds, the display changes to the Quick Setup option for the filter timer. Use the UP or DOWN arrow keypad buttons to change the timer setting if desired, 1 - 180 days.

NOTE: Setting to 0 will disable filter timer.

- Press the filter/OD button again to return to normal display or just wait a few seconds and the display will return on its own.

Image 9 Contents
XR401 Comfort Control Table Of Contents Introduction WarrantyMode Keypad FunctionsUP / Down Arrow Trouble ShootingFAN User Setup OptionsFILTER/OD Keypad NavigationUser Defined Options and Factory Default Settings See , Factory Default SettingsFeatures Calibrate Outdoor TemperatureComfort Information Drawer Wait Indicator Service IndicatorCalibrate Indoor Temperature Energy SavingsFilter Reminder Default Factory SettingsSetpoint Deadband Auto ChangeoverBacklit Display & Keys Cooling Droop