10
PG 10
Congratulations, you have successfully installed your unit. Please proceed to the OPERATING Guide to initialize the
IMPORTANT: After you have labeled and connected your wires, and followed the correct HVAC
LS-90 Features
SAVE ENERGY
HVAC STATUS
NORMAL |
|
|
$0. | FAN |
|
05 KWH | 12:30pm | |
|
| WED |
| o | TARGET |
| F | 77 |
|
| o |
|
| TEMP |
|
| HUMID |
Power |
| 23% |
| HEAT | |
Status | Normal $. | |
| 05/kWh |
MENU
This thermostat can be used with all 24VAC and millivolt (24VAC external power) heating and cooling systems. It
cannot be used with line voltage systems. This thermostat is digital and your desired heat or cool temperatures can easily be set on the large touch screen with the +/- buttons. A minimum 4 minute off time protects heating and cooling compressors from damage. This thermostat uses a new technique called sequential staging for more comfort with faster reaction to requested temperature changes.
24VAC is Required -
This thermostat must be run on the HVAC systems 24VAC (C wire) or external 24VAC transformer connected to the C and RH terminals. The 24VAC “C” wire is the other side of the 24VAC heating transformer and can be found where the other thermostat wires connect at the wall or at the furnace. Do not use the common or ground side of the line voltage.
11
Calibration - |
| Calibrate controls | ||||
Your thermostat was accurately calibrated at the |
|
|
|
|
|
|
factory to ±1° F of actual ambient temperature. |
|
|
|
|
|
|
CALIBRATE | 75o |
|
|
| ||
You do have the option, however, to change the |
| |||||
|
| 1 2 :3 0 pmW ED |
| |||
display temperature to match that of a previous | DELTA |
|
|
|
|
|
thermostat, or to match another thermostat |
| o |
|
|
| |
|
|
|
| |||
already in your home, from ±1 - 9°F. | FACTOR |
| ||||
F |
| |||||
To change your Thermostat Calibration: |
|
|
|
|
| |
AC TU AL |
|
|
|
| ||
1. Press MENU and then touch CALIBRATE |
| MENU | ||||
2. Use the + / - buttons to adjust the displayed | TEMP | DISPLAYED TEMP |
| |||
temperature up or down, as desired. | 77. | <CONTRAST 5> BACK> |
|
|
| |
| ||||||
| ||||||
3. The DELTA FACTOR that appears on the |
|
|
|
|
|
|
|
|
|
|
|
| |
screen will also automatically increase or |
|
|
|
|
|
|
decrease for each 1° adjustment. The large display will show the modi�ed temperature reading that will be displayed on the HOME screen in normal operation.
4. Press HOME to return to the Home screen .
LCD Screen CONTRAST can be adjusted.
To change LCD Screen CONTRAST
From the CALIBRATE screen:
1.Select CONTRAST and adjust by touching the
2.Press HOME to return to the Home screen.
PG 11