Trane manual LS-90 Features, 24VAC is Required, To change your Thermostat Calibration

Page 6

10

PG 10

Congratulations, you have successfully installed your unit. Please proceed to the OPERATING Guide to initialize the LS-90.

IMPORTANT: After you have labeled and connected your wires, and followed the correct HVAC set-up, if these check procedures do not operate your system call support at 1-877-602-5028 8am-12am EST.

LS-90 Features

SAVE ENERGY

HVAC STATUS

NORMAL

 

 

$0.

FAN

 

05 KWH

12:30pm

 

 

WED

 

o

TARGET

 

F

77

 

 

o

 

 

TEMP

 

 

HUMID

Power

 

23%

 

HEAT

Status

Normal $.

 

05/kWh

MENU

This thermostat can be used with all 24VAC and millivolt (24VAC external power) heating and cooling systems. It

cannot be used with line voltage systems. This thermostat is digital and your desired heat or cool temperatures can easily be set on the large touch screen with the +/- buttons. A minimum 4 minute off time protects heating and cooling compressors from damage. This thermostat uses a new technique called sequential staging for more comfort with faster reaction to requested temperature changes.

24VAC is Required -

This thermostat must be run on the HVAC systems 24VAC (C wire) or external 24VAC transformer connected to the C and RH terminals. The 24VAC “C” wire is the other side of the 24VAC heating transformer and can be found where the other thermostat wires connect at the wall or at the furnace. Do not use the common or ground side of the line voltage.

11

Calibration -

 

Calibrate controls

Your thermostat was accurately calibrated at the

 

 

 

 

 

 

factory to ±1° F of actual ambient temperature.

 

 

 

 

 

 

CALIBRATE

75o

 

 

 

You do have the option, however, to change the

 

 

 

1 2 :3 0 pmW ED

 

display temperature to match that of a previous

DELTA

 

 

 

 

 

thermostat, or to match another thermostat

 

o

 

 

 

 

 

 

 

already in your home, from ±1 - 9°F.

FACTOR

 

F

 

To change your Thermostat Calibration:

-2

 

 

 

 

 

AC TU AL

 

 

 

 

1. Press MENU and then touch CALIBRATE

 

MENU

2. Use the + / - buttons to adjust the displayed

TEMP

DISPLAYED TEMP

 

temperature up or down, as desired.

77.

<CONTRAST 5> BACK>

 

 

 

 

 

3. The DELTA FACTOR that appears on the

 

 

 

 

 

 

 

 

 

 

 

 

screen will also automatically increase or

 

 

 

 

 

 

decrease for each 1° adjustment. The large display will show the modied temperature reading that will be displayed on the HOME screen in normal operation.

4. Press HOME to return to the Home screen .

LCD Screen CONTRAST can be adjusted.

To change LCD Screen CONTRAST

From the CALIBRATE screen:

1.Select CONTRAST and adjust by touching the on-screen < and > controls for best viewing.

2.Press HOME to return to the Home screen.

PG 11

Image 6
Contents LS-90 Installation Guide System your on NotesTools LocationRemove OLD Unit What wires do you have? Prepare wiresConnect your wires Mount the LS-90 to wall Hvac Set-up on screen menuSET-UP for Normal systems not a heat pump SET-UP for Heat Pump systems Check Hvac systemTouch Heat Pump Calibration LS-90 Features24VAC is Required To change your Thermostat CalibrationDe-Humidifier Wire Reference ChartHumidifier Fresh AirMotor Driven Valves Wire Zoned Hot WaterZoned Systems Reference Solenoid Valves