12
Humidifier -
To use the /6 internal humidistat to control an external humidifier unit, connect it as shown. Connect the H terminal to the control leg of the humidifier relay. This allows H to turn the humidifier ON and Off.
De-Humidifier -
To use the /6 internal humidistat to control an external
PG 12
FOR EXTERNAL HUMIDIFIER or DEHUMIDIFIER USING HVAC SYSTEM's 24VAC
/60
|
|
| RH H or DH | ||||||
FURNACE R |
|
|
|
|
|
|
| To HUMIDIFIER | |
|
|
|
|
|
|
| |||
POWE R | C |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| or | ||
24VAC |
|
|
|
|
|
|
|
|
H or DH RELAY
DEHUMIDIFIER
Fresh Air -
The Fresh Air feature uses the EX relay to control a baffle on a fresh external air source. Connect the 24VAC baffle to C and EX terminals.
FOR FRESH AIR BAFFLE
/6
RH EX
FURNACE R | BAFFLE |
POWER C |
FOR EXTERNAL HUMIDIFIER or DEHUMIDIFIER USING USING 24VAC ADAPTER
/60
RH H or DH
FURNACE R | To HUMIDIFIER | |
POWER C | ||
or | ||
| ||
AC | DEHUMIDIFIER | |
| ||
ADPT | H or DH | |
| RELAY |
13
WIRE REFERENCE CHART
Your Wires R or V or VR RH or 4
RC
W
W2
W3
?
Y
Y2
G or F C or X E
L
T
H
DH
EX
Bor
O
B and O
Lennox Heat Pump
V or VR or R
M or Y
Y or W or W2
F or G
R or O
LS-90 Terminal
RH and RC Single power for HEAT and COOL
RH Power for HEAT (RH not connected to RC jumper clip removed)
RC Power for COOL (RH not connected to RC jumper clip removed )
W Heat control
W2 2nd stage HEAT or heat pump auxiliary heat
W3 3rd stage HEAT or 2nd stage of 2 stage auxiliary heat
A3rd wire for zoned hot water heat (see zoned systems pg14)
YCOOL control or 1st stage compression for heat pump.
Y2 2nd stage COOL control or 2nd stage compression for a heat pump
GFAN control
CCommon 24VAC power (to power thermostat ) NOTE: TRANE uses B for this connection n/a Emergency heat (do not connect, tape off)
n/a System monitor (do not connect, tape off) n/a Outdoor sensor (do not connect, tape off) External Humidifier
External
BHeat pump changeover (cool to heat, powered in heat)
O Heat pump changeover (heat to cool, powered in cool)
IMPORTANT: If there are both B and O wires (Trane pump products) DO NOT CONNECT B to B terminal, connect B to C terminal. If not a Trane product tape off B.
RH Power for HEAT | Trane Products [American Standard] | ||
B | C | ||
Y | |||
W or W1 or X2 | W2 | ||
W2 | |||
|
| ||
G |
|
| |
OX or X2 or C | C | PG 13 | |
|
|