WARNINGS

IMPORTANT: Read this Owner’s Manual carefully and completely before trying to assemble, oper- ate, or service this heater. Im- proper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning.

DANGER: Carbon monoxide poisoning may lead to death!

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning re- semble the flu, with headaches, dizziness, and/or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These include preg- nant women, persons with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.

Make certain you read and understand all Warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.

Use only kerosene or No. 1 fuel oil to avoid risk of fire or explosion. Never use gasoline, naphtha, paint thinners, alco- hol, or other highly flammable fuels.

Fueling

a)Personnel involved with fueling shall be qualified and thoroughly familiar with the manufacturer’s instructions and applicable federal, state, and lo-

cal regulations regarding the safe fueling of heating units.

b)Only the type of fuel specified on the heater's data plate shall be used.

c)All flame, including the pilot light, if any, shall be extinguished and

the heater allowed to cool, prior to fueling.

d)During fueling, all fuel lines and fuel- line connections shall be inspected for leaks. Any leaks shall be repaired prior to returning the heater to service.

e)At no time shall more than one day’s supply of heater fuel be stored in- side a building in the vicinity of the heater. Bulk fuel storage shall be outside the structure.

f)All fuel storage shall be located a minimum of 25 feet from heaters, torches, welding equipment, and similar sources of ignition (excep-

tion: the fuel reservoir integral with the heater unit).

g)Whenever possible, fuel storage shall be confined to areas where floor penetrations do not permit fuel to drip onto or be ignited by a fire at lower elevation.

h)Fuel storage shall be in accordance with the federal, state, or local au- thority having jurisdiction.

Never use heater where gasoline, paint thinner, or other highly flammable va- pors are present.

Follow all local ordinances and codes when using heater.

Heaters used in the vicinity of tarpau- lins, canvas, or similar enclosure ma- terials shall be located a safe distance from such materials. The recommended minimum safe distance is 10 feet. It is further recommended that these enclo- sure materials be of a fire retardant na- ture. These enclosure materials shall be securely fastened to prevent them from igniting or from upsetting the heater due to wind action.

Use only in well-vented areas. Before using heater, provide at least a three- square-foot opening of fresh, outside air for each 100,000 Btu/Hr of rating. This heater produces carbon monox- ide, which is listed by the State of Cali- fornia as a reproductive toxin under Proposition 65.

Use only in places free of flammable vapors or high dust content.

Use only the electrical voltage and fre- quency specified on model plate.

Use only a three-prong, grounded extension cord.

Minimum heater clearances from com- bustibles:

Outlet: 8 Ft.

Sides:

4 Ft.

Top: 4 Ft.

Rear:

4 Ft.

Locate heater on a stable and level sur- face if heater is hot or running or a fire may occur.

When moving or storing heater, keep heater in a level position or fuel spill- age may occur.

Keep children and animals away from heater.

Unplug heater when not in use.

Heater is equipped with a thermostat. Heater may start anytime.

Never use heater in living or sleeping areas.

Never block air inlet (rear) or air outlet (front) of heater.

Never move, handle, refuel, or service a hot, operating, or plugged-in heater.

Never attach duct work to front or rear of heater.

Warning to New York City Residents For Use Only At Construction Sites in accordance with applicable NYC codes under NYCFD certificate of approval #4803, #4899, #4908, #4909, or #4934.

2

103607

Image 2
Contents Portable Forced AIR Heater Safety Information Portable Forced AIR HeaterProduct Identification UnpackingVentilation AssemblyFuels Tools NeededTo Stop Heater Theory OperationTo Start Heater To Restart HeaterSchedule Preventative MaintenanceStoring TRANSPORTING, or Shipping Troubleshooting Observed Fault Possible Cause RemedyUpper Shell Removal Service ProceduresPump Pressure Adjustment FANFuel Filter Fuel ValveSpark Plug NozzleProcedure if Rotor is Binding Pump RotorIllustrated Parts Breakdown RM200TParts List KEY Part Number Description QTYMaintenance Kits Wheels and Handle Parts ListSpecifications Technical ServiceWiring Diagram Accessories Replacement PartsRepair Service Limited WarrantyWarranty Service International

RM200T specifications

Desa RM200T is a cutting-edge machine designed to elevate agricultural efficiency and productivity. This advanced piece of equipment is specifically engineered for farmers and agricultural enterprises seeking robust performance, durability, and modern technology.

One of the key features of the Desa RM200T is its powerful engine, which provides high torque and reliability even under challenging conditions. The engine is designed for fuel efficiency, allowing users to maximize productivity while minimizing operational costs. This feature is particularly important for farmers looking to optimize their resources and achieve better returns on their investments.

The RM200T boasts an ergonomic design, focusing on user comfort and ease of operation. The controls are intuitively placed, enabling operators to handle the machine with minimal training. The spacious cabin is equipped with air conditioning and excellent visibility, ensuring that users can work comfortably and efficiently for extended periods.

In terms of technology, the Desa RM200T integrates smart farming solutions. It is equipped with GPS systems for accurate navigation and mapping, allowing for precision agriculture practices. This technological advancement enables farmers to analyze field data effectively, leading to informed decision-making and enhanced crop management.

Another noteworthy characteristic of the RM200T is its versatility. It can adapt to a variety of agricultural tasks, including plowing, tilling, and planting. This multi-functionality makes it an invaluable asset for farmers, allowing them to use one machine for a range of operations, thus saving time and reducing the need for multiple equipment purchases.

The durability of the Desa RM200T is a significant highlight. Built with high-quality materials, it can withstand harsh weather conditions and heavy workloads. Regular maintenance is made easy with accessible components, ensuring that the machine remains in optimal working condition over time.

Furthermore, the RM200T is designed with sustainability in mind. Its fuel-efficient engine and minimal environmental impact align with modern farming practices, which prioritize ecological responsibility.

In summary, the Desa RM200T is a remarkable piece of agricultural machinery characterized by its powerful engine, user-friendly design, advanced technology, versatility, durability, and commitment to sustainability. It positions itself as an essential tool for modern farmers aiming to enhance their productivity and embrace the future of agriculture.