Chromalox PK413-4 specifications Thermostat SUB Assembly Replacement

Page 4

CALIBRATION

DANGER: Calibration will involve exposure of inter- nal control terminals to ambient conditions during some part of the recalibration procedure. Combustible materials which cause hazardous conditions must not be present during recalibra- tion process — otherwise explosion may result.

1.Heat water bath or the equipment in which the control is installed (tank, die, platen or machine) to the selected calibra- tion temperature. The entire sensing bulb and at least one foot of its capillary tube are to be exposed to calibrating tempera- ture. With thermostat energized, allow process or bath to reach setpoint. This is accomplished when thermostat begins cycling action.

2.Compare adjustment knob cut off temperature indication against actual temperature to which sensing bulb is exposed. Figure 15 shows example of a control knob showing a control indication of 250°F when true process temperature measured 230°F. In this example, the control knob must be rotated 20° counterclockwise to bring the 230°F knob marking under the index mark in order to recalibrate the control.

3.Without disturbing the shaft setting, loosen the thermostat knob set-screw and re-align dial setting accordingly. Retighten knob set-screw.

4.Recheck for thermostat operation as per steps 2 and 3 and make further calibration adjustment if indicated.

5.Recheck of thermostat operation following final adjustment completes the calibration procedure.

IMPORTANT: Under no circumstances must the temperature range, and in particular, the maximum temperature setting of con- trol be increased above maximum temperature indicated on control nameplate. Such changes voids U.L. listing of the control.

Thermometer

Load (Tank, vat, die or platen)

Figure 14

Indicated Temp.

True Temp

 

250

 

A

200

 

Figure 15

THERMOSTAT SUB ASSEMBLY REPLACEMENT

1.Before removing enclosure cover, turn thermostat knob to the OFF position (counterclockwise). Place a piece of masking tape over the knob to keep it in the OFF position.

2.Remove the enclosure cover by removing four fastening screws (Figure 5).

3.Remove the white shaft coupler for safe-keeping.

4.Remove the thermostat mounting screws (2).

5.Loosen the capillary-seal retaining cap set screws and then remove the retaining cap.

Note: Do not remove the entire capillary seal fitting from the enclosure.

6.Remove the capillary seals and thermostat from the enclosure.

7.Remove the calibration cap (Figure 1) and insert pin from the old thermostat. Rotate the position of the calibration cap, for use in the next step.

8.With replacement thermostat in the OFF position (shaft complete- ly counterclockwise), install insert pin and calibration cap. Install calibration cap with same orientation as noted in step 7 above.

9.If excess capillary, on old thermostat, had been coiled in enclo- sure, it may be necessary to coil an equal amount on replace- ment thermostat per step 4D mounting instructions.

10.After proper capillary length is obtained on replacement ther- mostat, insert capillary in the enclosure and thru the capillary seal fitting.

11.Recheck for proper capillary length (external to enclosure) and adjust if necessary.

12.Align spacer plate and replacement thermostat to mounting holes in the bottom of enclosure using mounting screws (2 – #10-32 x 3/8 Lg.) to secure thermostat to enclosure.

13.Slide the capillary seals into the capillary fitting making sure the capillary is positioned in the center groove of the seals.

WARNING: If capillary is not located in the cen- ter groove properly, damage to the capillary will result, rendering the thermostat inoperable or unreliable.

14.Replace capillary seal retaining cap and tighten set screws to lock in position.

Note: Per the NEC, all threaded connections in a hazardous environment must be tightened sufficiently to engage five full threads.

15.Rewire replacement thermostat per appropriate wiring dia- grams (Figures 7 thru 11).

16.Replace the white nylon coupling on the calibration cap and enclosure cover per step 7 of the wiring section.

17.Replacement thermostat control should be monitored to insure proper operation. If calibration is required, see the calibration section for instructions.

-4-

Image 4
Contents Installation, Operation Specifications Table aWiring GeneralMounting Sensing BulbCalibration Thermostat SUB Assembly Replacement Renewal Parts Identification Thermostat ModelPart Part NumberLimited Warranty

PK413-4 specifications

The Chromalox PK413-4 is a highly versatile electric heater designed to provide efficient heating solutions in various industrial and commercial applications. Renowned for its durable construction and advanced technology, the PK413-4 is engineered to deliver reliable performance while ensuring safety and compliance with industry standards.

One of the main features of the Chromalox PK413-4 is its modular design, which allows for easy installation and maintenance. The heater's flexibility enables it to be configured for different heating requirements, whether for process heat, air heating, or even freeze protection. This adaptability makes it suitable for use in diverse environments, from manufacturing facilities to food processing plants.

The PK413-4 utilizes robust industrial-grade heating elements made from high-quality materials, ensuring long-lasting operation even in harsh conditions. It boasts a stainless steel sheath, providing excellent resistance to corrosion and enhancing its overall lifespan. This feature is particularly important in industries where exposure to moisture or chemicals is prevalent.

Another significant characteristic of the Chromalox PK413-4 is its energy efficiency. The heater is designed to minimize energy consumption while maximizing heat output. This efficiency not only contributes to cost savings but also promotes environmental sustainability by reducing the carbon footprint associated with energy use.

In terms of technology, the PK413-4 incorporates advanced control systems that allow for precise temperature regulation. Users can easily set and adjust temperature settings, ensuring optimal heating without unnecessary energy expenditure. The integration of digital controls enables real-time monitoring and diagnostics, making it easier for operators to maintain ideal operating conditions.

Safety features are paramount in the PK413-4's design. It includes built-in over-temperature protection and limit controls to prevent overheating and potential hazards. The heater is also designed to comply with various safety regulations and standards, providing peace of mind to users regarding operational safety.

Overall, the Chromalox PK413-4 stands out as a reliable and effective heating solution. Its robust construction, energy efficiency, and advanced control technology make it an ideal choice for a wide range of applications. Whether in harsh industrial settings or sensitive commercial environments, the PK413-4 provides consistent heating performance and durability, making it a trusted choice for engineers and facility managers alike.