Bryant TSTATBBNAC01-C Model Selection and Wiring Diagram Chart, III. Install Thermostat

Page 2

TABLE 1—MODEL SELECTION AND WIRING DIAGRAM CHART

OUTDOOR UNIT

 

 

AIR CONDITIONER

 

HEAT PUMP

 

1 Speed

2 Speed

1 Speed

2 Speed

 

 

1-Stage

 

Model AC

Model 2S

Requires

Requires

Furnace

 

See Fig. 2

See Fig. 8

Dual Fuel Thermostat

Dual Fuel Thermostat

2-Stage

Model AC

 

Model HP

Model 2S

Requires

Requires

Furnace

See Fig. 3

 

See Fig. 5

See Fig. 9

Dual Fuel Thermostat

Dual Fuel Thermostat

Typical Fan Coil

Model AC

 

Model HP

Model 2S

Model HP

Model 2S

See Fig. 4

 

See Fig. 6

See Fig. 10

See Fig. 7

See Fig. 11

 

 

Variable-Speed

Model AC

 

Model HP

Model 2S

Model HP

Model 2S

Fan Coil

 

See Fig. 12

 

See Fig. 13

See Fig. 14

See Fig. 15

See Fig. 16

(FK4D, FV4, 40FK)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

III. INSTALL THERMOSTAT

WARNING: ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury or death.

Before installing thermostat, turn off all power to unit. There may be more than 1 power disconnect.

1.Turn OFF all power to unit.

2.If an existing thermostat is being replaced:

a.Remove existing thermostat from wall.

b.Disconnect wires from existing thermostat, 1 at a time. Be careful not to allow wires to fall back into the wall.

c.As each wire is disconnected, record wire color and terminal marking.

d.Discard or recycle old thermostat.

NOTE: Mercury is a hazardous waste and MUST be disposed of properly.

3.Open thermostat (mounting base) to expose mounting holes. The base can be removed to simplify mounting. Snap apart carefully to separate mounting base from remainder of thermostat.

NOTE: If thermostat will not separate, insert a small screwdriver into top slots for ease of opening.

4.Route thermostat wires through large hole in mounting base. Level mounting base against wall (for aesthetic value only—thermostat need not be leveled for proper operation) and mark wall through 2 mounting holes.

5.Drill two 3/16-in. mounting holes in wall where marked.

6.Secure mounting base to wall with 2 anchors and screws provided, (additional anchoring holes available for more secure mounting if needed) making sure all wires extend through hole in mounting base.

7.Adjust length and routing of each wire to reach proper terminal and connector block on mounting base with 1/4 in. extra wire. Strip only 1/4 in. insulation from each wire to prevent adjacent wires from shorting together when con- nected.

8.Match and connect equipment wires to proper terminals of the connector blocks. (See Table 1.)

CAUTION: ELECTRICAL OPERATION HAZARD

Failure to follow this caution may result in equipment damage or improper operation.

Improper wiring or installation may damage the thermo- stat. Check to make sure wiring is correct before proceed- ing with installation or turning on unit.

9.Push any excess wire into wall and against mounting base. Seal hole in wall to prevent air leaks. Leaks can affect operation.

10.Snap case back together.

11.Close thermostat assembly making sure pins on back of circuit board align with sockets in connector.

12.Turn ON power to unit.

NOTE: If a common wire has not been connected, two AA batteries must be used to power the thermostat.

On power up, LCD readout will display AC, HP, A2, or H2 depending on the thermostat model status. See "Power On Check" under "Operational Information" on page 11 for explanation.

IV. SET THERMOSTAT CONFIGURATION

Configuration options are intended to be selected at installation and are normally not modified by the home owner. These options are not discussed in the Homeowner’s Guide and therefore must be made as part of the installation. A special procedure allows entry into the configuration mode. The thermostat will automatically exit this mode if no button is pressed for 3 minutes. While in the configuration mode, up to 14 option choices can be made:

Option 01: Anticipator setting

Option 02: Clean filter setting

Option 03: Fahrenheit or Celsius selection

Option 04: Enable fan (G) on with W/W1 output

Option 05: HP / AC

Option 06: Cooling Lockout (available only if an outdoor air temperature sensor is present)

Option 07: Enable zoning

Option 08: Auxiliary heat lockout temperature adjustment (avail- able only on heat pump systems and if an outdoor air temperature sensor is present)

Option 10: O (reversing valve) ON with Heat or Cool (present on Heat Pump models only)

Option 13: Room temperature offset adjustment

Option 15: Enable AUTO mode

Option 18: Backlight configuration

Option 19: Equipment Present

Option 21: Keypad Lockout

An explanation for each of these and how to enter the configura- tion mode follows.

TO ENTER THE CONFIGURATION MODE:

To enter Configuration Mode, hold the FAN button down for approximately 15 seconds. After the 15 second period, Option 01will appear in the display and the SERVICE icon will be turned on.

NOTE: If the FAN button is pressed again or if no button is pressed for 3 min, the thermostat will exit the configuration mode and return to normal operation. To reenter the configuration mode, the FAN button must be pressed and held for 15 seconds again.

WHILE IN CONFIGURATION MODE:

The display is used to show both the option number and the selection choice within that option.

A. Option 01—Anticipator Adjustment

This adjustment controls the sensitivity and cycle rate of the thermostat. Higher numbers decrease the sensitivity and slow the cycle rate. Lower numbers increase sensitivity and increase cycle

—2—

Image 2
Contents Installation Thermostat Location Safety ConsiderationsInstallation Considerations IntroductionIV. SET Thermostat Configuration Model Selection and Wiring Diagram ChartIII. Install Thermostat Option 01-Anticipator AdjustmentOption 07-Zoning On/Off Configuration Option 02-Clean Filter TimerOption 05 HP and 2S / AC Configuration Option 03-Fahrenheit/Celsius SelectionOption 18 Backlight Configuration Option 13-Room Temperature OffsetOption 15-Auto Mode On/Off Selection Option 08-High Ambient Auxiliary Heat LockoutCheck Thermostat Operation NON-PROGRAMMABLE -C Thermostat Quick Reference Single-Speed Air Conditioner With Typical Fan CoilModel 2S 01-C See notes 2, 4, 6, 10A98455 W2/BSee notes 5, 6, 7, 8, 10 , See note 10A98463 A04011See notes 7 , 10 and 1 A04012A98466 A04013Wiring Diagram Notes Thermostat Troubleshooting Operational InformationNON-PROGRAMMABLE Thermostat Configuration Record A04105

TSTATBBN2S01-C, TSTATBBNAC01-C specifications

The Bryant TSTATBBNAC01-C and TSTATBBN2S01-C are advanced thermostats designed to enhance comfort and energy efficiency in residential and commercial settings. These models stand out for their user-friendly interfaces and a plethora of features aimed at providing precise temperature control and convenience.

One of the main features of both models is their smart programming capability. They allow homeowners to set schedules that adjust heating and cooling according to daily routines. This can lead to significant energy savings, as the systems can optimize temperature settings during periods when a home is unoccupied. Both thermostats are compatible with multi-stage heating and cooling applications, including traditional HVAC systems and heat pumps, making them versatile choices for various climate control setups.

The TSTATBBNAC01-C and their counterpart, the TSTATBBN2S01-C, utilize advanced technology that enables remote access. Users can control their home environment through mobile apps, providing the flexibility to modify settings on the go. This feature is particularly useful for those who want to return to a comfortable home after being away for an extended period.

In terms of compatibility, both thermostats support integration with leading HVAC systems, ensuring a seamless setup for users. They are designed to work with both gas and electric systems, enhancing their functionality across different heating and cooling environments. The connection capabilities extend to Wi-Fi networks, allowing real-time updates and software upgrades that improve performance over time.

The sleek, modern design of the TSTATBBNAC01-C and TSTATBBN2S01-C makes them aesthetically pleasing and easy to read. They feature intuitive touchscreens that display temperature, humidity levels, and other critical information at a glance. This clarity aids users in making informed decisions about their heating and cooling needs.

Energy efficiency is a cornerstone of both thermostat models. By integrating features such as auto-optimization and energy use history, they empower users to reduce their energy consumption. This not only leads to lower utility bills but also contributes to a more sustainable lifestyle.

Overall, the Bryant TSTATBBNAC01-C and TSTATBBN2S01-C thermostats epitomize the modern home’s need for comfort and efficiency. With their advanced programming, remote access capabilities, and sleek designs, they are a worthy investment for anyone looking to enhance their living or working environment.