Bryant A07049, A07048 installation instructions A08128

Page 67

Equipment Control Module

Fan Coil

RVS/Heat Stage 2

Heat Stage 1

Compressor Low

Compressor High

Fan

24VAC Hot Heating 24VAC Hot Cooling Dry Contact 1 Dry Contact 2 24VAC Common Humidify

O/B W2

W/W1

Y1 / W2

Y/Y2

G

Rh

Rc

D1

D2

C

HUM

W3

W2

G

R

C

Aux. Connection

Outdoor Air Temp

Remote Room Sensor

OAT/RRS Com

OAT

RRS

SRTN

Humidifier Solenoid

Valve *

Outdoor Sensor *

Remote Room

Sensor *

A08128

Fig. 23 - Fan Coil Shown with Aux. Connection #2 (Heat Pump/Air Conditioner removed for clarity.)

*Indicates connection may not be required/available.

67

Image 67
Contents Installation Instructions Safety Considerations Table of ContentsIntroduction Power Installation ConsiderationsHumidify Equipment and Connections ModelsDehumidify Equipment and Connections Outdoor Temperature SensorTwo-Piece Thermidistat Control Configuration Remote Indoor Temperature SensorTP-PRH-A Carton Contents InstallationThermidistat Control Location TP-NRH-A Carton ContentsInstall Thermidistat Control Unit Damage Hazard Environmental Hazard Two-Piece InstallationPress Tabs to Remove Backplate Backplate Mounting Control Module Wiring Guide Secure Wires to Terminal Strip Attach Display to Backplate Equipment Control Module on Equipment Standoff Cover on Equipment Control Module Single-Piece Installation Equipment Control Module Reattach Display Module Set Thermidistat Control Configuration Page To Enter Configuration Mode Option 02 Clean Filter Timer Configuration Options -SelectionOption 01 Equipment Type Option 07 Zoning Option 03 Fahrenheit/CentigradeOption 04 Fan G On With W/W1 Option 06 Cooling Lockout Below 55F/13COption 10 Reversing Valve Option 08 Auxiliary Heat Lockout TemperatureOption 12 Smart Recovery Option 11 Deadband Setting Between Heat & CoolOption 13 Room Air Temperature Offset Adjust Option 15 Enable Auto Mode Option 14 Humidity Display Offset AdjustOption 16 Maximum Cycles Per Hour Option 17 Time Between Equipment Stages Option 18 Backlight ConfigurationPage Option 21 Keypad Lockout programmable models only Option 20 Outdoor Air Temperature Offset AdjustmentOption 21 Keypad Lockout non-programmable models only Default is of off Page Option 27 Maximum Heating Setpoint Option 26 Minimum Cooling SetpointOption 28 UV Light Reminder Option 30 Programmable Fan programmable models only Option 29 Humidifier Pad ReminderPage Option 40 Humidify Fan Option 33 Single or Two-Piece InstallationOption 41 Variable Speed Blower Option 43 Intelligent Heat Staging Option 42 Variable Speed Super DehumidificationOption 44 Super Comfort Heat System START-UP and Checkout Option 99 Reset to Factory DefaultsTo Test FAN Energy Star Default Schedule Final SettingsPage Humidification Humidity Control FeaturesHumidification Selections Additional Humidify Comments DehumidificationTo Select Humidification programmable To Select Humidification non-programmablePage Auto Humidity Dehumidify Output and Equipment Connections Additional Dehumidify CommentsVacation programmable models only Vacation Dehumidification Vacation Setpoints Default ValuesVacation Setpoints Vacation HumidificationOperational Information TimersHeat/Cool Setpoints Desired Temperature Equipment On IndicatorsThree-Minute Minimum on Time Programmable Fan programmable models only Humidify and Dehumidify IndicatorsEmergency Heat Mode Auto ChangeoverError Codes TroubleshootingPage Equipment Configuration Outputs Cool Heat Display to Equipment Control Module Connection Wiring DiagramsFV/FK Fan Coil with 2-Stage Heat Pump Typical Fan Coil with Heat Pump OAT RRS Srtn FV/FK Fan Coil w/2-Stage Air Conditioner Typical Fan Coil with Air Conditioner A08128 FV/FK Fan Coil with 1-Stage Heat Pump Typical Fan Coil Heating Only Thermidistat Control w/Dry Contact Control for Fan Run Time FV/FK Fan Coil with 1-Stage Air Conditioner Typical Fan Coil Cooling Only Variable Speed/Multi-Stage Furnace with 2-Stage Heat Pump Single-Stage Furnace with Heat Pump Hybrid Heat Variable Speed/Multi-Stage Furnace w/2-Stage Air Conditioner Single-Stage Furnace with Air Conditioner Variable Speed/Multi-Stage Furnace w/Single-Stage Heat Pump Single-Stage Furnace Heating Only A08140 Single-stage Furnace with Air Conditioner and Split Power Mode Settings Thermidistat Control Configuration RecordConfiguration Options Configuration Options Catalog No TP---PRH---3SI

A07048, A07049 specifications

The Bryant A07049 and A07048 are notable entries in the line of ductless mini-split systems designed for efficient heating and cooling. These models are well-regarded for their robust performance and innovative features that cater to both residential and light commercial applications.

One of the main features of the Bryant A07049 and A07048 is their advanced inverter technology. This technology allows the units to modulate their compressor speed, resulting in a more consistent indoor temperature. By adjusting cooling or heating output based on real-time demand, the units enhance energy efficiency while providing quiet operation and improved comfort.

The cooling capacity of the Bryant A07049 is rated at 7,000 BTUs, making it suitable for medium-sized rooms, whereas the A07048 has a slightly lower capacity, ideal for smaller spaces. Both models excel in providing rapid temperature control, allowing users to enjoy their desired environment swiftly. The quiet operation is a significant advantage, with sound levels as low as 24 decibels, making them perfect for bedrooms, offices, or other noise-sensitive environments.

Installation flexibility is another remarkable characteristic of the Bryant A07049 and A07048. Their ductless design eliminates the need for extensive ductwork, simplifying installation processes. Both models come with easy-mount wall brackets, and the refrigerant lines can be run through a small, discreet opening in the wall, maintaining the aesthetic appeal of the living space.

Energy efficiency is a standout feature of these models, boasting high Seasonal Energy Efficiency Ratio (SEER) ratings. This high-efficiency operation not only reduces energy bills but also minimizes environmental impact. Additionally, both models include a built-in programmable thermostat that allows users to schedule their heating and cooling preferences, enhancing convenience and further optimizing energy use.

The Bryant A07049 and A07048 also feature a multi-stage filtration system. This advanced filtration captures dust, allergens, and other particulate matter, promoting cleaner air circulation which is particularly beneficial for those with allergies or respiratory conditions.

In summary, the Bryant A07049 and A07048 mini-split systems deliver versatility, energy efficiency, and user-friendly operation. Their modern design, quiet performance, and advanced technologies make them excellent choices for individuals or businesses looking to enhance comfort while being mindful of energy consumption. Whether used for supplementary heating or cooling, these units are engineered to meet a variety of climate control needs effectively.