Aprilaire 8910 installation instructions Installation

Page 2

Installation

Thermostat Installation location recommendations

Installation

Thermostat Wiring

Thermostat should be mounted:

On an interior wall, in a frequently occupied space.

Approximately 5‘ above floor.

At least 18” from outside wall.

Thermostat can be mounted to a vertical junction box.

Thermostat mounting

Do not mount thermostat:

Behind doors, in corners or other dead air spaces.

In direct sunlight, near lighting fixtures, or other appliances that give off heat..

On an outside or unconditioned area wall.

In the flow of a supply register, in stairwells, or near outside doors..

On a wall with concealed pipes or ductwork.

Wire specifications:

 

 

 

 

 

18-24 gauge thermostat wire

 

 

 

 

 

Installation notes:

1

2

3

T1

T2

• Ensure power at the HVAC equipment is off.

 

 

 

 

 

Loosen screw terminals, insert stripped wire and re-tighten..

Push the excess wire back into the opening and plug the wall opening to prevent drafts.

1 – Connection to terminal 1 at equipment control module 2 – Connection to terminal 2 at equipment control module

1.Remove the rear mounting plate from the thermostat..

2.Pull wires through the opening on the back of the thermostat..

3.Position and level the mounting plate of the thermostat on wall and mark the hole locations with a pencil..

4.Drill 1/4” holes and insert supplied anchors (drywall only).

5.Place mounting plate over anchors, insert and tighten screws.

6. Seal wire entry holes to prevent drafts affecting temperature readings..

3 – Connection to terminal 3 at equipment control module T1 & T2 – Remote temperature sensor (optional)

Remote temperature sensor (optional)

A remote temperature sensor can be used if the thermostat is to be mounted in a concealed location.. A 8051 flush mount or 8053 surface mount remote temperature sensor can be attached to the T1 and T2 terminals and mounted in a recommended area. The remote sensor must be enabled in the installer set-up menu, and once enabled will override the thermostat’s internal temperature sensor..

Equipment Control Module Installation Location Recommendations

Note: Installer must touch a grounded metal object before handling the Equipment Control Module to avoid potential loss of programs due to electrical discharge..

Equipment control module should be mounted:

Do not mount equipment control module:

• In a location where the temperature will not exceed

• On foundation walls or on the HVAC equipment or

140°F (60°C) or drop below 32°F (0°C)..

ductwork.. These locations can cause moisture to

 

condense on the equipment control module..

Equipment Control Module Mounting

The Equipment Control Module has the following features to simplify mounting and wiring and provide for a clean and neat installation..

Six (6) mounting holes. One on each corner and two centered top and bottom. Any combination of these holes may be utilized.. Mount the Equipment Control Module using 2 to 4 #8 screws appropriate for the mounting surface substrate.. (See Figure 2..)

Wires can be routed through the top, bottom, sides or back.

Nylon wire ties can be used to secure wires in 10 places..

Installation Steps

1.Select mounting location..

2.Pull from bottom to remove front cover.. (See Figure 1..)

3.Mount base using 2 to 4 #8

screws (field supplied)..

Figure 1

Figure 2

 

Remote temperature sensor should be mounted:

On an interior wall, in a frequently occupied space..

Approximately 5‘ above floor.

At least 18” from outside wall.

Using less than 300’ of wire.

Do not mount remote sensor:

Behind doors, in corners or other dead air spaces..

In direct sunlight, near lighting fixtures, or other appliances that give off heat..

On an outside or unconditioned area wall.

In the flow of a supply register, in stairwells, or near outside doors..

On a wall with concealed pipes or ductwork.

Near 120 VAC lines.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

T1

T2

 

 

 

 

 

 

 

2

3

Image 2
Contents Safety Installation Instructions Table of contentsInstallation Outdoor temperature sensor should be mounted Equipment Control Module WiringOutdoor temperature sensor Optional wireless Outdoor temperature sensorC can be Powered from Return Air Temperature Sensor OptionalLeaving Air Temperature Sensor Optional Powered 24VACIndoor Air Quality Wiring Diagrams ThermostatEquipment Type Selection Switch SW1 Power & Reset optionsSetup & Testing Change System SettingsHvac Installer System Settings Table Humidifier System Settings Table Indoor Air Quality System SettingS TablesAir Cleaning System Settings Table Dehumidifier System Settings TableSystem test menu Ventilation System Settings TableHow to enter the system test menu System Test StepsSystem test Tables AuxMain Menu Quick Reference to controls & DisplayHome Screen Y3/OHome Comfort Control Features TroubleshootingError Codes Electrical SpecificationsEnvironment
Related manuals
Manual 19 pages 635 b

8910 specifications

The Aprilaire 8910 is a state-of-the-art thermostat designed to provide homeowners with precise control over their indoor climate. This smart thermostat is equipped with advanced features that enhance comfort while promoting energy efficiency.

One of the standout features of the Aprilaire 8910 is its intuitive touchscreen interface. The large, easy-to-read display allows users to navigate through a variety of settings with ease. The touchscreen is responsive and provides a seamless user experience, making it simple to adjust temperature settings or program schedules.

The Aprilaire 8910 supports both heating and cooling systems, offering flexibility for homeowners with diverse HVAC setups. It is compatible with forced air, heat pump, and radiant systems, as well as multi-stage heating and cooling setups, making it a versatile option for any home.

One of the key technologies integrated into the Aprilaire 8910 is its ability to manage humidity levels. The thermostat works in conjunction with whole-home humidifiers and dehumidifiers, allowing users to maintain optimal humidity levels for health and comfort. This feature is particularly beneficial in climates where humidity fluctuations can lead to discomfort or damage to home interiors.

The 8910 also boasts Wi-Fi connectivity, enabling remote access and control through a smartphone app. This feature allows homeowners to monitor and adjust their home's temperature and humidity levels from anywhere, ensuring comfort upon returning home. The app provides real-time updates and alerts, helping users stay informed about their HVAC system’s performance.

Another notable characteristic of the Aprilaire 8910 is its energy-saving capabilities. The thermostat offers programmable and adaptive scheduling options, allowing users to set different temperature schedules for weekdays and weekends. This reduces energy consumption and helps lower utility bills, all while maintaining a comfortable living environment.

With a sleek design and high-quality build, the Aprilaire 8910 is not only functional but also aesthetically pleasing. It can blend seamlessly with any home decor, making it an attractive addition to any wall.

In summary, the Aprilaire 8910 is a sophisticated thermostat that combines user-friendly technology with energy-efficient features. Its touchscreen interface, humidity control, Wi-Fi connectivity, and energy-saving programming make it a top choice for homeowners seeking ultimate comfort and convenience in climate control.