Aprilaire Model 8570 installation instructions Press the Menu button

Page 39

7.MONITORS – AIR FILTER, SERVICE HUMIDIFIER, UV LAMP, SERVICE HVAC

The thermostat monitors time and can display scheduled reminders for the user to service their humidifier, change their filter and UV lamps, and to remind the user to schedule an HVAC system maintenance check. All monitors are strictly time based, so setting a filter monitor to three months will result in the change reminder being displayed in three months, regardless of how much the HVAC system has run in that period. All monitors can also be turned off for installations where one or more of the components may not be installed. When the thermostat has verified that a monitor setting has been reached, a message is displayed on the thermostat (at the message center location where date and time are normally displayed) and the label for the multi-function button normally labeled INFO changes to CALL DEALER.

To set humidifier, filter, UV and HVAC service reminder schedules:

1.Press the MENU button.

2.Use ▲ or ▼ button to highlight SETTINGS, then press the SELECT button. Press the BACK button to cancel.

3.Use ▲ or ▼ button to highlight MONITORS, then press SELECT. Press BACK to cancel.

4.Use ▲ or ▼ button to highlight the monitor you wish to set (AIR FILTER, SERVICE HUMIDIFIER, UV LAMP or SERVICE HVAC) then press the SELECT button. Press the BACK button to cancel.

5.Use ▲ or ▼ button to highlight the amount of time you wish to set then press the SELECT button. Press the BACK button to cancel.

6.Pressing the SELECT button, after setting the schedule, takes you back to the MONITORS screen.

To set additional reminder schedules return to step 3.

To finish, press the BACK button three times to return to normal operation.

Important: When an AHC is installed with the thermostat, either directly or as part of a Model 6504 Intelligent Zone System, the service humidifier monitor will automatically be set to AUTO. AUTO is not a choice unless an AHC is present. Set to AUTO, the AHC will initiate “service humidifier” based on humidifier type and run time.

- 35 -

Image 39
Contents Instructions Table of Contents Heat Pumps Only Thermostat StartupSafety Instructions Model 8570 Specifications Single-Stage Heat Pump Two-Stage Heat Pump Wire RequirementsTwo-Stage Furnace/AC Radiant 1st Stage HeatKeep the thermostat 18 from an outside wall Select a Mounting LocationOpen the Thermostat Mount the Thermostat Base to the Wall AHC Set to HP when installed with heat pumps Run a cable with the correct number of wires Wire the Thermostat to the Hvac EquipmentDiagram 1 Single-Stage Furnace and AC Diagram 2 Two-Stage Furnace and AC Diagram 3 Two-Stage Roof Top Unit Diagram 4 Boiler with AC Page Diagram 6 Single-Stage Heat Pump Diagram 7 Two-Stage Heat Pump Mount above anticipated snow line Mount the outdoor temperature sensor see Figure85.4 230.6163.8 117.6IDS ODT CIR GND Mount the AHC and its outdoor temperature sensor Optional Install AN Automatic Humidifier Control AHC+ I- R C H ODT Mount the indoor temperature sensor IDS ODT CIR GND Thermostat Startup Stand Alone Applications From the Main Screen, press the Info button Check FAN OperationTroubleshooting AHC Connection Check Heating Operation Troubleshooting Heating Operation Troubleshooting Cooling Operation Thermostat does not call for coolingTo Cool and make a call for cooling To Emergency Heat and make a call for heat Check Emergency Heat Operation Heat Pumps OnlyDifferential Customize the Application SettingsProgressive Recovery Display will show the ADV. Settings MenuOffset Range is 0F to 40F Balance Points Heat Pumps onlyInput Dealer Contact Information To delete a character, press the Back buttonTo delete a number, press the Back button Blower Extension for Humidity Control Press the Menu button DP #10006198 B2203358A BOX 1467 MADISON, WI