Aube Technologies TH104 installation instructions Nstallati on, Connect the thermostat

Page 1

 

 

 

 

TH1 04

 

 

Installation Instructions and Owner￿ s Guide

 

To set the day

FAN: displayed when

Current time

SETPOINT:

 

To set the

 

time

conventional temperature

and day

displayed when

 

To set the

control is selected

 

viewing or

 

 

 

setting the

 

minutes

 

 

temperature

 

 

Heating

 

TIME: displayed

 

To access

indicators

 

 

programming mode

 

 

when time needs

 

 

 

to be adjusted

 

and view programs

 

 

 

 

 

 

 

 

Room

 

LP: displayed

 

 

temperature

 

 

To exit a function

 

during a power

 

 

 

 

 

 

 

failure

 

 

Current program

 

 

 

MODE: to select the

number when the

 

 

 

desired operating mode

Automatic mode

 

Current program

 

 

is active

 

number when

 

Temperature

 

 

Econo schedule

 

 

 

is active

 

adjustment

 

 

 

 

 

 

RESET:

buttons

Automatic

 

Econo

 

Manual

To reset the

 

mode

mode

 

mode

thermostat

 

 

 

 

 

 

 

I NSTALLATI ON

This thermostat has been designed to control a RESISTIVE load not exceeding 3500 W @ 240 VAC or 1750 W @ 120 VAC, such as electric baseboards, convectors, radiant ceilings, floor heating sys- tems, etc.

It is not compatible with a low voltage controller used by a cen- tral heating system or systems using a contactor or a relay whose current is under 2 A.

TURN OFF POWER TO THE HEATING SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK. Installation should be carried out by an electrician.

This thermostat is designed to be used with a self-pro- tected heating system equipped with linear limit control and circuit breaker.

For a new installation, choose a location about 5 ft. (1.5 m) above the floor, facing the heating system and on an inside wall.

Avoid locations where there are air drafts (top of staircase, air outlet), dead air spots (behind a door), direct sunlight or con- cealed chimneys or stove pipes.

All cables and connections must conform to the local electrical code.

Special CO/ALR solderless connectors must be used when

￿connecting with aluminum conductors.

The wires are not polarized, therefore the connections can be made on either terminal.

PROVIDED PARTS

!One (1) TH104 thermostat

"Two (2) 6-32 mounting screws

#Two (2) solderless connectors

1 ) Connect the thermostat

Connect the rear wires to the power and load using solderless con- nectors for copper wires.

2 WIRES

 

4 WIRES

 

1/4

400-104-000-A

Image 1
Contents Connect the thermostat Nstallati onADJ UST the TI ME and DAY FI RST Power onOpti on S Selection Operati N G ModesProgramming the Econo Mode Using the Econo ModeAutomatic Schedule Econo ScheduleWarranty About Temperature CON TrolTechn I CAL Speci FI Cation S Techn I CAL SupportTH104-SW Procedure Locked Keyboard