can still be programmed, the optional outdoor temperature sensor will work and the heat pump fan will turn on if the FAN button is pressed. To avoid frozen water pipes, DO NOT use the OFF mode for long periods of time during
NOTE: After selecting a new mode, the thermostat initiates a delay of up to 4 minutes to protect the heat pump.
Setting High And Low Balance Points
If your system is installed with the required Model 8041 Remote Outdoor Sensor, the high and low balance points should have been properly set by your contractor.
Heat Pumps operate by extracting energy out of the outdoor air and transferring it to the indoor air. This process is efficient over a wide range of temperatures. However, at low outdoor temperatures there is a point at which it becomes more economical to operate the
To review the set points, press and hold the OUTDOOR button, then press the FAN button. “Hi bP” and its temperature value will appear on the display. Next, press the OUTDOOR button again and “Lo bP” and its temperature value will appear on the display. After approximately 15 seconds the display will return to normal.