If the thermostat does not respond when a button is pushed it may be because the keypad has

been locked. A Lock icon “ “ will appear when pushing any buttons other than the buttons outlined above.

No. 3 – Normal Heat Pump/Add-on Heat Pump. This switch is factory preset (to the OFF position) to operate in the normal heat pump mode. If your heating and cooling system is an Add-on heat pump configuration, your contractor changed the position of this switch to match your equipment. Do not change the position of this switch as it could result in extraordinarily high operating costs.

No. 4 – This switch is not used and must remain in the OFF position.

No. 5 – Free LED 1 with LCD Filter Symbol. When moved to the ON position, this switch turns on a replace Filter icon on the LCD display screen when a 24-volt signal is sent to the LED 1 terminal. If your heat pump has the required controls for automatically determining when to change the air filter, this feature is beneficial. Consult your contractor for further information.

No. 6 – Free LED 2 with LCD Wrench Symbol. When moved to the ON position, this switch turns on a Wrench icon on the LCD display screen when a 24-volt signal is sent to the LED 2 terminal. If your heat pump has the required controls for automatically signaling when a particular problem exists, this feature is beneficial. Consult your contractor for further information.

– 23 –

Image 25
Contents Model Setting Or Changing The Weekend Program For Heating Mode Energy Star Program Information Time Schedule Important Read ALL Instructions Thoroughly Setting Or Changing The Clock110-792B 7/12/01 828 AM Progressive Recovery Setting Or Changing The Program110-792B 7/12/01 828 AM Program Schedule Setting Or Changing The Weekday Program For Heating Mode Event Setting Or Changing Weekend Program For Heating Mode Setting Or Changing Cooling Temperatures Press and release the Program button Mo Tu To Start Running The Program Reviewing Programmed Time Schedules Temperature SettingsThermostat Operation For Best PerformanceAprilaire Model Day Programmable Thermostat Temperature Control Time Control Equipment Control Heating or cooling Setting High And Low Balance Points Optional Settings For Additional Thermostat Features Using The Available Red LED IndicatorsAutomatically returns to the original program 110-792B 7/12/01 828 AM Power to the thermostat must be turned off See Figure Place the cover on Turn the thermostat power back on Cleaning Case Of Power FailureLimited Warranty BOX 1467 MADISON, WI