7.Humidity Setting

7.1 Display

8.2 Manual Deactivation

To deactivate the air exchange mode:

n Press the Hum button until one of the following appears on the

screen.

AUTO: The air exchanger is in humidity control mode (auto-

matic adjustment).

MAN: The air exchanger is in humidity control mode (manual

Appears when dehumidification is disabled because the outdoor temperature is too high

Dehumidifier is On

Appears when the humidity setpoint is displayed

Humidity level

Humidifier is On

Humidity control mode (auto, manual, off or air exchange)

adjustment).

OFF: The air exchanger is Off.

oPress the button to return to normal display.

8.3 Minimum Air Exchange Time

If the controller is configured for a minimum air exchange time every hour and that minimum has not already been attained by the end of the hour, the air exchanger will be activated regardless of the indoor humidity level (see page 8, item 19). Let’s say the minimum time is

7.2 Humidity Adjustment

Manual Adjustment

The humidity level is set by the user (5 to 60%).

nPress the Hum button until MAN appears on the screen.

oPress one of the buttons to adjust the humidity level.

pPress the button.

Automatic Adjustment

The humidity level is set by the controller based on the outdoor tem- perature to prevent ice formation or condensation on the windows while providing enough humidity for your comfort. However, the user can apply an offset (-9 to 9%). For example, the user can enter a negative offset if there is ice formation or condensation on the win- dows.

nPress the Hum button until AUTO appears on the screen. The humidity level set by the controller is also displayed.

oPress one of the buttons to enter or change the offset. p Press the button.

Off

To turn off the humidity control:

n Press the Hum button until OFF appears on the screen.

oPress the button to save and exit the programming.

8.Air Exchange Duration Setting

8.1 Manual Activation

If an air exchanger is connected to the controller, it can be used in either of the following modes:

Humidity control mode (see section 7.2)

Air exchange mode (see below).

In air exchange mode, the air exchanger is activated to circulate air between indoors and outdoors regardless of the indoor humidity level). To activate the air exchange mode:

nPress the Hum button until AIR appears on the screen.

oSet the duration you want the air exchanger to operate using

the buttons. Select 10 - 90 minutes for a specific duration or On for an indefinite length of time.

pPress the button.

set to 10 minutes. If the air exchanger has operated for 7 minutes during a particular hour, it will automatically be activated for another 3 minutes by the end of that hour.

9. Technical Specifications

CT280-3H3C CONTROL MODULE

Power supply: 24 VAC

Current consumption: 150 mA

Maximum load per output: 1 A @ 24 VAC

Short cycle protection: 2 minutes

Control cycles: 2 to 6 per hour

Operating temperature: 0°C to 50°C (32°F to 122°F)

Storage temperature: -20°C to 50°C (-4°F to 122°F)

Humidity conditions: 0 to 95%, non-condensing

Dimensions: 95 x 137 x 30 (3.8 x 5.4 x 1.2 in.)

TH146-P USER CONSOLE

Temperature setpoint range

Heating mode: 5°C to 30°C (40°F to 86°F)

Cooling mode: 15°C to 40°C (59°F to 104°F)

Humidity setpoint range: 5 to 60%

Indoor temperature display range: 0°C to 70°C (32°F to 158°F)

Outdoor temp. display range: -50°C to 70°C (-58°F to 158°F)

Temperature display resolution: 0.5°C (1°F)

Program protection: non-volatile memory

Operating temperature: 0°C to 50°C (32°F to 122°F)

Storage temperature: -20°C to 50°C (-4°F to 122°F)

Humidity conditions: 0 to 95%, non-condensing

Dimensions: 79 x 79 x 24 mm (3.1 x 3.1 x 1 in.)

TH146-P-U

400-280-010-B

5/24/07

11/12

Image 11
Contents Introduction InstallationConfiguration Principles of Operation W3/O/B Wiring TablesWiring Diagram 2H1C Heat Pump New Installation Wiring Diagram 3H2C Heat Pump Add-on Installation Wiring Diagram 3H2C Hvac Hvac Configuration MenuTemperature Setting General SettingUnoccupied Mode Temperature AdjustmentTechnical Specifications Humidity SettingFor more information on our products, visit us at WarrantySupport

TH146-P-U specifications

Aube Technologies has made a significant impact in the world of advanced temperature control systems with the introduction of the TH146-P-U model. This innovative device is designed specifically for technologies such as HVAC systems, providing users with an incredibly versatile temperature control solution for both residential and commercial applications.

One of the standout features of the TH146-P-U is its universal compatibility. It is designed to work seamlessly with a wide range of heating and cooling systems, including electric baseboards, convectors, and even fan-forced heaters. This versatility makes it ideal for homeowners and property managers looking to upgrade their current temperature regulation solutions without the need for extensive modifications or compatibility checks.

The TH146-P-U is equipped with a user-friendly interface that simplifies operation. The large, backlit display ensures readability, whether it's day or night. Users can easily program the thermostat to their desired temperature settings, allowing for customized comfort levels throughout the day. Moreover, a built-in digital timer enables users to schedule heating and cooling cycles according to their lifestyle, promoting energy efficiency and cost savings.

One of the key technologies behind the TH146-P-U is its precision temperature sensing capability. The device utilizes advanced algorithms to gauge the temperature accurately, ensuring that it responds quickly to changes in the room. This feature guarantees optimal comfort while preventing energy waste, as the system will operate only when necessary.

A significant advantage of the TH146-P-U is its energy-saving capabilities. The thermostat features adaptable control strategies that maximize energy efficiency without compromising comfort. By monitoring usage patterns and adjusting operation accordingly, the TH146-P-U can significantly lower energy consumption and provide substantial savings on utility bills.

In addition to its performance features, the TH146-P-U also boasts a sleek, modern design that fits seamlessly into any decor. Its compact size makes it easy to install and integrate into existing systems without taking up valuable space.

Overall, the Aube Technologies TH146-P-U thermostat stands out in the marketplace for its versatility, user-friendly features, energy efficiency, and stylish design. It is a fantastic choice for anyone looking to enhance their indoor climate control while reducing energy costs. With its advanced technology and practical characteristics, the TH146-P-U sets a new standard for modern temperature management solutions.