Aube Technologies TH146-P-U manual General Setting, Temperature Setting

Page 9

TH146-P-U

User’s Guide

Programmable H/C Controller

Time and day setting

Programming

Program day selection

Program clear

Humidity setting Return

Indicator LEDs

Temperature adjustment mode selection

Fan operating mode selection

System operating mode selection

Up/Down buttons

Indicator LEDs

FAULT: System fault

EH: Emergency heat mode

DE: Dual energy

Backlight

The screen is lit for 12 seconds when any button is pressed. However, the screen remains lit while you are configuring the controller.

Day

Clock

Indoor temperature

Indoor humidity

Outdoor temperature

5. General Setting

5.1 Clock and Day Setting

6.Temperature Setting

6.1 Display

nPress Clk. The hour display flashes. o Set the hour using .

p Press Clk. The minute display flashes. q Set the minutes using .

r Press Clk. The day display flashes. s Set the day using .

t Press

 

to return to the normal display.

 

 

5.2 Date Setting

n

Press Clk for 3 seconds to display the year.

o

Set the year using

.

Appears when the temperature setpoint is displayed

Heating is On

Auxiliary heating is On

Temperature adjustment mode (appears when the system is in automatic mode, disappears when it is in manual mode)

Indoor temperature

Cooling is On

System operating mode

Fan operating mode (ap- pears when the fan is in continuous mode, disap- pears when it is in automat- ic mode)

p Press Clk to display the month.

q Set the month using

.

r Press Clk to display the date.

s Set the date using

.

t Press

 

to return to the normal display.

 

 

5.3 Fan Operating Mode

Press the Fan button to select the fan operating mode.

In automatic mode, the fan runs only when heating or cooling is activated. NOTE: For gas-operated HVAC systems, there might be a delay before the fan starts or stops when heating is acti- vated or deactivated.

In continuous mode, the fan runs continuously and the sym- bol is displayed. NOTE: if Smart Fan is enabled, when the con- troller is in periods 2 and 4 of automatic mode and in unoccupied mode, the fan will run only when heating or cooling is activated. The fan will run continuously the rest of the time

The controller normally displays the measured indoor temperature. To view the setpoint, press one of the buttons. The setpoint and the symbol will be displayed for the next 5 seconds.

6.2 System Operating Mode

Press Mode to place the system in one of the following modes:

HEAT The system is in heating mode.

COOL The system is in cooling mode.

The system is in automatic changeover mode. (The system

AUTO switches between heating mode and cooling mode to main- tain the desired temperature.)

OFF The system is off.

The system is in emergency heat mode. Only auxiliary heat-

EHEAT ing is used when there is a call for heat. (This mode applies only when the controller is connected to a heat pump

equipped with auxiliary heating).

TH146-P-U

400-280-010-B

5/24/07

9/12

Image 9
Contents Introduction InstallationConfiguration Principles of Operation W3/O/B Wiring TablesWiring Diagram 2H1C Heat Pump New Installation Wiring Diagram 3H2C Heat Pump Add-on Installation Wiring Diagram 3H2C Hvac Hvac Configuration MenuTemperature Setting General SettingUnoccupied Mode Temperature AdjustmentTechnical Specifications Humidity SettingWarranty SupportFor more information on our products, visit us at

TH146-P-U specifications

Aube Technologies has made a significant impact in the world of advanced temperature control systems with the introduction of the TH146-P-U model. This innovative device is designed specifically for technologies such as HVAC systems, providing users with an incredibly versatile temperature control solution for both residential and commercial applications.

One of the standout features of the TH146-P-U is its universal compatibility. It is designed to work seamlessly with a wide range of heating and cooling systems, including electric baseboards, convectors, and even fan-forced heaters. This versatility makes it ideal for homeowners and property managers looking to upgrade their current temperature regulation solutions without the need for extensive modifications or compatibility checks.

The TH146-P-U is equipped with a user-friendly interface that simplifies operation. The large, backlit display ensures readability, whether it's day or night. Users can easily program the thermostat to their desired temperature settings, allowing for customized comfort levels throughout the day. Moreover, a built-in digital timer enables users to schedule heating and cooling cycles according to their lifestyle, promoting energy efficiency and cost savings.

One of the key technologies behind the TH146-P-U is its precision temperature sensing capability. The device utilizes advanced algorithms to gauge the temperature accurately, ensuring that it responds quickly to changes in the room. This feature guarantees optimal comfort while preventing energy waste, as the system will operate only when necessary.

A significant advantage of the TH146-P-U is its energy-saving capabilities. The thermostat features adaptable control strategies that maximize energy efficiency without compromising comfort. By monitoring usage patterns and adjusting operation accordingly, the TH146-P-U can significantly lower energy consumption and provide substantial savings on utility bills.

In addition to its performance features, the TH146-P-U also boasts a sleek, modern design that fits seamlessly into any decor. Its compact size makes it easy to install and integrate into existing systems without taking up valuable space.

Overall, the Aube Technologies TH146-P-U thermostat stands out in the marketplace for its versatility, user-friendly features, energy efficiency, and stylish design. It is a fantastic choice for anyone looking to enhance their indoor climate control while reducing energy costs. With its advanced technology and practical characteristics, the TH146-P-U sets a new standard for modern temperature management solutions.