Assa 62, 82 manual USE of the UMB Bracket with the Model 34 Magnalock, Solid Glass Door Mounting

Page 11

Rev. A.3, 5/00

Page- 8

FIG. 8: USE OF THE UMB BRACKET WITH THE MODEL 34 MAGNALOCK

NOTE HOW BRACKET CAN BE REVERSED TO COPE WITH DIFFERENT STOP THICKNESSES

 

 

BLADE

 

 

 

 

HEADER

STOP

HEADER

 

STOP

 

 

 

 

 

 

 

 

 

UMB BRACKET

 

 

 

UMB BRACKET

 

 

 

 

 

 

 

DOOR

 

DOOR

 

 

 

 

 

MAGNET

 

 

 

MAGNET

 

 

STRIKE

 

 

STRIKE

ALUMINUM DOOR AND FRAME

ALUMINUM DOOR AND FRAME

WITH BLADE STOP

WITH BLADE STOP

THE TWO LARGER HOLES ARE FOR THE

CABLE EXIT. THE TWO THREADED HOLES

ACCEPT THE MAGNET MOUNTING SCREWS.

THE REMAINING FIVE HOLES ACCEPT

DIFFERENT FASTENER TYPES TO MOUNT

TO DIFFERENT HEADERS.

2.5.3 SOLID GLASS DOOR MOUNTING

The Magnalock is an excellent choice for securing 100% glass doors with no aluminum rail. The magnet is suspended in normal fashion from the header and the difficulty in the installation is mounting the strike plate on the glass door as glass cannot be drilled. This is accomplished by using Securitron's model GDB (or GDBM with metric fasteners) Glass Door Bracket and model AKG Adhesive Kit for Glass (see Figure 7). The GDB bracket will work with either the model 32, model 62, or model 82 Magnalock (but not with the model 34). The bracket is affixed to the glass surface by a special adhesive and the strike screws into the bracket conventionally. The adhesive provides a permanent bond stronger than the holding force of the Magnalock.

Note that we have said "100% glass door". Some doors that appear to be glass are actually laminated with plastic. If the Magnalock with glass door bracket is used on this type of door, it is possible that failure will occur via delamination.

In some cases the header of a glass door is vertical glass. The magnet can be mounted on such a header by using a 3" X 3" aluminum angle bracket (part number HEB-3G). The bracket is glued to the vertical glass header with Securitron's adhesive kit for glass and the magnet is screwed to the bracket.

Image 11
Contents Mounting Procedures for Specific Door Types General Installation on Outswinging DoorGeneral Installation on Inswinging Door Appendix C Considerations for Maximum Physical Security Avoiding Poor Release CharacteristicsRev. A.3, 5/00 Strike Plate Mounting Physical InstallationInstallation Tool KIT SurveyStandard Magnet Dimensions and Assembly Mounting the Magnet Strike Dimensions and AssemblyCollapsing the Blind Nuts Magnet Dimensions General Installation on Inswinging Door with Z BracketMagnalock Mounting Aluminum Door and Frame With Blade Stop UMB-BRACKET for Aluminum and Concrete Filled HeadersSolid Glass Door Mounting USE of the UMB Bracket with the Model 34 MagnalockSteel Header Filled with Concrete or Wood Frame Mounting Double Door MountingWood Frame and Concrete Header Bracket Mounting Techniques for Gates Tamper Proofing the Magnalock USE of Dress CoversStandard Lock Electrical InstallationGeneral Electrical Characteristics Senstat Magnalocks SC Wire Gauge SizingDouble Door Control Switching Double Door Procedure for Status ReportingEmergency Release Magnacare Limited Lifetime WarrantyPatents PROBLEM-- Reduced holding force Appendix a TroubleshootingWire Gauge Resistance/1,000 ft Appendix C Considerations for Maximum Physical Security