Assa DK-26 manual Wiring with Securitrons Touch Sense BAR and Magnalock

Page 24

Rev. A.2, 10/03

Page-21

Put the unit into program mode and enter 8-0 to

SRC

UCD HCD

CONNECT A DOOR

assign this function to the HCD terminal or 8-1

SWITCH WHICH

to assign it to the UCD terminal.

You will see

 

 

OPENS WHEN THE

the two flash confirmation. Then,

exit program

 

 

DOOR OPENS TO

mode.

 

 

 

UCD OR HCD

Finally connect a door switch as

shown in the

 

 

DEPENDING ON WHICH

 

 

COMMAND YOU CHOOSE

drawing to the right and you will see that the door

DOOR SWITCH

 

will always relock immediately when it recloses

 

 

 

 

regardless of how much time is left on the timer.

 

 

 

The feature will operate when the door has been released from the keypad or from the REX input (see Section 3.6). Note that to disable the anti-tailgating feature and return full function to the HCD and UCD terminals, put the unit into program mode and enter 8-4. Note that the DK- 26 supports a more powerful anti-tailgating feature which incorporates an alarm signal through the use of the programmable relay. Read Section 6.4 for details.

7.5 WIRING WITH SECURITRON'S TOUCH SENSE BAR AND MAGNALOCK

The DK-26 is often used with Securitron's Touch Sense Bar and magnetic lock. The following drawing shows wiring for this particular configuration. Note that the REX input is not used. Since touching the bar opens the door in a single motion, you do not want to activate the DK- 26's timer which would only serve to keep the lock released for a longer time, thereby reducing security. Another potentially confusing element is that the Touch Sense Bar is also a powered device which operates most reliably when it is constantly powered. The drawing shows a wiring method that is applicable for either an AC or DC power supply (naturally, the supply voltage must be matched to the lock voltage). Note that a variation of this wiring scheme could be desired if you are using the second pole of the DK-26’s lock control relay to shunt an alarm system (see Section 7.3). You would then want the Touch Bar to operate the DK-26’s lock control relay in double break fashion so that the alarm system is shunted both for entry and exit. Simply follow Figure 9 except also connect the blue and orange wires from the Touch Sensor to terminals SRC and REX on the CPU board (as well as connecting the second pole of the lock control relay to the alarm point as shown in Section 7.3).

FIG. 9: WIRING OF DK-26, TOUCH SENSE BAR AND MAGNALOCK

NOTE: SEE FIG. 2 FOR 12 WIRE KEYPAD CABLE CONNECTIONS

WHITE

IF AC POWER IS BEING USED, CONNECT 12 OR 24 VAC TO

AC IN TERMINALS

IF DC POWER IS BEING USED, CONNECT 12 OR 24 VDC TO

DC IN/OUT TERMINALS. BE SURE TO OBSERVE POLARITY

 

 

AC

 

 

 

 

 

IN F

 

 

DCIN/OUT

 

 

 

 

 

 

+

 

 

 

 

 

 

DC

 

 

 

 

 

 

 

 

+

IN/OUT

 

 

 

 

 

 

 

CPU BOARD

NC1 C1

TOUCH RED SENSOR

GREEN

BLACK

RED

MAGNALOCK

BLACK

POWER SUPPLY VOLTAGE MUST MATCH VOLTAGE OF MAGNALOCK

Image 24
Contents Connecting the Keypad Cable to the CPU Board Adding Other Lock Control SwitchesSetting the Time Range and Toggle Mode 1 Changing the User and PROG. Code from Keypad --PageWiring with Touch Sense BAR and Magnalock Nightlight FunctionPhysical Installation Physical Installation of Keypad Wiring Power SelectionDK-26 Power Consumption Volts Power and Electric Lock WiringOverview of CPU Board AC Lock AC Power Wiring DC Lock with AC PowerDC Lock AC Power Wiring DC Lock with DC PowerDC Lock DC Power Wiring Adding Other Lock Control SwitchesUSE of the F Terminal Adding External Contacts for Fail Safe and Fail Secure Locks REX FunctionDouble Break Wiring for Free Egress TWO Pole Switch Programming Fixed ProgrammingRev. A.2, 10/03 Page-11 Keypad Changeable Programming Changing the User and Program Code from the Keypad Adding Multiple User Codes Masterkey USE of the Hard CodeSubset Codes Deleting CodesChanging LED and Beeper Operation USE of the Programmable Relay Doorbell FunctionDuress Function ANTI-TAMPER Alarm Function Door Prop Alarm FunctionAdditional Hard Wired Options Hardwired Code DisablingNightlight Function Dual PAD OperationAlarm System Shunting Wiring to Shunt Alarm System on DoorANTI-TAILGATING Wiring with Securitrons Touch Sense BAR and Magnalock Wiring of DK-26, Touch Sense BAR and MagnalockMAGNACARE→ Limited Lifetime Warranty Appendix a Command Summary With the Unit in Program Mode Fast Yellow FlashRev. A.2, 10/03 Page-ii PROBLEM-- a key isn’t echoed no beep or LED flash PROBLEM-- Door opens on a short code that wasn’t programmed PROBLEM-- How to check the Keypad