Assa DK-26 manual AC Lock AC Power Wiring, DC Lock with AC Power

Page 8

Rev. A.2, 10/03

Page-5

Note installation of the MOV across the power wires to the lock. The MOV is the small black disk shaped component furnished loose with the DK-26. Its function is to absorb inductive kickback from the lock’s coil. Without the MOV, this kickback voltage will arc over the relay contacts and reduce the switching life of the relay. The arc also creates electronic noise which could occasionally cause the microprocessor to malfunction. The MOV should be spliced into the lock power wires as close to the lock as possible.

FIG. 3: AC LOCK - AC POWER WIRING

TRANSFORMER

12 OR 24 VAC

 

 

AC

 

 

IN

 

 

F

 

 

DC IN

 

 

 

 

+

/OUT

 

NC1 C1 NO1

 

 

AC FAIL SECURE

 

 

 

 

 

MOV

LOCK

3.3.2 DC LOCK WITH AC POWER

For convenience and economy, most DC electric locks can be operated from an AC transformer when the DK-26 is used. Select a transformer of the same voltage as the lock (12 or 24). The CPU board converts the input AC to DC to operate the lock. Make sure the capacity of the transformer is large enough to operate both the DK-26 and the lock and that the transformer is UL listed under the UL 294 standard (to maintain the DK-26 UL listed status). The lock must accept full wave rectified DC power. This is true of most DC locks (including Securitron’s Magnalocks) but some specialty units require regulated DC power. You must operate those as described in the next Section. Note finally that many DC lock installations call for battery backup. To achieve this, you must employ a DC battery backup power supply and also follow the wiring description in Section 3.3.3.

DC locks come in “fail secure” and “fail safe” versions. A fail secure lock is secure when not powered and a fail safe lock is secure when powered. All magnetic locks are fail safe. Figure 4 shows AC power being input to the AC terminals. The DC terminals furnish output power for the lock. DC locks operated in this way must not draw more than 2 Amps. The positive DC terminal connects to the common of relay #1 and either the NO1 terminal (if the lock is fail secure) or the NC1 terminal (if the lock is fail safe) connects to the lock’s positive power input. This is shown in dotted lines. You only connect one of these terminals. Note that some DC locks are polarized and you must connect lock power correctly to positive and negative. Others are not polarized and can be connected either way. Consult the lock instructions.

Note installation of the MOV across the power wires to the lock. The MOV is the black disk shaped component furnished loose with the DK-26. Its function is to absorb inductive kickback from the lock’s coil. Without the MOV, this kickback voltage will arc over the relay contacts and

Image 8
Contents Connecting the Keypad Cable to the CPU Board Adding Other Lock Control SwitchesSetting the Time Range and Toggle Mode 1 Changing the User and PROG. Code from Keypad --PageWiring with Touch Sense BAR and Magnalock Nightlight FunctionPhysical Installation Physical Installation of Keypad Wiring Power SelectionDK-26 Power Consumption Volts Power and Electric Lock WiringOverview of CPU Board AC Lock AC Power Wiring DC Lock with AC PowerDC Lock AC Power Wiring DC Lock with DC PowerUSE of the F Terminal DC Lock DC Power WiringAdding Other Lock Control Switches Adding External Contacts for Fail Safe and Fail Secure Locks REX FunctionDouble Break Wiring for Free Egress TWO Pole Switch Programming Fixed ProgrammingRev. A.2, 10/03 Page-11 Keypad Changeable Programming Changing the User and Program Code from the Keypad Adding Multiple User Codes Masterkey USE of the Hard CodeSubset Codes Deleting CodesChanging LED and Beeper Operation Duress Function USE of the Programmable RelayDoorbell Function ANTI-TAMPER Alarm Function Door Prop Alarm FunctionAdditional Hard Wired Options Hardwired Code DisablingNightlight Function Dual PAD OperationANTI-TAILGATING Alarm System ShuntingWiring to Shunt Alarm System on Door Wiring with Securitrons Touch Sense BAR and Magnalock Wiring of DK-26, Touch Sense BAR and MagnalockMAGNACARE→ Limited Lifetime Warranty Appendix a Command Summary With the Unit in Program Mode Fast Yellow FlashRev. A.2, 10/03 Page-ii PROBLEM-- a key isn’t echoed no beep or LED flash PROBLEM-- Door opens on a short code that wasn’t programmed PROBLEM-- How to check the Keypad

DK-26 specifications

The Assa DK-26 is a state-of-the-art electronic locking system designed to provide enhanced security for a variety of applications, including commercial, institutional, and residential environments. This locking solution is characterized by its robust construction, advanced technology, and user-friendly features, making it a popular choice among security professionals.

One of the standout features of the Assa DK-26 is its innovative design, which combines mechanical and electronic security elements. The locking mechanism utilizes a high-security cylinder, ensuring that unauthorized access is thwarted. This cylinder is key-operated, allowing for traditional key entry while also supporting electronic access control, offering flexibility to users.

The DK-26 is equipped with advanced electronic technologies that enhance its functionality. One of the key technologies integrated into this system is RFID (Radio Frequency Identification). This allows users to gain access using key fobs or cards that contain embedded RFID chips. The system can be programmed to allow or deny access based on time schedules, occupancy status, or individual user credentials, providing a high level of control over who can enter a facility.

Another notable characteristic of the Assa DK-26 is its ability to integrate with various security management systems. This compatibility allows for centralized control and monitoring of multiple locking devices, enabling security personnel to efficiently manage access across an entire building or campus. Additionally, the DK-26 features real-time audit trails, which log all access attempts and can be reviewed for security audits or investigations.

The DK-26 is designed for durability and resilience, featuring weather-resistant materials that make it suitable for both interior and exterior applications. Its sleek and modern aesthetic adds to the appeal for businesses looking to maintain a professional appearance while ensuring optimal security.

Installation of the Assa DK-26 is straightforward, as it can be retrofitted to existing door hardware without requiring extensive modifications. This ease of installation, combined with its reliable performance, makes the DK-26 an intelligent choice for anyone looking to upgrade their locking systems.

In summary, the Assa DK-26 electronic locking system combines high-security mechanical features with advanced electronic technologies, making it a versatile and effective solution for securing a diverse range of environments. Its RFID access capabilities, integration with security management systems, and robust construction make it a standout choice in modern security solutions.