LG Electronics V-C7050NT, V-C7070CT, V-C7070CP, V-C7050HT service manual Switch OFF but Motor Turns

Page 7

3. SWITCH OFF BUT MOTOR TURNS

Poor connection

Repair.

Poor switch

 

Exchange the switch.

 

4. WEAK SUCTION POWER

Low rotation speed

Carbon brush defaced

Motor armature cut

Foreign matters attached to the impeller

Exchange the carbon brush or the motor.

Exchange the motor.

Remove the foreign matters.

Low voltage

Inquire to the power utility company.

Motor turns normally,

but suction power is weak.

Hose and extension wands are clogged with foreign matters.

The slide knob on the handle is opened or the control knob is located on weak position.

The motor filter is clogged.

The exhaust filter is clogged.

Remove the foreign matters in the hose or extension wands.

Close the slide knob by sliding it. Regulate the knob.

Clean the motor filter.

Exchange the exhaust filter.

7

Image 7
Contents Vacuum Cleaner Contents Motor filterAir Cleaner Safety PrecautionsDescription SpecificationsBody Cover Assembly Replacement DisassemblyCheckingcause Solution Trouble ShootingSwitch OFF but Motor Turns Vibration Noises Schematic Diagram Block DiagramSchematic Diagram C7070CT CN2 Circuit DiagramExploded View C7050NT/HT C7070CT/CP 452151 436501 449321 435501 652012 552491 452151 435501 449321 Description Application Remark Replacement Parts ListDAMPER, Assy Appendix Type of Power Cord & Parts NumberColor & Parts Number Memo Memo No FI3816A