TROUBLESHOOTING
For any problems not listed below, call your local distributor or contact our Service Department toll free at
PROBLEM | CAUSE | SSSOLUTION |
|
|
|
Unit does not operate | No power to machine | Plug in the unit; check power at outlet. |
| Switch not turned on | Turn on switch. |
Compressor will not start | Unit needs 5 minutes before restart | Switch off unit, wait 5 minutes before starting. |
| Overload preventing start up | Reduce room temperature below 90° F (32° C). |
Blower wheel not turning | Obstructed blower | Remove obstruction. |
| Loose blower wheel set screw | Tighten Screw. |
|
|
|
Unit operating, but room not dry | Not enough time to dry | Allow more time for drying. |
| Poor air movement in room | Increase airmovement with TurboDryers. |
| Excessive air infiltration | Reduce airflow into the area being dried. |
Unit continuously in defrost | Room temperature too low | Increase room temperature. |
|
|
|
Unit collects little water | Room air is dry | Check humidity with hygrometer. |
| Room temperature too low | Inrease the room temperature. |
| Airflow through unit restricted | check filter and coils, clean if debris. |
Pump does not function | Stuck float valve | Clean float valve shaft. |
|
|
|
SPECIFICATIONS
MODEL | EVOLUTION LGR | CONTROLS | TOUCHPAD |
| F292 |
|
|
TYPE | LOW GRAIN REFRIGERANT | HOUR METER | YES |
HEIGHT | 33.5" (85 CM) | WATER | CENTRIFUGAL |
WIDTH | 20.7" (52.5 CM) | DRAIN HOSE LENGTH | 40 FT (12.2 M) |
DEPTH | 20.7" (52.5 CM) | AIR FILTER | 3M™ HIGH AIRFLOW* |
USE WEIGHT | 92 LB (42 KG) | WHEELS | |
|
|
|
|
WATER REMOVAL AHAM | 70 PINTS/DAY (33 LTR) | HANDLE | COLLAPSIBLE METAL |
| 80° F/20% RH 7 PINTS | HOUSING | ROTOMOLDED |
OPERATING RANGE | 33° - 90° F (1° - 32° C) | POWER 115V | 5.6 AMPS |
COMPRESSOR TYPE | 5,595 BTU ROTARY | CORD LENGTH | 25 FT (7.6 M) |
|
|
|
|
DEFROST TYPE | SAFETY MARKS | UL | |
PROCESS AIR | 160 CFM (272 CMH) |
|
|
7 |