LG Electronics PG-100-2006-VER3 manual Wire Size

Page 11

ART COOL MINI-SPLIT SINGLE ZONE

ELECTRICAL & REFRIGERATION QUICK REFERENCE

Electrical Specifications

 

Type

Model

BTUs

Voltage

Rated Amps

MCA*

MOP**

Art Cool

 

 

 

Indoor

Outdoor

 

 

 

 

 

 

 

 

 

 

 

 

Single Zone

A/C

LA091CNP

9,000

36V DC

115

7.2

15

15

 

A/C

LA121CNP

12,000

36V DC

115

9.3

15

20

 

A/C

LA121CNM

11,500

36V DC

115

10.5

15

20

 

A/C

LA181CNW

18,000

36V DC

230/208

9.8

15

20

 

 

 

 

 

 

 

 

 

 

H/P

LA091HNP

9,000

36V DC

115

7.2

15

20

 

H/P

LA121HNP

12,000

36V DC

115

9.3

15

20

 

H/P

LA121HNM

11,500

36V DC

115

10.5

15

20

All equipment single phase.

NOTE: Please see local electrical codes for proper wire specifications.

*Minimum Circuit Ampacity

**Maximum Overcurrent Protection

Wire Size

Minimum AWG

14-3

Indoor/Outdoor Connecting Cable Minimum AWG

18-4

RefrigefrigerarantLinet Line&FormulaSpecifications***

 

Type

Model

BTUs

Pipe Size

Additional

Max. Pipe

Max.

Art Cool

 

 

 

Liquid

Suction

Refrigerant

Length

Elevation

 

 

 

 

 

 

 

 

 

Single Zone

A/C

LA091CNP

9,000

1/4"

1/2"

0.21 oz./ft.

50'

25'

 

A/C

LA121CNP

12,000

1/4"

1/2"

0.21 oz./ft.

50'

25'

 

A/C

LA121CNM

11,500

1/4"

1/2"

0.21 oz./ft.

50'

25'

 

A/C

LA181CNW

18,000

1/4"

1/2"

0.21 oz./ft.

100'

50'

 

 

 

 

 

 

 

 

 

 

H/P

LA091HNP

9,000

1/4"

1/2"

0.21 oz./ft.

50'

25'

 

H/P

LA121HNP

12,000

1/4"

1/2 "

0.21 oz./ft.

50'

25'

 

H/P

LA121HNM

11,500

1/4"

1/2 "

0.21 oz./ft.

50'

25'

***Each system is pre-charged with enough refrigerant to charge 25 ft. of line and the interior unit.

NOTE: Systems having the outdoor unit mounted above the indoor unit (e.g. basement installations) have the following additional requirement:

For systems with maximum elevation of 25 ft. (see chart above and Figure A), refrigerant lines must be oil trapped between 8 ft. and 16.4 ft. of elevation.

For systems with elevation of greater than 25 ft. (see chart above), refrigerant lines must be oil trapped at least every 16.4 ft. of elevation.

 

OUTDOOR UNIT

OIL TRAP

 

INDOOR UNIT

25' maximum

 

 

8' minimum

 

16.4' maximum

Figure A.

Example: 25 ft. maximum elevation.

9

Image 11
Contents LG Electronics, Hvac Division Product Guide MINI-SPLIT ART COOL, Single Zone Floor Standing & Ceiling CASSETTE, Single Zone Multi Power System. Energy-saving twin Look for these key features throughout the LG lineAvailable styles and finishes ART Cool MINI-SPLIT Single ZoneLA091CNP LA091HNP BTUsLA121CNP LA121HNP Outdoor Dimensions12,000 BTUs LAU121CNM LAU121HNM LA121CNM LA121HNMLAN121CNM LAN121HNM LAU181CNW 18,000 BTUsLA181CNW LAN181CNWWire Size MINI-SPLIT Standard AIR Conditioners Single Zone LSU090CE LSU090HE Standard FeaturesLS090CE LS090HE LSN090CE LSN090HELSU120CE LSU120HE LS120CE LS120HELSN120CE LSN120HE LSU180CE LSU180HE LS180CE LS180HELSN180CE LSN180HE LSU240CE LSU240HE 24,000 BTUsLS240CE LS240HE LSN240CE LSN240HELSU302CE LSU302HE 30,000 BTUsLS302CE LS302HE LSN302CE LSN302HESystem Pipe size Additional TypeBTUs Voltage Rated Indoor Outdoor AmpsRefrigerant line Electrical tape Condenser mounting pad Closed cell insulating tubing for suction lineFlex Multi Split AIR Conditioners Dual Zone & TRI-ZONE LMN120CE 18,000-24,000 BTUs Dual ZoneModel # LMN090CELMAN121HNM Available styles See page 18 for color optionsLMN090HE LMN120HELMN120CE A/C Model Standard LMN120HE H/P Model Standard H x D inches Weight lbs 172.027,000-36,000 BTUs Tri-Zone LMN090CE A/C Model Standard LMN090HE H/P Model StandardH x D inches 41 5/32 44 7/8 17 5/16 Weight lbs 172.0 Each pipe Zone Type Model BTUs Voltage RatedPipe size Additional Type Model BTUs Liquid SuctionDUCT-FREE LFU300CP 28,000 BTUsLF300CP LFN300CPLFN480CE 48,000 BTUsLF480CE Interior Unit Includes Exterior Unit IncludesLCU240CP LC240CPLCN240CP LCU340CP 34,000 BTUsLC340CP LCN340CPType System # BTUs Type System # BTUs Voltage RatedMOP THROUGH-THE-WALL AIR Conditioners LT0810CR LT1010CR LT1030CR LT1210CR LT1230CR LT1430CR Dimensions000-14,000 BTUs System IncludesLT1030HR LT1230HR 10,000-12,000 BTUs10,000 BTUs Cooling & Heating 11,700 BTUs Cooling & HeatingTTW Optional AccessoriesPackaged Terminal AIR Conditioners LP120CED LP150CED 000-15,000 BTUsLP070CED LP120HED LP150HED 12,100 BTUs Cooling & HeatingLP070HED Accessories Type Model # BTUs Voltage Rated