LG Electronics 5CSV2-03A manual Wiring Diagrams, Model No. LV-B1864CL, LV-B2464CL

Page 25

7. Wiring Diagrams

Model No.: LV-B1864CL, LV-B2464CL

Indoor Unit

Outdoor Unit

 

 

 

 

 

TRANS-

THERMISTOR

 

 

CAPACITOR

FORMER

 

 

 

 

 

 

 

 

 

 

BR YL

 

 

CN-TRANS

CN-TH

 

 

 

 

CN-FAN

 

 

 

 

OR

 

 

 

 

 

 

 

 

MAIN PCB

 

 

 

 

RD

RY-L

 

GN/YL

MOTOR

BL

RY-M

ASSY.

 

 

 

BK

RY-H

 

 

 

 

 

 

 

 

 

 

 

DOOR S/W 1

 

 

 

 

GN/YL

 

 

 

 

1,2

STEP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UP/DOWN

 

 

 

 

 

3

FUSE

MOTOR

 

 

 

 

 

 

 

 

 

 

 

4

T3.15A

 

 

 

 

 

 

 

 

 

 

 

 

 

RY-COMP

STEP

 

 

 

 

 

-

MOTOR

 

 

 

 

 

CN-4WAY

CN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BL

 

 

 

 

 

 

 

 

 

 

GN/YL

 

 

CN-DISP

 

 

 

 

 

 

 

 

 

BR

BL

 

WH

 

TERMINAL

 

 

1(L) 2(N)

3

4

 

DISPLAY PCB

 

BLOCK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ASSY.

 

 

 

 

 

 

TO OUTDOOR UNIT

 

 

POWER

 

 

 

 

 

 

 

INPUT

 

 

 

 

 

 

 

Notes:

 

 

 

 

 

 

 

R

BL

 

 

 

 

 

 

 

 

 

COMP. S

RD

H

 

F

YL

 

 

C

 

 

BR

 

 

OR

 

 

 

 

C

 

 

CAPACITOR

 

 

 

 

 

 

 

 

FAN

 

 

 

 

 

MOTOR

 

 

 

 

 

BK

 

 

BR

BL

 

 

 

 

3

4

 

TERMINAL

 

 

 

BLOCK

 

 

 

 

 

TO INDOOR UNIT

RY

RELAY

BL

BLUE

BK

BLACK

BR

BROWN

RD

RED

OR

ORANGE

WH

WHITE

YL

YELLOW

GN/YL

GREEN/YELLOW

Model No.: LV-B1864H(B)L, LV-B2464H(B)L

Indoor Unit

Outdoor Unit

 

 

 

 

 

 

TRANS-

THERMISTOR

CAPACITOR

 

 

FORMER

 

 

 

 

 

 

 

 

BR

YL

 

 

 

CN-TRANS

CN-TH

 

 

 

CN-FAN

 

 

 

 

OR

 

 

 

 

 

 

 

 

MAIN PCB

 

 

 

 

RD

 

RY-L

GN/YL

MOTOR

 

BL

 

RY-M

ASSY.

 

 

 

BK

 

RY-H

 

 

 

 

 

 

 

 

 

 

 

DOOR S/W 1,2

 

 

 

 

GN/YL

 

 

 

 

 

1,2

STEP

 

 

 

 

 

 

 

-UP/DOWN

MOTOR

BR

 

 

 

 

 

3 FUSE

 

 

 

WH

 

 

 

T3.15A

 

 

 

 

 

 

 

 

 

 

 

 

 

RY-COMP

STEP

 

 

 

 

 

MOTOR

BL

 

 

 

 

CN-4WAY

CN

 

 

 

 

 

 

 

 

BK

 

RY-4WAY

 

 

 

 

 

 

 

 

 

 

BL

 

 

RD

 

 

 

 

 

 

 

 

 

 

RT-OUTFAN

CN-DISP

 

 

 

 

 

 

GN/YL

 

 

1(L) 2(N)

3

4

5

6

7

8 TERMINAL

DISPLAY PCB

 

 

 

 

 

 

BLOCK

 

 

 

 

 

 

 

ASSY.

 

POWER

 

 

 

 

 

TO OUTDOOR UNIT

 

INPUT

 

 

 

 

 

 

 

 

Notes:

 

 

 

 

 

 

 

 

 

R

BL

CAPACITOR

 

 

 

 

 

 

 

 

 

COMP. S RD

H

C

F

YL

FAN

 

C

 

 

 

 

OR(BR)

 

 

 

 

 

MOTOR

 

 

 

 

 

 

BK

 

 

 

 

REVERSING

 

 

GN/YL

 

 

 

VALVE

 

 

 

 

BK

BK

BK

 

 

 

 

 

 

 

 

T/B

 

 

 

 

 

 

 

 

BL

BR

 

 

 

 

 

 

 

 

BK

 

BK

 

 

 

 

 

 

 

 

GN/YL

 

3

4

5

6

7

 

TERMINAL

 

BLOCK

 

 

 

 

 

 

GN/YL

 

 

 

 

 

 

 

 

 

TO INDOOR UNIT

 

 

 

RY

RELAY

BL

BLUE

BK

BLACK

BR

BROWN

RD

RED

OR

ORANGE

WH

WHITE

YL

YELLOW

GN/YL

GREEN/YELLOW

24Ceiling & Floor, Ceiling Suspended (50Hz, R22)

Image 25
Contents Ceiling & Floor50Hz, R22 Ceiling Suspended50Hz, R22 LG Electronics Inc General DescriptionCeiling & Floor, Ceiling Suspended 50Hz, R22 Table of Contents Cooling Only Models ListIdentification Rule Model Number NomenclatureFeatures & Benefits List of Functions Air Discharge outlet Airflow Direction control left & right LV-C368KLA01 Features Ceiling SuspendedLV-C488LLA01 LV-H488LLA0 LV-C488LLB0 LV-H608LLA0 LV-C608LLB0 LV-B1864CL LV-B1864HBL LV-B2464CL LV-B2464HBL SpecificationsLV-B2860CL LV-B2860HL LV-C3681CL LV-C3681HL LV-D4881CL LV-D4881HL LV-D6081CL LV-D6081HL LV-H368KLAB0 LV-H488LLAB0 LV-H608LLAB0 LV-C368KLAB0 LV-C488LLAB0 LV-C608LLAB0 LV-C368KLA1 LV-C488LLA1 LV-C608LLA1 Model No. LV-B1864CH/BL, LV-B2464CH/BL, LV-B2860CHL Dimensional DrawingsIndoor Unit Outdoor UnitModel No. LV-C3681CHL, LV-D486081CHL Dimensional Drawings ABC Model No. LV-CH368KLAB0, LV-C368KLA1 LV-CH48608LLAB0, LV-C48608LLA1 Model No. LV-CH48608LLAB0, LV-C48608LLA1Model No. LV-B1864CL, LV-B2464CL Wiring DiagramsModel No. LV-B1864HBL, LV-B2464HBL Model No. LV-B2860HL Model No. LV-B2860CLModel No. LV-C3681CL Model No. LV-C3681HLIndoor Unit Outdoor Unit Model No. LV-D4881CL Model No. LV-D4881HLModel No. LV-D6081CL Model No. LV-D6081HLModel No. LV-H368KLB0 Model No. LV-H368KLA0Model No. LV-H488LLB0 Model No. LV-H488LLA0Model No. LV-C368KLA0 Model No. LV-H608LLAB0Model No. LV-C488LLA0 Model No. LV-C368KLB0Model No. LV-C608LLAB0 Model No. LV-C488LLB0Model No. LV-C488LLA1 Model No. LV-C368KLA1Model No. LV-C608LLA1 Model No. LV-B182464CL, LV-B2860CL Refrigerant Cycle DiagramsModel No. LV-B182464HBL, LV-B2860HL Model No. LV-C3681HL, LV-D4881HL, LV-D6081HL Model No. LV-C3681CL, LV-D4881CL, LV-D6081CLModel No. LV-H368KLAB0 Model No. LV-C368KLAB0Model No. LV-H488LLAB0 Model No. LV-C488LLAB0Model No. LV-C608LLAB0 Model No. LV-C48608LLA1 Determine cooling load requirements at design conditions Selection ProcedureSelect unit based on required cooling capacity Determine if system selected satisfies cooling requirementsModel No. LV-B1864CL Performance DataModel No. LV-B1864HBL Model No. LV-B2860CHL Model No. LV-B2464HBL20.2 Model No. LV-D6081HL Model No. LV-CH488LLAB0, LV-C488LLA1 Model No. LV-CH368KLAB0Heating Capacity Model No. LV-H488LLAB0 Correction Factor Capacity% Coefficient of Capacity ChangeTotal Pipe Lengthm Model Additional RefrigerantCapacity% Model No. LV-CH368KLAB0, LV-CH48608LLAB0Total Pipe Lengthm Model No. LV-C368KLA1, LV-C48608LLA1Limit Operation Limit18kBtu/h Models Installation on ceiling Cooling Heating Air Velocity and Temperature DistributionsReference DataCooling Heating LV-B1864CH/BL Sound LevelsLV-C3681CHL LV-C368KLA1 Indoor Unit InstallationOutdoor Unit Before Installing, prepare Installation Plates Installation on the ceilingVB Chassis Models Lower slot Side of view Front of viewBefore working, refer to Flaring Work on Than 260 265 Installation on the WallInner slot After Installing, reassemble detached parts Installation on the floorVC/VD Chassis Models Safety considerationsInitial check Location & MountingRefrigerant piping Condensate drainInstallation Electrical wiringFilter removal for cleaning Air flow direction adjustmentVK/VL Chassis Models Installation of UnitOpen side cover Preparing work for InstallationDim Model 48k, 60k 1655 320 Mounting the anchor Nut & BoltCeiling MountingInstallation Information For Declination Indoor unit installationSelect the following location Keep a maintenance spaceCutting the pipes and the cable Flaring WorkRemoving burrs Putting nut onCheck Connecting of Piping IndoorWrap the insulation material around con- nection portion Foamed polyethylene or equivalent is recom- mended Connection of the pipes-Outdoor To check the drainage Checking the DrainageDrain piping Seal small openings around pipings with a gum type sealer Clamping of cables Connecting cables to the Indoor UnitElectric Wire Size Connecting the cable to Outdoor UnitVK/VL Chassis Models Connecting cables to the Indoor Unit Indoor Electrical Wiring VK/VL ChassisConnecting the cable to the Outdoor Unit For VC/VD Chassis Model Function of Remote ControllerCooling Only Model18k, 24k, 28k Signal transmitterHeat Pump Model 18k, 24k, 28k 14 2nd F Button For VK/VL Chassis ModelsNo A20429N

5CSV2-03A specifications

LG Electronics has established itself as a leader in consumer electronics, and the 5CSV2-03A model exemplifies the brand's commitment to innovation and performance. This model showcases a blend of advanced technologies and user-friendly features, making it a standout choice for modern households.

One of the key attributes of the LG 5CSV2-03A is its energy efficiency. It operates with a high Energy Efficiency Ratio (EER), which ensures that users can enjoy powerful performance while minimizing energy consumption. This not only helps in reducing electricity bills but also aligns with global efforts toward sustainability.

The 5CSV2-03A is equipped with cutting-edge inverter technology, allowing it to adjust the compressor's speed based on cooling demand. This leads to more consistent temperature control, quieter operation, and reduced energy use. Users will appreciate the swift cooling capabilities, making uncomfortable heat a thing of the past.

Another significant feature is the air purification technology. The model integrates advanced filters that capture airborne particles, allergens, and even odors, contributing to a healthier living environment. The built-in air quality monitoring system provides real-time feedback, helping users maintain optimal indoor air quality.

Convenience is taken to the next level with smart connectivity options. With Wi-Fi capabilities, users can control the 5CSV2-03A via a smartphone app, offering the flexibility to adjust settings from anywhere within the home. This feature also enables scheduling operations, allowing users to pre-cool their spaces before arriving home.

The design of the 5CSV2-03A reflects LG's dedication to aesthetics and functionality. Its sleek and modern look fits seamlessly into various interior styles, ensuring that it doesn’t detract from the overall decor. Additionally, the model boasts low noise levels, ensuring peace and comfort, especially in bedrooms or quiet spaces.

Lastly, the durability and reliability of LG products are well-known. The 5CSV2-03A is constructed with robust materials and components, ensuring longevity and performance even under demanding conditions.

In summary, the LG Electronics 5CSV2-03A combines energy efficiency, innovative technology, air purification, smart features, and an attractive design, making it an excellent choice for consumers seeking effective and stylish climate control solutions for their homes.