LG Electronics 5CSV2-03A manual Connecting the cable to Outdoor Unit, Electric Wire Size

Page 83

15. Installation

3)Connecting the cable to Outdoor Unit

1.Remove the control cover from the unit by loosening a screw.

Connect the wires to the terminals on the control board individually as specified.

2.Secure the cable onto the control board with the hold- er (clamper).

3.Refix the cover control to the original position with the screw.

4.Use a recongnized circuit breaker 20A(18k, 24k) between the power source and the unit. A disconnec- tion device to adequately disconnect all supply lines must be fitted.

Outdoor unit

Terminal block

Over 5mm

Holder for

 

power supply

cord

Power supply

 

cord

 

Connecting

 

cable

Cover control

Holder for

 

connecting

 

cable

VC/VD Chassis Models

ELECTRIC WIRE SIZE

 

OUTDOOR

INDOOR FUSE

CIRCUIT

ELECTRIC WIRE SIZE (SQMM)

MODEL

FUSE CON-

ON THE

IN PIPE

CONTROL

BREAKER

 

TROL

GROUND 60°C

75°C

 

 

 

 

 

 

 

 

 

36k

10A / 250V

0.5A / 250V

30A / 3P.

-

6

48k/60k

10A / 250V

0.5A / 250V

50A / 3P.

-

6

CAUTION

After the confirmation of the above conditions, prepare the wiring as follows:

1)Never fail to have an individual power specially for the air conditioner. Guidence for wiring is in the circuit diagram which is pasted on the inside of control box cover.

2)Provide a circuit breaker switch between power source and the unit.

3)The screw which fasten the wiring in the casing of electrical fittings are liable to become loose due to vibrations, to which the unit is subjected during the course of transportation. Check them and make sure that they all are tightly fastened. (If they are loose, it could burn-out the wires.)

4)Confirm specification of power source.

5)Confirm electrical capacity is sufficient.

6)Be sure that the starting voltage is maintained at more than 90 percent of the rated voltage marked on the name plate.

7)Confirm the cable thickness should be proper as specified in the power sources specification. (Particularly note the relation between cable length and thickness.)

8)Never fail to equip a leakage breaker where it is wet or moist.

9)The following troubles would be caused by voltage drop-down.

Vibration of a magnetic switch, damage on the contact point there of, fuse breaking, disturbance to the normal function of a overload protection device.

Proper starting power is not given to the compressor.

10)The means for disconnection from a power supply shall be incorporated in the fixed wiring and have an air gap contact separation of at least 3mm in each active(phase) conductors.

82Ceiling & Floor, Ceiling Suspended (50Hz, R22)

Image 83
Contents Ceiling & Floor50Hz, R22 Ceiling Suspended50Hz, R22 LG Electronics Inc General DescriptionCeiling & Floor, Ceiling Suspended 50Hz, R22 Table of Contents Cooling Only Models ListIdentification Rule Model Number NomenclatureFeatures & Benefits List of Functions Air Discharge outlet Airflow Direction control left & right LV-C368KLA01 Features Ceiling SuspendedLV-C488LLA01 LV-H488LLA0 LV-C488LLB0 LV-H608LLA0 LV-C608LLB0 LV-B1864CL LV-B1864HBL LV-B2464CL LV-B2464HBL SpecificationsLV-B2860CL LV-B2860HL LV-C3681CL LV-C3681HL LV-D4881CL LV-D4881HL LV-D6081CL LV-D6081HL LV-H368KLAB0 LV-H488LLAB0 LV-H608LLAB0 LV-C368KLAB0 LV-C488LLAB0 LV-C608LLAB0 LV-C368KLA1 LV-C488LLA1 LV-C608LLA1 Outdoor Unit Dimensional DrawingsModel No. LV-B1864CH/BL, LV-B2464CH/BL, LV-B2860CHL Indoor UnitModel No. LV-C3681CHL, LV-D486081CHL Dimensional Drawings ABC Model No. LV-CH368KLAB0, LV-C368KLA1 LV-CH48608LLAB0, LV-C48608LLA1 Model No. LV-CH48608LLAB0, LV-C48608LLA1Model No. LV-B1864HBL, LV-B2464HBL Wiring DiagramsModel No. LV-B1864CL, LV-B2464CL Model No. LV-B2860HL Model No. LV-B2860CLIndoor Unit Outdoor Unit Model No. LV-C3681HLModel No. LV-C3681CL Model No. LV-D4881CL Model No. LV-D4881HLModel No. LV-D6081CL Model No. LV-D6081HLModel No. LV-H368KLB0 Model No. LV-H368KLA0Model No. LV-H488LLB0 Model No. LV-H488LLA0Model No. LV-C368KLA0 Model No. LV-H608LLAB0Model No. LV-C488LLA0 Model No. LV-C368KLB0Model No. LV-C608LLAB0 Model No. LV-C488LLB0Model No. LV-C488LLA1 Model No. LV-C368KLA1Model No. LV-C608LLA1 Model No. LV-B182464HBL, LV-B2860HL Refrigerant Cycle DiagramsModel No. LV-B182464CL, LV-B2860CL Model No. LV-C3681HL, LV-D4881HL, LV-D6081HL Model No. LV-C3681CL, LV-D4881CL, LV-D6081CLModel No. LV-H368KLAB0 Model No. LV-C368KLAB0Model No. LV-H488LLAB0 Model No. LV-C488LLAB0Model No. LV-C608LLAB0 Model No. LV-C48608LLA1 Determine if system selected satisfies cooling requirements Selection ProcedureDetermine cooling load requirements at design conditions Select unit based on required cooling capacityModel No. LV-B1864HBL Performance DataModel No. LV-B1864CL Model No. LV-B2860CHL Model No. LV-B2464HBL20.2 Model No. LV-D6081HL Model No. LV-CH488LLAB0, LV-C488LLA1 Model No. LV-CH368KLAB0Heating Capacity Model No. LV-H488LLAB0 Correction Factor Model Additional Refrigerant Coefficient of Capacity ChangeCapacity% Total Pipe LengthmCapacity% Model No. LV-CH368KLAB0, LV-CH48608LLAB0Total Pipe Lengthm Model No. LV-C368KLA1, LV-C48608LLA1Limit Operation LimitCooling Heating Air Velocity and Temperature DistributionsReference Data18kBtu/h Models Installation on ceiling Cooling Heating LV-C3681CHL Sound LevelsLV-B1864CH/BL LV-C368KLA1 Outdoor Unit InstallationIndoor Unit VB Chassis Models Installation on the ceilingBefore Installing, prepare Installation Plates Lower slot Side of view Front of viewBefore working, refer to Flaring Work on Than 260 265 Installation on the WallInner slot After Installing, reassemble detached parts Installation on the floorLocation & Mounting Safety considerationsVC/VD Chassis Models Initial checkRefrigerant piping Condensate drainInstallation Electrical wiringFilter removal for cleaning Air flow direction adjustmentVK/VL Chassis Models Installation of UnitOpen side cover Preparing work for InstallationDim Model 48k, 60k 1655 320 Mounting the anchor Nut & BoltCeiling MountingInstallation Information For Declination Indoor unit installationSelect the following location Keep a maintenance spacePutting nut on Flaring WorkCutting the pipes and the cable Removing burrsWrap the insulation material around con- nection portion Connecting of Piping IndoorCheck Foamed polyethylene or equivalent is recom- mended Connection of the pipes-Outdoor Drain piping Checking the DrainageTo check the drainage Seal small openings around pipings with a gum type sealer Clamping of cables Connecting cables to the Indoor UnitElectric Wire Size Connecting the cable to Outdoor UnitVK/VL Chassis Models Connecting cables to the Indoor Unit Indoor Electrical Wiring VK/VL ChassisConnecting the cable to the Outdoor Unit For VC/VD Chassis Model Function of Remote ControllerCooling Only Model18k, 24k, 28k Signal transmitterHeat Pump Model 18k, 24k, 28k 14 2nd F Button For VK/VL Chassis ModelsNo A20429N

5CSV2-03A specifications

LG Electronics has established itself as a leader in consumer electronics, and the 5CSV2-03A model exemplifies the brand's commitment to innovation and performance. This model showcases a blend of advanced technologies and user-friendly features, making it a standout choice for modern households.

One of the key attributes of the LG 5CSV2-03A is its energy efficiency. It operates with a high Energy Efficiency Ratio (EER), which ensures that users can enjoy powerful performance while minimizing energy consumption. This not only helps in reducing electricity bills but also aligns with global efforts toward sustainability.

The 5CSV2-03A is equipped with cutting-edge inverter technology, allowing it to adjust the compressor's speed based on cooling demand. This leads to more consistent temperature control, quieter operation, and reduced energy use. Users will appreciate the swift cooling capabilities, making uncomfortable heat a thing of the past.

Another significant feature is the air purification technology. The model integrates advanced filters that capture airborne particles, allergens, and even odors, contributing to a healthier living environment. The built-in air quality monitoring system provides real-time feedback, helping users maintain optimal indoor air quality.

Convenience is taken to the next level with smart connectivity options. With Wi-Fi capabilities, users can control the 5CSV2-03A via a smartphone app, offering the flexibility to adjust settings from anywhere within the home. This feature also enables scheduling operations, allowing users to pre-cool their spaces before arriving home.

The design of the 5CSV2-03A reflects LG's dedication to aesthetics and functionality. Its sleek and modern look fits seamlessly into various interior styles, ensuring that it doesn’t detract from the overall decor. Additionally, the model boasts low noise levels, ensuring peace and comfort, especially in bedrooms or quiet spaces.

Lastly, the durability and reliability of LG products are well-known. The 5CSV2-03A is constructed with robust materials and components, ensuring longevity and performance even under demanding conditions.

In summary, the LG Electronics 5CSV2-03A combines energy efficiency, innovative technology, air purification, smart features, and an attractive design, making it an excellent choice for consumers seeking effective and stylish climate control solutions for their homes.