OPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS
Before Use
1.This cordless hand vacuum is powered by rechargeable nickel- cadmium batteries. Before using the vacuum, charge the vacuum cleaner for a minimum of 20 hours.
Note: Ensure that the On/Off switch is in the “Off” position before charging.
Note: Peak performance may only be realized after the unit has been charged and discharged two (2) or three (3) times. IMPORTANT: To maintain peak performance of your cordless hand vacuum, it is recommended that the unit be fully discharged, then completely re- charged at least once a month.
Charging Your Vacuum Cleaner
1.Place the vacuum cleaner and charging adapter near an electrical power outlet (120 V., 60 Hz.) and plug in the charging adapter‘s jack into the vacuum.
2.Plug the charger into wall outlet.
3.The charging indicator light will shine red to indicate that the charging jack is properly inserted into the charging receptacle at the rear of the unit and that the unit is being charged. (Fig. 1)
Note: Ensure that the On/Off switch is in the "Off" position before charging.
Charging
Jack
To Maximize the Life of your Ni-Cd Batteries
1.Charge for a minimum of 20 hours before initial use. Failure to do so will reduce the product’s battery life significantly.
2.Do not store the unit with the charging adaptor attached and plugged in.
3.Only recharge when the batteries are fully discharged (or as close to fully discharged as possible).
4.Do not store in areas of high temperature or humidity.
5.Fully discharge, then completely
6.After three (3) months of storage, the product should be fully discharged and then recharged to maximize battery power.
7.Use only the charger supplied with the product. If other chargers are used, the batteries can fail causing damage to the battery, product or personal property.
8.
replaced. To purchase replacement batteries visit www.sharkvac.com.
Note:
1. | The on/off switch must be in the |
| “OFF” position in order to charge the |
| unit. If the charging indicator does not |
| light, depress the on/off switch once. |
2. | If the product has never been used or |
Battery Pack Replacement & Disposal
WARNING: NEVER use ordinary batteries for replacement, as these may leak and damage your vacuum cleaner. Use only battery pack XB7729 provided by
This vacuum cleaner contains a nickel- cadmium
If uncertain as to how to remove the battery pack, we suggest you take your wet/dry hand vacuum to a reputable small appliance service technician to have this service preformed.
The battery pack of your SV7729 is replaceable, however care should be taken when doing so. Follow these steps when replacement is required:
1. | Open the battery pack compartment |
| by removing the single Phillips head |
| screw located in the recess at the |
| rear of the unit. NEVER open the |
| battery compartment except to |
| change the battery pack when |
| required. |
2. | Remove battery compartment cover. |
| Set aside battery compartment cover |
| with the screw. |
3. | Carefully detach the two (2) electrical |
5.Insert the new battery pack and re- connect the terminals by pushing lead wires onto battery tabs.
6.Tuck the wiring inside the battery compartment so that the wiring does not interfere with the battery compartment cover when it is replaced.
7.
8.Replace the battery compartment cover screw.
CAUTION: NEVER use the unit without the battery compartment cover in place. Note: Any other servicing should be performed by an authorized service representative.
CAUTION
•Use only with the battery pack supplied with the unit.
•Do not attempt to remove the battery pack from the unit to charge it.
•Never attempt to throw the battery pack or unit into a fire or incinerate it.
•Do not attempt to remove or damage the battery casing.
•Battery must be recycled or disposed of properly at the end of it's service life.
Fig. 1
Charging
Receptacle
has been stored for an extended |
period of time without use – it will take |
several complete charge and |
discharge cycles to realize the full |
operational time of your product. |
connectors from the battery pack by |
pulling straight out from the battery |
pack. |
4. Lift out the battery pack and set |
aside. |
4.The normal full charging time for this vacuum is 20 hours. The vacuum cleaner will run for maximum operational time only if it has been fully charged. To fully charge the unit, run the vacuum cleaner until it stops, then fully recharge the battery.
34