Graco 239877 Series D Dimension Drawings, Mounting Hole Layout, Hole Mounting Pattern

Page 14

Dimension Drawings

Dimension Drawings

 

 

 

 

 

grounding screw

 

grounding screw

 

grounding screw

 

3/8 npt(f)

 

 

 

 

 

3/8 npt(f)

 

 

 

air inlet

 

 

3/8 npt(f)

 

 

1/4 npt(f)

air inlet

1/4 npt(f)

air inlet

1/4 npt(f)

 

 

 

 

fluid outlet

 

fluid outlet

 

fluid outlet

17.5 in.

26.7 in.

33.6 in.

(445 mm)

(678 mm)

 

 

(853 mm)

Overall length:

Overall length:

31 in. (788 mm)

38.4 in. (975 mm)

Overall length: 45.4 in. (1153 mm)

Mounting Hole Layout

2-Hole Mounting

4-Hole Mounting

Pattern

Pattern

161023 gasket

two or four 0.265 in. (7 mm) dia. holes on 5 in. (127 mm) bolt circle

3 in. (76.2 mm) dia.

14

308883S

Image 14
Contents Fire-Ball300 Pump Equipment Misuse Hazard Installation GroundingAir and Fluid Line Accessories MountingStart Up Pressure Relief ProcedureOperation Displacement Pump Service RepairRepair Air Motor and Throat Service Repair 308883S Air Motor and Throat Seals Cutaway ViewTroubleshooting Problem Cause SolutionParts Part Description Part Description QtyHole Mounting Pattern Dimension DrawingsMounting Hole Layout Technical Data Fire-Ball300 Pumps MetricGraco Standard Warranty Graco Information