Graco 308550ZAC important safety instructions Toxic Fluid Hazard

Page 4

WARNING

TOXIC FLUID HAZARD

Hazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin, inhaled, or swallowed.

DKnow the specific hazards of the fluid you are using.

DStore hazardous fluid in an approved container. Dispose of hazardous fluid according to all local, state and national guidelines.

DAlways wear protective eyewear, gloves, clothing and respirator as recommended by the fluid and solvent manufacturer.

DPipe and dispose of the exhaust air safely, away from people, animals, and food handling areas. If the diaphragm fails, the fluid is exhausted along with the air. See Air Exhaust Ventilation on page 11.

FIRE AND EXPLOSION HAZARD

Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury.

DGround the equipment. Refer to Grounding on page 6.

DNever use a polypropylene or PVDF pump with non-conductive flammable fluids as specified by your local fire protection code. Refer to Grounding on page 6 for additional information. Consult your fluid supplier to determine the conductivity or resistivity of your fluid.

DIf there is any static sparking or you feel an electric shock while using this equipment, stop pumping immediately. Do not use the equipment until you identify and correct the problem.

DProvide fresh air ventilation to avoid the buildup of flammable fumes from solvents or the fluid being sprayed, dispensed, or transferred.

DPipe and dispose of the exhaust air safely, away from all sources of ignition. If the diaphragm fails, the fluid is exhausted along with the air. See Air Exhaust Ventilation on page 11.

DKeep the work area free of debris, including solvent, rags, and gasoline.

DElectrically disconnect all equipment in the work area.

DExtinguish all open flames or pilot lights in the work area.

DDo not smoke in the work area.

DDo not turn on or off any light switch in the work area while operating or if fumes are present.

DDo not operate a gasoline engine in the work area.

4 308550

Image 4
Contents Instructions Parts List Important Safety InstructionsTable of Contents ModelsSymbols Equipment Misuse HazardToxic Fluid Hazard Installation General InformationTighten Screws Before First Use Toxic Fluid HazardGrounding Ground all of this equipmentTypical FLOOR-MOUNT Installation Air LineInstallation of Remote Pilot Air Lines MountingsFluid Suction Line Fluid Outlet LineFlange Connections Bolt Tightening SequenceChanging the Orientation of the Fluid Inlet and Outlet Ports Fluid Pressure Relief ValveFire and Explosion Hazard Air Exhaust VentilationVenting Exhaust AIR Pressure Relief Procedure Starting and Adjusting the PumpOperation Flush the Pump Before First UseMaintenance Troubleshooting Problem Cause SolutionTroubleshooting Service Repairing the Air ValveDisassembly Tools RequiredReassembly Ball Check Valve Repair Relieve the pressure. Disconnect all hosesDiaphragm Repair Reassembly Standard Diaphragms Reassembly Overmolded Diaphragms 105 19 402 24 104 403 Bearing and Air Gasket Removal Detail of Air Valve Bearings 308550 Pump Matrix Husky 2150 Polypropylene and Pvdf Pumps, Series aRepair Kit Matrix For Husky 2150 Polypropylene and Pvdf Pumps, Series aAir Motor Parts List Matrix Column PartsFluid Section Parts List Matrix Column MufflerBall Parts List Matrix Column Seat Parts List Matrix ColumnDiaphragm Parts List Matrix Column 114 Torque Sequence Front View DimensionsSide View Pump Mounting Hole Pattern Technical Data 14-0.8 MPa, 1.4-8 barPerformance Chart Feet metersPsi MPa, bar Fluid Flow GPM lpmGraco Warranties Graco Information