pump saFetY

Danger

„ never operate the equipment in an explosive atmosphere or near combustible materials.An explosion or fi re could result causing severe bodily harm or even death.

Warning

„ Accidental starting can cause severe injury or death. alWaYs place the ON/OFF switch in the OFF position.

„Do not place hands or fingers inside

pump when pump is running.

„never disconnect any emergency or

safety devices. These devices are intended for operator safety. Disconnection of these devices can cause severe injury, bodily harm or even death. Disconnection of any of these devices will void all warranties.

„Risk of Electric Shock - This pump has not been investigated for use in swimming pool or marine areas.

Caution

„Do not restrict the fl ow of the discharge hose as it may cause the pump to overheat.

„Be careful of discharge hose whipping under pressure.

„alWaYs check pump oil level only when pump is cool. Expansion due to heat may cause hot oil to spray from the oil plug when the oil plug is removed. The possibility of severe scalding may exist.

NOTICE

„alWaYs place the pump in an upright position on a platform before using.The platform will prevent the pump from burrowing itself on soft sand or mud.

„never operate pump on its side.

„Do not allow the pump to freeze in water.

„never leave an open pump chamber unattended.

„alWaYs keep the machine in proper running condition.

„Do not attempt to thaw out a frozen pump by using a torch or other source of fl ame. Application of heat in this manner may heat the oil in the seal cavity above the critical point, causing pump damage.

„Do not pump water with a temperature greater than 140°F (60°C).

„Do not pump liquids containing acid or alkali.

„alWaYs check strainer before pumping. Make sure strainer is not clogged. Remove any large objects, dirt or debris from the strainer to prevent clogging.

„alWaYs use a large basket strainer when pumping water that contains large debris.

„alWaYs fl ush pump (clean) after use when pumping water concentrated with heavy debris. It is very important to always fl ush the pump before turning it off to prevent clogging.

„Fix damage to machine and replace any broken parts immediately.

„alWaYs store equipment properly when it is not being used. Equipment should be stored in a clean, dry location out of the reach of children and unauthorized personnel.

„never lubricate components or attempt service on a running machine.

„never run pump dry.

„alWaYs allow the machine a proper amount of time to cool before servicing.

„Keep machine in proper running condition.

eleCtriCal saFetY

Danger

„ The electrical voltage required to operate pump can cause severe injury or even death through physical contact with live circuits. alWaYs disconnect electrical power from pump before performing maintenance on pump.

Warning

„To reduce the risk of electric shock, connect only to a circuit protected by a Ground-Fault Circuit-Interrupter (GFCI).

page 6 — st4/ST6 series submersible pumps • operation AND PARTS manual — rev. #1 (11/12/13)

Image 6
Contents Model st41230/st41460 Model st61230/st61460 Table of Contents ST41230/ST41460 ST61230/ST61460 Submersible PumpsChoose from three easy options SaFetY sYmbols Safety InformationSaFetY messages SymbolGeneral saFetY Pump saFetY EleCtriCal saFetY„ never disconnect any emergency or Control box safety Power Cord/Cable safetyGrounding safety LiFting saFetYSpecifications SpecificationsDimensions Pump DimensionsGeneral information Components Submersible Pump ComponentsDesign Features Float switchesMechanical Float Switch How It WorksFloat Switches Mounting The Float SwitchesUsed With Control Box SpecificationsControl Boxes HeaterPhase Power Installation Input Control box installationControl Box Installation Power Cord RequirementsConnecting SW-1WOPA Float Switches to Control Box Dual Float switch ConnectionsFloat Terminal Wire 230/460 VAC Input Power Connections Control Box power connectionsPhase Power Installation Output To Pump 230/460 VAC Output Power ConnectionsControl box wiring layout 1L1 5L3Pump Placement OperationReset Button Control Box Operation Auto ModeShut-Down Maintenance LubricationMechanival Seal Replacement Impeller RemovalElectrical Insulation Testing Water Tank StorageLong Term Storage Page Troubleshooting Pump TroubleshootingControl box wiring diagram CB1269/CB1274 Three Phase Wiring ConnectionsControl box wiring diagram CB1456/CB1463 QtY. Column No. ColumnPart no. Column Remarks ColumnSuggested Spare Parts Qty DescriptionST41230/ST41460 Assy Part Name QTY ST41230/ST41460 Assy Part Name QTY Remarks ST61230/ST61460 Assy SCREW, HEX. M6 ST61230/ST61460 Assy WASHER, Lock M8 Terms and Conditions of Sale Parts FreigHt poliCYPage HERE’S HOW to GET Help

ST61230, ST61460, ST41230, ST41460 specifications

The Multiquip ST41460, ST41230, ST61460, and ST61230 are a series of portable generators designed to meet the power needs of various applications, from construction sites to outdoor events. These generators combine robust performance with user-friendly features, enabling operators to rely on them for consistent power delivery.

Starting with the ST41460, this generator provides a maximum output of 4,600 watts, making it an ideal choice for users requiring significant power. It is equipped with a powerful Honda engine known for its fuel efficiency and durability. The dual fuel capability allows the ST41460 to run on either gasoline or propane, providing flexibility in fuel choice depending on availability or preference. Additionally, the unit features a compact design, making it easy to transport and store.

The ST41230 is optimized for those who need a lighter and more portable option without sacrificing performance. With a maximum output of 3,000 watts, it is perfect for powering tools, lights, and small appliances. This generator also offers a quiet operation, making it suitable for residential areas or events where noise reduction is a priority. The ST41230 further includes a digital panel that displays fuel level and run time, enhancing usability and monitoring.

Moving to the ST61460, this model takes power output up a notch with 6,000 watts peak capacity. Its heavy-duty construction ensures reliability on job sites, while the full-length skid base offers added stability and protection. This unit is also equipped with advanced inverter technology, providing clean and stable power perfect for sensitive electronics.

Lastly, the ST61230 features a balance of power and portability, with a maximum output of 3,000 watts that caters well to users in need of moderate power for tools and recreational use. The incorporation of safety features such as low-oil shutdown and circuit breaker ensures that the generator operates safely and reduces the risk of damage to connected devices.

Each of these Multiquip generators boasts user-friendly features, including easy-start systems, multiple outlet options, and rugged wheels for enhanced mobility. With their reliable performance, advanced technologies, and robust construction, the ST41460, ST41230, ST61460, and ST61230 models are ideal solutions for anyone seeking dependable power in various settings. Whether for construction, home use, or recreational activities, these generators provide reliable support for all power needs.