SBN71-120 thru SBN85-390, SBD30-150/199 TANK TYPE COMMERCIAL

GAS WATER HEATER SERVICE HANDBOOK

WATER HEATER CONTROL BOARD TROUBLESHOOTING AND DIAGNOSTIC LED INTERPRETATION

Conditions:

Power On

Red, heater control “Call for Heat” LED – on

Red, ignition control board diagnostic LED – Flashing

Note LED Flash Code before resetting heater.

LED Status

Indication

1

Flash

System is in lock out.

 

 

 

2

Flashes

Draft proving (pressure) switch failed to open within 5 seconds at the end of the last

 

 

cycle.

3

Flashes

Draft proving (pressure) switch failed to close ( -2.1 inches of water column pressure)

 

 

within 5 seconds after the inducer was started. The low gas pressure switch )closes

 

 

at 5.2" ± .04" w. c.) may have remained open (Nat Gas only.)

4 Flashes

Open on high temperature limit switch (ECO).

 

 

5 Flashes

Not Used

 

 

6 Flashes

115-volt supply power connection is indicating reversed polarity.

 

 

7 Flashes

Flame sensor reads a low flame signal for more than 4.25 sec.

 

 

 

8

Flashes

No ignition sensed.

 

 

Continuous Flash

Continuous flame sensed for more than 5 seconds without gas valve being energized.

 

 

Continuous ON

Internal control board failure.

*Control system self adjusts to use a minimum voltage for ignition. Lower voltage results in lower IGNITOR temperature which results in longer IGNITOR life. IGNITOR voltage may vary from Nominal 80 VAC.

State Water Heaters

34

Technical Training Department

Ashland City, Tennessee © 2007

 

 

Image 35 Contents
SandBlaster Table of Contents No Igniter Operation Commercial Tank Type GAS Model Number Break Down GAS Water Heater Service Handbook QualificationsTools Required TOP and Front Views of Minimum Clearances to Combustibles Model Number Right Side Left Side Back D Ceiling SBN71-120 thru 85-390, SBD30-150/199 Tank Type Commercial Insufficient Makeup AIR Negative AIR Pressure Square Inch PER AIR for Combustion Flammable Items GAS Water Heater Service Handbook Contaminated AIRInlet View TOP View GAS Water Heater Service Handbook GAS ValveOutlet View Venting Multiple Category I GAS Water Heaters GAS Water Heater Service Handbook VentingMultiple Gas Fired Tank-Type Heaters Model SBN80-180 SBN100-199 SBN100-200 SBD30-199 Model SBN100-250 Model SBN Model SBN 85-366NE, SBN 85-390NE Sequence Vent Size Area Square Inches 113 154 201 254 GAS Water Heater Service Handbook Rules for Good Venting GAS Water Heater Service Handbook Rules for Good Venting Horizontal Elements Limited to 75% of Total Vertical Height Models SBN SBDSBN71-120 thru SBN85-390, SBD30-150/199 Tank Type Commercial SBN71-120 thru SBN85-390, SBD30-150/199 Tank Type Commercial SBN71-120 thru SBN85-390, SBD30-150/199 Tank Type Commercial HSI GAS Water Heater Service Handbook Wiring Diagram SBN71-120 thru SBN85-390, SBD30-150/199 Tank Type Commercial SBN71-120 thru SBN85-390, SBD30-150/199 Tank Type Commercial SBN71-120 thru SBN85-390, SBD30-150/199 Tank Type Commercial GAS Water Heater Service Handbook PRE-SERVICE Check List Then TestConditions GAS Water Heater Service Handbook Test 2 Polarity Check Ohms Ohms Resistance Table Water Heater Control Thermostat 120 VAC Check of Blower Prover/Low Gas Pressure Circuit No Ignitor Operation Test Ignitor Heats No Main Burner No Main BurnerMeter reads 0 or Main Burner Ignition for Less than 5 Seconds Water Temperature Circuit Check Continuity SBN71-120 thru SBN85-390, SBD30-150/199 Tank Type Commercial Parts SBN71-120 thru 85-390 series GAS Water Heater Service Handbook GAS Water Heater Service Handbook GAS Water Heater Service Handbook GAS Water Heater Service Handbook GAS Water Heater Service Handbook Parts SBD30-150/199NE GAS Water Heater Service Handbook Commercial