State Industries SBN71 120, SBD30 150, SBN85 390 (A), SBD30 199, SERIES 108 manual Ohms

Page 37

SBN71-120 thru SBN85-390, SBD30-150/199 TANK TYPE COMMERCIAL

GAS WATER HEATER SERVICE HANDBOOK

TEST 3 - CONTINUITY CHECK OF HIGH LIMIT (ECO)

Conditions:

Power On – No Hot Water

Red, heater control “Call for Heat” LED – on

Red ignition control board diagnostic LED – 4 Flashing

Note LED Flash Code before resetting water heater control.

See Description of diagnostic LED Flashes.

Turn Power “Off”

0.0

Ohms

TEST 3

Continuity check of ECO (energy cut-off, high limit)

 

Black to Black wires of upper probe. Power is off.

 

 

 

If…

then

continuity is indicated (ZERO “0.0” Resistance)

opens at 203° F; closes at 193° F. If water is

 

below 193° F, continuity is correct.

continuity is not present (meter reads “0.L”)

replace ECO sensor, if water temperature is

 

below 193° F.

water is less than 120° F

•reset status LED should be on.

 

•replace heater control if control will not manually

 

reset.

State Water Heaters

36

Technical Training Department

Ashland City, Tennessee © 2007

 

 

Image 37 Contents
SandBlaster Table of Contents No Igniter Operation Tools Required GAS Water Heater Service Handbook QualificationsCommercial Tank Type GAS Model Number Break Down TOP and Front Views of Minimum Clearances to Combustibles Model Number Right Side Left Side Back D Ceiling SBN71-120 thru 85-390, SBD30-150/199 Tank Type Commercial Insufficient Makeup AIR Negative AIR Pressure Square Inch PER AIR for Combustion Flammable Items GAS Water Heater Service Handbook Contaminated AIRInlet View TOP View GAS Water Heater Service Handbook GAS ValveOutlet View Venting Multiple Category I GAS Water Heaters GAS Water Heater Service Handbook VentingMultiple Gas Fired Tank-Type Heaters Model SBN80-180 SBN100-199 SBN100-200 SBD30-199 Model SBN100-250 Model SBN Model SBN 85-366NE, SBN 85-390NE Sequence Vent Size Area Square Inches 113 154 201 254 GAS Water Heater Service Handbook Rules for Good Venting GAS Water Heater Service Handbook Rules for Good Venting Horizontal Elements Limited to 75% of Total Vertical Height Models SBN SBDSBN71-120 thru SBN85-390, SBD30-150/199 Tank Type Commercial SBN71-120 thru SBN85-390, SBD30-150/199 Tank Type Commercial SBN71-120 thru SBN85-390, SBD30-150/199 Tank Type Commercial HSI GAS Water Heater Service Handbook Wiring Diagram SBN71-120 thru SBN85-390, SBD30-150/199 Tank Type Commercial SBN71-120 thru SBN85-390, SBD30-150/199 Tank Type Commercial SBN71-120 thru SBN85-390, SBD30-150/199 Tank Type Commercial GAS Water Heater Service Handbook PRE-SERVICE Check List Then TestConditions GAS Water Heater Service Handbook Test 2 Polarity Check Ohms Ohms Resistance Table Water Heater Control Thermostat 120 VAC Check of Blower Prover/Low Gas Pressure Circuit No Ignitor Operation Test Ignitor Heats No Main Burner No Main BurnerMeter reads 0 or Main Burner Ignition for Less than 5 Seconds Water Temperature Circuit Check Continuity SBN71-120 thru SBN85-390, SBD30-150/199 Tank Type Commercial Parts SBN71-120 thru 85-390 series GAS Water Heater Service Handbook GAS Water Heater Service Handbook GAS Water Heater Service Handbook GAS Water Heater Service Handbook GAS Water Heater Service Handbook Parts SBD30-150/199NE GAS Water Heater Service Handbook Commercial