Multiquip ST2038P, ST204B, ST2047, ST204OT ST2037, 47, 47B, 38P, 40T SUB. Pump -TROUBLESHOOTING

Page 20

ST2037, 47, 47B, 38P, 40T SUB. PUMP TROUBLESHOOTING

Practically all breakdowns can be prevented by proper handling and maintenance inspections, but in the event of a breakdown, use Table 8 (Pump Troubleshooting) as a basic guideline for troubleshooting the pump. If the problem cannot be remedied, contact Multiquip's service department.

TABLE 8. PUMP TROUBLESHOOTING

SYMPTOM

POSSIBLE PROBLEM

SOLUTION

 

 

 

 

 

Check that proper voltage (115 VAC, 60 Hz, single-phase ) is being

 

Incorrect voltage/amps?

supplied to the pump. Also check that there is an adequate amount

 

of current (amps) to run the pump. Check power source circuit

 

 

 

 

breaker.

 

 

 

 

Check electrical connections?

If using float switches check wiring, inspect power cord.

 

 

 

 

Blown power fuse?

Replace fuse, check cause of blown fuse.

Pump Fails To Start

 

 

Impeller locked?

Disconnect power cord and check for clogging. Unclog pump. Check

 

 

overload protection device.

 

 

 

 

 

 

 

Use multimeter to check motor insulation. Insulation resistance must

 

Wet motor windings?

be approximately 15 megaohms. If resistance is low, disassemble

 

 

pump motor and bake windings to dry them.

 

 

 

 

Defective motor and pump

Check for excessive bearing wear, if worn replace bearings. Replace

 

bearings?

motor if defective.

 

 

 

 

Twisted or restricted discharge

Lay hose flat un-kinked. Remove clog from hose line.

 

hose?

 

 

 

 

 

Clogged pump strainer?

Clean strainer.

Pump Fails to Deliver Full

 

 

 

Use a voltmeter to check voltage while pump is energized. Voltage

Output

 

Low voltage?

must be within ±10%. Check power source (no load and load). If an

 

 

extension cord is used, make sure it has adequate current-carrying

 

 

 

 

capacity for the required length.See Table 4.

 

 

 

 

Impeller worn?

Replace impeller.

 

 

 

Water in Seal Oil

Defective water seal?

Replace water seal.

 

 

Loose Oil Fill Plug?

Tighten securely.

 

 

 

 

PAGE 20 — ST2037,47, 47B, 38P, 40T SUB. PUMPS — OPERATION AND PARTS MANUAL — REV. #3 (06/15/10)

Image 20
Contents Models Submersible Pump Component Drawings Best Deal! Order via Internet Dealers Only Order via Fax Dealers OnlyPage Foryour Safety and the Safety of Others This manualGeneral Safety Maintenance Safety EmergenciesST2037, 47, 47B, 38P, 40T SUB. Pump Dimensions ST2037, 47, 47B, 38P, 40T SUB. Pump Specifications Control Box Installation Warnings IntroductionST2037, ST2047, ST2047B ST2038P ST2040T Submersible Pump ComponentsHow It Works Float Switch TheoryDesign Features Float Switch Mounting The Float SwitchCB3 Control Box and Dual Float Switch Application Diagram Control Box CB3Attaching Lifting Rope Pump Power Connections Piggy-Back Cord OnlyHose Connections Single-Phase Power Installation Input Power Cord RequirementsConnecting Dual float Switch SW-1WOP To Control Box Control Box MountingConnecting AC Power to the Control Box Connecting AC Power to the PumpGreen PersonnelDisassembly LubricationOIL Check ImpellerST2037, 47, 47B, 38P, 40T SUB. Pump Maintenance ST2037, 47, 47B, 38P, 40T SUB. Pump -TROUBLESHOOTING ST2037, 47, 47B, 38P, 40T SUB. Pump Performance Curves ST2037, 47, 47B, 38P, 40T SUB. Pump Pumpwiring Diagram Page Explanation of Code in Remarks Column Submersible Pump 1 to 3 Units ST2037, ST2047, ST2047B Electric Submersible Pump Assy Part Name QTY Remark ST2040T Electric Submersible Pump Assy Part Name RemarkST2038P- Electric Submersible Pump Assy Impeller Special Expediting Service Payment TermsFreight Policy Minimum OrderPage HERE’S HOW to GET Help Canada