Desa SVYD18NRA/PRA SERIES installation manual Product Identification

Page 4

SAFETY INFORMATION

Continued

3.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

if you cannot reach your gas supplier, call the fire department

4.This heater shall not be installed in a bedroom or bathroom.

5.Do not use this stove as a wood burning fire- place. Use only model SVYD18PRA/NRA se- ries vent-free gas log heater for VCIS(*), PVCIS(*), and VH(*)A series cast iron stove models.

6.Do not add extra logs or ornaments such as pine cones, vermiculite, or rock wool. Using these added items can cause sooting.

7.This log heater is designed to be smokeless. If logs ever appear to smoke, turn off heater and call a qualified service person. Note: Dur- ing initial operation, slight smoking could oc- cur due to log curing and heater burning manu- facturing residues.

8.To prevent the creation of soot, follow the instructions in Cleaning and Maintenance, page 18.

9.Before using furniture polish, wax, carpet cleaners, or similar products, turn heater off. If heated, the vapors from these products may create a white powder residue within burner box or on adjacent walls or furniture.

10.This heater needs fresh, outside air ventila- tion to run properly. This heater has an Oxy- gen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the heater if not enough fresh air is available. See Air for Com- bustion and Ventilation, pages 5 through 7. If heater keeps shutting off, see Troubleshoot- ing, pages 19 through 21.

11.Do not run heater

where flammable liquids or vapors are used or stored

under dusty conditions

12.Do not use this stove to cook food or burn paper or other objects.

13.Do not use heater if any part has been exposed to or under water. Immediately call a quali- fied service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water.

14.Do not operate heater if any log is broken. Do not operate heater if a log is chipped (dime- sized or larger).

15.Turn heater off and let cool before servicing. Only a qualified service person should ser- vice and repair heater.

16.Operating heater above elevations of 4,500 feet could cause pilot outage.

17.To prevent performance problems, the use of a propane/LP tank of less than 100 lb. capac- ity (propane/LP units only).

18.Provide adequate clearances around air openings.

PRODUCT

IDENTIFICATION

Stove

Body

One Piece

Log Set Inside

Stove Cavity

Stove Door (Shown in the open position)

Piezo

Optional

Control

Ignitor

Remote

Knob

Gas Log Heater

Selector

Flame

Switch

Adjustment

Base Assembly

 

Knob

 

 

Figure 1 - Typical Stove Cabinet Model with Gas Log Heater (Shown is Oxford™ Model with Model SVYD18PRA/NRA Heater)

4

www.desatech.com

113084-01A

Image 4
Contents Oxford Victor HearthTable of Contents Safety Information Product Identification Local Codes Product FeaturesAIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater Location Unusually Tight ConstructionConfined and Unconfined Space Determining if You Have a Confined or Unconfined SpaceVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installation Check GAS TypeClearances to Combustibles Minimum Wall and Ceiling Clearances see ,Stove Cavity Assembly Lift off corrugated box enclosing stove body cratingBolt Stop Installing GAS LOG Into Stove Connecting to GAS SupplyInstallation Items Needed Side ViewPressure Testing Gas Supply Piping System Checking GAS ConnectionsFor Your Safety Read Before Lighting Pressure Testing Heater Gas ConnectionsOperating Heater Lighting InstructionsTo Turn OFF GAS To Appliance Ignitor Button Flame Adjustment KnobShutting Off Heater Manual Lighting Procedure Manual ModeOptional HAND-HELD Remote Operation ON/OFF Series Model GhrcbInspecting Burners Pilot Flame PatternBurner Primary AIR Holes Main BurnerCleaning Maintenance Burner Injector Holder and Pilot AIR Inlet HoleTroubleshooting Observed Problem Possible Cause RemedyReplace burner orifice Observed Problem Possible Cause Remedy Gas leak. See WarningIllustrated Parts Breakdown Parts List Indicates Color Suffix Designation KEY Part Description QTY Specifications Wiring DiagramReplacement Parts Service HintsAccessories Keep this Warranty Warranty InformationLimited Warranty