Enviro Complete Operating Instructions for Mini Pellet Stove: Your Official Manual

Page 7

Operating Instructions

CONTROL BOARD FUNCTIONS:

1.AUGER LIGHT: This green light will flash in conjunction with the auger pulse.

2.MODE LIGHT: Responsible for signaling the state of the control board. When the light is flashing the stove is in an automatic start mode or the thermostat has control of the unit. When the light is solid, the Heat Level Setting can be altered.

3.THERMOSTAT SWITCH: Used to set the unit’s controls to one of three mode settings; manual, high/low, or auto/off.

4.FEED RATE TRIM BUTTON: Used to change the feed rate trims in 1⁄4 second increments for all

 

 

 

 

 

 

 

 

 

 

 

 

 

feed settings. When this button is pressed, all the light will light up

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

on the Heat Output Indicator except for the one that shows the

 

 

 

 

 

 

 

 

 

 

 

 

 

current setting; the default setting is the number 4 light. To adjust

 

 

 

 

 

 

 

AUGER

 

 

 

1

the setting hold the Feed Rate Trim button down and press the Heat

 

 

 

 

 

 

 

 

 

 

9

 

 

 

 

 

 

MODE

 

 

 

 

2

Level up or down buttons to adjust the setting.

 

 

 

 

 

 

AUTO/OFF

5. COMBUSTION BLOWER TRIM BUTTON: Used to change the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

Combustion Blower trims in 5 volt increments for all feed settings

 

 

 

 

 

 

 

HIGH/LOW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MANUAL

 

until it reaches line voltage. When this button is pressed, all the light

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

will light up on the Heat Output Indicator except for the one that

8 HEAT LEVEL

FEED RATE

shows the current setting; the default setting is the number 2 light.

 

TRIM

 

To adjust the setting hold the Combustion Blower Trim button down

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

and press the Heat Level up or down buttons to adjust the setting.

 

 

 

 

 

 

 

COMBUSTION

 

 

 

 

 

 

 

 

6. ON/OFF BUTTON: Used to turn the unit ON and OFF.

 

 

 

 

 

 

 

BLOWER TRIM

 

7

 

 

 

 

 

 

 

 

 

 

 

6

7. ROOM AIR FAN ON/OFF BUTTON: Used to turn convection fan

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ROOM AIR

ON/OFF

 

on or off.

 

 

 

FAN ON/OFF

 

 

 

 

 

 

8. HEAT LEVEL ADJUSTMENT BUTTONS: When pressed, will

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

change the heat level setting of the unit up or down.

 

 

 

 

 

 

 

C-11625

 

9. HEAT OUTPUT INDICATOR: Shows the present heat output

 

 

 

 

 

 

 

 

 

 

 

 

 

setting.

Figure 2: Circuit Board Control

 

 

 

 

 

 

 

 

 

Panel Decal.

 

 

AUTOMATIC SAFETY FEATURES OF YOUR PELLET STOVE:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A.The stove will shut off when the fire goes out and the exhaust temperature drops below 120°F (49°C).

B.The stove has a high temperature safety switch. If the temperature on the hopper reaches 200°F (93°C), the auger will automatically stop and the stove will shut down when the exhaust temperature cools #4 light flashes. Dealer will have to reset the sensor. If this happens, call your local dealer to reset the 200°F (93°C) high limit switch. ALSO FIND THE REASONS WHY THE UNIT OVERHEATED.

C)The unit is equipped with a vacuum switch to monitor the venting; if it becomes blocked the vacuum switch will turn off the auger and the #2 light on the control board will flash.

OPERATING YOUR PELLET STOVE:

PRE-BURN INSTRUCTIONS: The burn pot liner holes must be clear and the liner installed properly against the ignitor tube for proper operation. Check the hopper for enough pellets to start the unit.

DO NOT OPERATE THE UNIT WITH THE DOOR OR ASH PAN OPEN.

Note: The thermostat mode can be changed during normal operation.

7

Image 7
Contents Mini a Table of Contents I. Pellet Standards IntroductionStore pellets at least 36 1 m away from the pellet stove USE of Cordwood is Prohibited by LAW Keep ASH PAN Free of RAW Fuel Dimensions of Mini SpecificationsRoom AIR FAN ON/OFF Button Used to turn convection fan Heat Level Adjustment Buttons When pressed, willOperating Instructions Combustion Blower Trim Button Used to changeThermostat Switch Manual ModeSpecial Notes Slider/Damper Adjustment KnobTools Required to Clean Unit Routine Cleaning and MaintenanceDo not Place Unburned or RAW Pellet Fuel in ASH PAN ASH PAN weeklyExhaust Passages semi-annually Blower Mechanisms season Post Season CLEAN-UPDoor Glass Replacement Exhaust Vent annuallyTo the Dealer WarrantyTo the Distributor Exclusions and Limitations Warranty Name of Owner Address Installation Data Sheet

Mini A specifications

The Enviro Mini A is a compact and efficient solution designed for a variety of environmental monitoring applications. As the demand for sustainable practices increases, the Enviro Mini A emerges as a key player in facilitating real-time data collection and analysis of environmental parameters.

One of the main features of the Enviro Mini A is its advanced sensor technology. It is equipped with high-precision sensors that can monitor various environmental factors, including air quality, temperature, humidity, and atmospheric pressure. These sensors are designed to provide accurate readings, allowing users to make informed decisions based on reliable data.

The design of the Enviro Mini A is another significant characteristic that sets it apart. Its compact size allows for easy installation in a variety of locations, from urban settings to remote areas. This versatility makes it suitable for deployments in schools, parks, industrial sites, and research facilities. The device can be mounted on poles, walls, or placed on flat surfaces, ensuring flexibility in how it can be utilized.

Connectivity is a critical aspect of the Enviro Mini A's functionality. The device is equipped with Wi-Fi and optional cellular connectivity, enabling seamless data transmission to cloud-based platforms for real-time analysis and monitoring. Users can access the data remotely via a user-friendly interface, allowing for quick responses to any environmental changes or alerts.

The Enviro Mini A also boasts a robust and weather-resistant design, making it capable of withstanding various environmental conditions. This durability ensures longevity and reliability, even in challenging outdoor settings. Furthermore, the device is energy-efficient, often powered by solar energy or a long-lasting battery, which reduces maintenance efforts and operational costs.

Incorporating advanced data analytics capabilities, the Enviro Mini A allows users to track trends over time, identify patterns, and generate reports that can assist in regulatory compliance and environmental assessments. Its integration with machine learning algorithms aids in predictive analytics, offering insights that can drive proactive environmental management strategies.

In summary, the Enviro Mini A is a state-of-the-art environmental monitoring device that combines advanced sensor technology with a robust design and connectivity features. Its versatility and analytical capabilities make it an invaluable tool for anyone looking to monitor and improve environmental conditions effectively.