Enviro Enviro Maxx owner manual Special Notes, Slider/Damper Plate in Unit

Page 9

Operating Instructions

HEAT LEVEL and Fans will drop down to the LOW setting for 30 minutes. If the thermostat contacts close within the 30 minutes, the HEAT LEVEL will return to the previous MANUAL setting. If the thermostat contacts remain open, the stove automatically begins its shutdown routine. The stove will re-light when the thermostat contacts close again.

TURNING YOUR PELLET STOVE OFF:

MANUAL and HI / LOW mode: To turn the unit OFF, simply press the ON / OFF button. This will stop the feed of pellets. The blowers will continue to operate and cool the stove down. When cool enough, the stove will turn off.

AUTO / OFF mode: To turn the unit OFF, turn the Thermostat down or Timer off.

DO NOT turn unit off during start-up or unplug unit while operating; this may lead

to smoke escaping from the stove.

SLIDER/DAMPER SET-UP:

THE SLIDER / DAMPER MUST BE SET AT TIME OF INSTALLATION. A Qualified Service Technician

or Installer must set the Slider Damper.

If the fire should happen to go out and the heat output indicator has been set on the lowest setting, the Slider Damper should be pushed in slightly, decreasing the air in the firebox.

If, after long periods of burning, the fire builds up

 

and overflows the burn pot or there is a build up of

 

clinkers, this would be a sign that the pellet quality

Exhaust Channel

is poor, this requires more primary air, the slider

 

damper must be pulled out to compensate. Pulling

Exhaust Fan

the slider damper out gives the fire more air.

 

Housing

 

 

The easiest way to make sure that an efficient flame

Slider Damper

 

is achieved is to understand the characteristics of

 

the fire.

 

 

 

 

• A tall, lazy flame with dark orange tips requires

 

more air – Open slider (pull out) slightly.

 

 

• A

short,

brisk

 

flame,

like

a

Figure 6: Slider/Damper Plate in Unit.

blowtorch,

has

 

Figure 7: Efficient Flame.

too much air – Close slider (push in) slightly.

If the flame is in the middle of these two characteristics with a bright yellow/orange, active flame with no black tips then the air is set for proper operation, refer to Figure 7.

The combustion exhaust blower is a variable speed blower controlled by the heat output button. This blower will decrease the vacuum pressure inside the stove, adjusting the air to fuel ratio.

SPECIAL NOTES:

Pellet quality is a major factor in how the Pellet stove will operate. If the pellets have a high moisture content or ash content the fire will be less efficient and has a higher possibility of the fire building up and creating clinkers (hard ash build-up).

9

Image 9
Contents Enviro Maxx Table of Contents Store pellets at least 36 1 m away from the pellet stove IntroductionSafety Warnings & Recommendations Safety Warnings & Recommendations Operating Instructions Dimensions of Maxx Maxx SpecificationsCircuit Board Control Panel Decal Unit OverheatedTo Start Press the on / OFF button. The stove will turn on Manual ModeSlider/Damper Plate in Unit Special NotesRoutine Cleaning and Maintenance Tools Required to Clean UnitHeat Exchanger Tubes Weekly ASH PAN and Door Gaskets Weekly Door Glass Cleaning WeeklyASH BOX Weekly Do not Place Unburned or RAW Pellet Fuel in ASH PANCleaning Painted Surfaces Post Season CLEAN-UPDoor Glass Replacement Firebox LinerWarranty To the DealerTo the Distributor Exclusions and Limitations Warranty Name of Owner Address Installation Data Sheet