Enviro C-11023 owner manual Through Wall Installation with Exterior Blower Kit

Page 23

Installation

TYPICAL THROUGH WALL WITH EXTERIOR BLOWER KIT INSTALLATION - HORIZONTAL TERMINATION:

EF 5

 

90° Elbow

 

45°Elbow with Rodent

 

screen or stainless

 

steel termination hood

 

2ft Riser

 

Pipe Adaptor

Electrical Cable

Exterior Blower

 

and Housing

Figure 23: Through Wall Installation with Exterior Blower Kit.

NOTE:

Ensure that all vent connections are installed by placing a small bead of high temperature silicone at each chimney connection.

Also ensure that all vertical vent sections are properly supported and that all clearances to combustibles are maintained in accordance with the vent manufacturer’s specifications.

Wall Strap

To supply power to the exhaust

Figure 24: Through Wall Installation with Exterior Blower Kit; Side View.

Install an amour coated electrical cable from the exhaust blower housing, through the wall thimble plate and attach to the pre drilled hole in the left hand rear hopper pillar. Hook up to wires from the exhaust blower wiring harness.

All electrical connections must be in accordance to local code requirements

23

Image 23
Contents Evolution Table of Contents Store pellets at least 36 1 m away from the pellet stove IntroductionI. Pellet Standards USE of Cordwood is Prohibited by LAW Keep ASH PAN Free of RAW Fuel Operating Instructions Reasons WHY the Unit OverheatedInitial START-UP See above Thermostat / Switch ModeHeat Exchanger Tubes 2-3 days Routine Cleaning and MaintenanceTools Required to Clean Unit Burner POT and Liner 2-3 daysExhaust Passages biannually Door Glass Cleaning 2-3 daysASH PAN weekly Fresh AIR Intake biannuallyBrick Panel Post Season CLEAN-UPCleaning Plated Surfaces Door Glass ReplacementScrews to take out to remove stove from pallet Installation147 mm Maximum Alcove depth Inches Installing Hearth Pad Pedestal onto EF5 Vent Termination Requirements Exhaust Fresh Air Intake Horizontal Exhaust Through Wall Installation Elbow with a rodent screen may Inside Vertical Installation Outside Vertical Installation Exterior Blower Kit Through vent holeThrough Wall Installation with Exterior Blower Kit EF5 REQUIRED, please follow the instructions below If you wish to adjust the slider damper externally notSlider/Damper Plate in Unit Special NotesWhat to do if TroubleshootingStove will not operate when hot Do notLight # 2 on Heat output bar flashing 200 F 93 C high limit temperature sensor has trippedExhaust motor will not function normally Stove keeps going out Control settings Heat Level has no effect on the fireConvection blower will not function normally Ignitor- the pellets will not light5V DC Wiring DiagramReference Number Description Part Number Parts ListParts List Parts Diagram Components SteelDiagramParts To the Distributor WarrantyTo the Dealer Name of Owner Address Installation Data Sheet