Enviro 50-1021 ASH PAN weekly, Door Glass Cleaning 2-3 days, Fresh AIR Intake biannually

Page 11

Routine Cleaning and Maintenance

ASH PAN (weekly)

This part is located under the burner, in the pedestal, and has a latching mechanism to secure it. To remove the ash pan, open the cover from the right hand side, unlock the latch on the pedestal cover and pull the pan out. Dump the ashes into a metal container stored away from combustibles. Monitor the ash level every week. Remember that different pellet fuels will have different ash contents. Ash content is a good indication of fuel efficiency and quality. Refer to “Warnings and Recommendations” for disposal of ashes. Vacuum the inside of the ash pan compartment inside the pedestal including the hole at the top back of the compartment. Replace the ash pan and close pedestal door. DO NOT PLACE UNBURNED

OR RAW PELLET FUEL IN ASH PAN.

DOOR GLASS CLEANING (2-3 days)

Cleaning of the glass must only be done when stove is cold. Open the door by lifting the handle. The glass can be cleaned by wiping down the outside and inside of the glass with a dry soft cloth.

If the glass has build up that can not be removed with only the cloth, clean the glass using paper towel and a gas appliance glass cleaner, this may be purchased through most dealers. If a gas appliance glass cleaner is not available, use a damp paper towel dipped in fly ash to clean the glass. After the glass has been cleaned use the dry soft cloth to wiping down the outside and inside of the glass.

FRESH AIR INTAKE (biannually)

Inspect periodically to be sure that it is not clogged with any foreign materials.

EXHAUST PASSAGES (biannually)

Removal of the firebox backing for bi-annual cleaning

Open the door by lifting the handle, remove the burn pot and burn pot liner.

Lubricate all screws with penetrating oil.

Remove the four (4) screws that hold the side panels in place.

With the tip of a flat screwdriver, gently lift up the side panels and remove the side panels.

Pull the center panel out.

Vacuum thoroughly.

Installation of firebox backing:

Insert center panel.

Place the side panels back into the firebox and re- install the two (2) screws on each side.

Replace the glass door and secure.

Clean thoroughly.

Heat exchanger tubes

cleaner handle.

Vacuum inside ash box

Figure 8: EF5 Open

11

Image 11
Contents Evolution Table of Contents Store pellets at least 36 1 m away from the pellet stove IntroductionI. Pellet Standards USE of Cordwood is Prohibited by LAW Keep ASH PAN Free of RAW Fuel Dimensions of EF5 SpecificationsOperating Instructions Reasons WHY the Unit OverheatedOperation When the thermostat calls for heat contacts are Special Notes Thermostat Switch in on OFF poitionHeat Exchanger Tubes 2-3 days Routine Cleaning and MaintenanceTools Required to Clean Unit Burner POT and Liner 2-3 daysExhaust Passages biannually Door Glass Cleaning 2-3 daysASH PAN weekly Fresh AIR Intake biannuallyBrick Panel Post Season CLEAN-UPCleaning Plated Surfaces Door Glass ReplacementTo the Distributor WarrantyTo the Dealer Name of Owner Address Installation Data Sheet