Operating Instructions

OPERATING YOUR PELLET STOVE:

PRE-BURN INSTRUCTIONS: The burn pot liner holes must be clear and the liner installed properly against the ignitor tube for proper operation. Check the hopper for enough pellets to start the unit.

DO NOT OPERATE THE UNIT WITH THE DOOR OR ASH PAN OPEN.

Note: The thermostat mode can be changed during normal operation.

MANUAL MODE:

All control of circuit board function is adjusted at the circuit board.

To START: Press the ON / OFF button. The stove will turn on. The system light will flash. The Auger Light will flash with each pulse of the auger (the Auger Feed Rate is pre-programmed during start-up). The Heat Level Indicator will show the Heat Level that the stove will run at after start-up.







 

 

Figure 3: Thermostat Switch in

MANUAL poition.

If this is the first time the unit has been started or the unit has run out of fuel, the auger will need to be primed. Press the Manual Auger Feed button until fuel starts to drop into the Burn Pot Liner (see

“OPERATING INSTRUCTIONS; CONTROL BOARD FUNCTIONS”).

To OPERATE: When a fire has been established, the System Light will turn solid (after approximately 10

-15 minutes) and the Auger Light will continue to flash to the corresponding Heat Level setting. The Heat Level button can now be pressed at this time to change the desired Heat Level Output setting.

The convection blower (room air blower) will turn on. The speed of this blower is controlled by the setting of the heat level output indicator. The convection blower can be turned OFF by depressing the convection blower control button. For the best efficiency and to prevent cycling, the convection blower should be left on at all times.

When operating on LOW HEAT LEVEL, the feed rate can be adjusted, using the auger trim, for different quality fuels. These settings can be used if the fire keeps going out on low (poor quality fuel). Or if the

low setting is too hot for the room (see “OPERATING INSTRUCTIONS; CONTROL BOARD FUNCTIONS”).

HIGH/LOW MODE: (Requires a thermostat)

INITIAL START-UP: See manual mode above.



 

 

OPERATION: When the thermostat calls for heat (contacts are





 

 

closed) the stove settings are adjustable as per Manual Mode. When

 

 

the thermostat contacts open, the HEAT LEVEL and Fans will drop

 

 

 

 

down to the LOW setting until the thermostat contacts close again.

Figure 4: Thermostat Switch in

*The LOW heat setting can be adjusted for different fuel qualities

HIGH/LOW poition.

(see “OPERATING INSTRUCTIONS - CONTROL BOARD FUNCTIONS”). The stove will

 

 

come back to the previous HEAT LEVEL setting when the thermostat contacts close again. AUTO/OFF MODE: (Requires a thermostat)

INITIAL START-UP: See manual mode above.

8

Image 8
Contents Evolution Table of Contents Store pellets at least 36 1 m away from the pellet stove IntroductionI. Pellet Standards USE of Cordwood is Prohibited by LAW Keep ASH PAN Free of RAW Fuel Specifications Dimensions of EF5Reasons WHY the Unit Overheated Operating InstructionsOperation When the thermostat calls for heat contacts are Thermostat Switch in on OFF poition Special NotesRoutine Cleaning and Maintenance Tools Required to Clean UnitBurner POT and Liner 2-3 days Heat Exchanger Tubes 2-3 daysDoor Glass Cleaning 2-3 days ASH PAN weeklyFresh AIR Intake biannually Exhaust Passages biannuallyPost Season CLEAN-UP Cleaning Plated SurfacesDoor Glass Replacement Brick PanelTo the Distributor WarrantyTo the Dealer Installation Data Sheet Name of Owner Address