Harman Stove Company 929 DV manual Maintenance, Replacing the Gasket, Cleaning the Glass

Page 14

MAINTENANCE

A qualified service person recommended by your Har- man dealer should conduct an annual inspection and main- tenance of your Clarity, its venting, and the installation to keep it running safely and efficiently. The following proce- dures should be performed only by a qualified service per- son. The gas supply should be turned off whenever a main- tenance procedure is performed.

If the glass front, side doors, or front access door are removed for servicing, they must be replaced prior to oper- ating the Clarity.

Removing the Glass Front for Replacement

Refer to page 7 for directions on removing the glass front. Use only authorized Harman replacement glass components available from your Harman dealer.

Replacing the Gasket

The Clarity has 5/8" diameter fiberglass gasket in the front door. Should it ever need replacement, use only the proper replacement gasket that is available from your Harman dealer. To replace the gasket, follow this procedure.

1.Open the door

2.Remove the existing gasket and clean its channel with a scraper or wire brush.

3.Lay a thin bead of high temperature silicone the entire length of the channel.

4.Lay the gasket in the channel with sufficient pressure that is stays in place.

5.Trim the excess from the end of the gasket so that it butts snugly against the other end without leaving a gap. Seal the end joint with high temperature silicone.

6.Close the door and apply firm pressure to seat the gas- ket evenly throughout.

Cleaning the Glass

The glass may be cleaned with ordinary household glass cleaner and a soft cloth or paper towel.

WARNING: Never clean the glass when it is hot. Do not use abrasive cleaners on the glass.

Inspecting the Venting

An inspection of both the inner and outer pipes of the venting system should be made during the annual service appointment. They must have no blockage and be in good repair. The vent manufacturer's instructions may provide specific suggestions or details on vent inspection. Any sec- tions that are taken apart for the inspection must be reas- sembled and sealed as required.

Cleaning the Log Set and Firebox

During the annual inspection and maintenance appoint- ment, the service person should clean dust, lint, and any light accumulation from the logs and the firebox area. An extra- soft brush should be used on the logs as they are extremely fragile; a vacuum cleaner may be used on the firebox. If at any time the logs cannot be removed or installed without forcing, the cause must be found. The logs must never be forced.

Removing the Front

See directions on page 7.

Removal & Re-installation of the Log Set for Cleaning

CAUTION: The ceramic logs are durable when handled and installed properly. However, they are delicate and may be damaged easily if not handled with care. Handling dam- age to the ceramic logs is not covered by warranty.

DO NOT HANDLE LOGS WHILE THEY ARE HOT. ALLOW PLENTY OF TIME FOR THE STOVE TO COOL COMPLETELY BEFORE HANLDING.

Remove the Branch

Detach the branch from the two locator pins and re- move it. Brush it gently and carefully place it to one side.

Remove the Center Log

Lift the center log and remove it. Brush it gently and carefully place it to one side with the branch.

Remove the Ember Strips

Carefully remove the ember strips, clean them, and place them with the other logs.

Remove the Side Brick Panels

Carefully remove first one side panel, and then the other. Clean and place to side.

Remove the Back Log and Back Brick Panel

Finally, carefully remove these two components as a single piece. Brush them gently and place them to the side.

Finish the procedure by vacuuming the interior of the fire- box, then re-install the logs and secure the glass front fol- lowing the procedures on page 8.

14

Image 14
Contents Harman Clarity 929 DV Direct Vent Gas Stove Contents Installation of the Clarity Direct Vent Gas Heater IntroductionClearances InstallationImportant Notice Horizontaland Vertical Venting Requirements VentingUse Only Approved Venting Version kit #934 Connecting To An Existing ChimneyAddition, the following must be observed Assembly Removing the Glass FrontInstall the Ember Strips Installthe BranchInstallthe Side Brick Panels Install the Center LogMaking The Connection Connecting the Heater to a GAS SupplyBurn Only the Fuel for which the Heater is Equipped Gas Pressure RequirementsConnecting the Optional Thermostat Connecting the Heater to CordsetConnecting the Cordset Monitoring the Gas Flame AIR Shutter AdjustmentAIR Shutter Adjustment Operation HOW to Light the FireHOW to Turn OFF the Fire SAFETY/LIGHTING Label Cleaning the Log Set and Firebox MaintenanceCleaning the Glass Replacing the GasketWiring Diagram Parts List ID# Part NoClarityPARTSParts Clarity Burner Module Exploded View Specifications Minimum Clearances from Combustible ConstructionConversion Kit Components Unplug the Electrical ConnectorsAppendix a Unplug the Cordset Remove the Glass FrontFront Harman Center Rear Appendix BDe-rating for High Altitude Altitude Injector Input Rate4DT -CSS Direct Vent GS Secure Vent Direct Vent System6-5/8 and 5 X Harman Gold Warranty Harman Gold Warranty

929 DV specifications

The Harman Stove Company 929 DV is a modern marvel in the world of heating appliances, bringing unmatched efficiency and performance to homes. Known for its commitment to quality, engineering, and innovation, Harman has established itself as a leader in the manufacture of wood, pellet, and gas stoves. The 929 DV model is specifically designed to enhance the heating experience while ensuring a beautiful aesthetic appeal.

One of the standout features of the Harman 929 DV is its direct vent technology. This innovative system allows for venting through an outside wall, using two pipes – one for exhaust and one for fresh air intake – which significantly improves efficiency. This setup not only ensures that your indoor air quality remains optimal but also provides flexibility in installation options, making it suitable for various home designs.

The 929 DV is equipped with a powerful burner that delivers an impressive heating capacity, capable of warming spaces sized up to 1,900 square feet. Its adjustable heat output makes it suitable for different needs, ensuring that the space remains cozy even during the coldest winter months. The unit features a user-friendly digital control panel, allowing homeowners to easily adjust the temperature settings, air intake, and blower speed for personalized comfort.

In terms of build quality, the 929 DV boasts robust construction, employing high-quality materials that ensure longevity and durability. The stainless steel and cast iron components add a touch of elegance while enhancing overall performance. Harman’s commitment to user safety is evident in the model’s advanced safety features, including an automatic shut-off mechanism and a sealed combustion chamber that minimizes the risk of hazardous emissions.

Aesthetically, the Harman 929 DV is designed to complement various interior styles, featuring a sleek, contemporary look with large glass doors that provide a beautiful view of the flames. This is accentuated by a variety of finishes available, ensuring a perfect match for any decor.

With its combination of efficiency, safety, and modern design, the Harman Stove Company 929 DV stands out as a top choice for homeowners seeking a high-quality heating solution. Whether you are looking to heat a space or simply add a focal point to your room, the 929 DV offers something for everyone, making it a worthy investment for the modern household.