Avalon Stoves Avanti PS manual 0Operation, Restrictor Adjustment, Adjusting the Fan Speed

Page 22

2 0Operation

Restrictor Adjustment

The restrictor “fine tunes” your appliance, adjusting the amount of air flowing to the flame.

NOTE: the optimal restrictor position will vary over time as soot builds up inside the exhaust system.

Not Enough Air:

If clinkers develop or the flame appears lazy and slow to blow the ash out of the firepot, pull the restrictor outward until the flame becomes active and the firepot holes remain clean. NOTE: If the restrictor is fully out yet the firepot does not remain clean, the stove needs to be cleaned and checked for air leaks (see “Maintenance” section of this manual).

Too Much Air:

If the flames are too active (small, flickering flames) or if burning pellets are expelled from the firepot, move the restrictor rod inwards until the flame slows down and no burning pellets are expelled. Another symptom of too much air is the heater “blowing the fire out” – a condition in which the pellets burn faster than they are fed (this is most common on low)

Adjusting the Fan Speed

AUTO

H UP OFF

EMANUAL

A

T DOWN MANUAL

UP START

F

AMANUAL

N

DOWN

 

Press the

AUGER

“up” or

 

“down”

 

button to

TM

adjust the

fan speed.

 

TRAVIS INDUSTRIES

HOUSE OF FIRE

Travis Industries

Newport

2 9 0 9 0 2

Image 22
Contents Newport Page Introduction Important Information Introduction1Travis Industries Newport 0 9 0 2Safety Precautions Safety Precautions Mobile Home4Table of Contents Specifications 6Installation Clearances Straight Installation Installation7Clearances Corner Installation Venting the Pellet Stove 8InstallationMaximum Venting Distance Pellet Vent Type Installation9Installing the Pellet Vent Pellet Vent Termination See the illustration belowMobile Home Requirements 0InstallationOutside Air used for combustion Setting the Restrictor Installation1Alcove Installation Requirements Not Enough Air2Installation Installation Example Direct Through-the-wall InstallationInstallation Example Interior Vertical Installation 4Installation Installation Example Class a Chimney RetrofitInstallation Example Hearth Fireplace Masonry or Z.C. metal Location of Controls Safety Notice6Operation Starting the Heater for the First Time Loading Pellets Operation1 Two Modes of Operation Manual Mode 8OperationAuto Mode To Adjust Room Temperature or Start the StoveAdjusting the Fan Speed Restrictor Adjustment0Operation Operation2 Inspect the Burn 2MaintenanceDaily Maintenance whenever using the stove Make Sure Pellets are Not Piling UpCleaning the Firepot Maintenance2Check Firepot for Clinkers Clean the Heat Exchange Tubes 4MaintenanceBi-Weekly Maintenance or every 10 bags of pellets Cleaning the Optional Gold Surfaces Door and optional GrillLet the stove cool completely before conducting service Opening The Door6Maintenance Sweep Ash Into AshpanClean the Glass Check Ashpan, Dispose if necessary8Maintenance Yearly Maintenance or every two tonsClean the Vent make sure the stove and vent is cool Replacement Parts 0MaintenanceCheck for Air Leaks Around the Door, Glass, and Ashpan Normal Operating Sounds Exhaust BlowerSafety Label Serial NoLimited 7 Year Warranty Years 1 & 2 Coverage Parts & Labor4Optional Equipment ThermostatOptional Equipment Using the Remote ThermostatRemote Thermostat 6Optional Equipment Optional LogOptional Gold Grill Optional Gold Door38Index