Breckwell P23FSL, P23I, P23FSA owner manual Horizontally Through Wall refer to Figure

Page 8

8

INSTALLATION

B.HORIZONTALLY THROUGH WALL (refer to Figure 9)

NOTE: Follow L-Vent chimney manufacturer’s instructions.

1.Position stove, adhering to clearances shown in Figures 1 & 2.

2.Locate position of hole in wall; directly behind stove exhaust vent (refer to figure 5).

3.Always maintain 3” clearance from combustible materials.

4.Install L-Vent wall thimble per L-Vent manufacturer’s instructions.

5.Attach enough piping to penetrate and extend at least 6” beyond exterior walls. A minimum 8-foot vertical pipe run is suggested where possible to reduce the possibility of smoke spillage in the event of a loss of negative pressure.

6.Attach cap and seal outside wall thimbles with non-hardening waterproof mastic.

7.Termination should not be located so that hot exhaust gases can ignite trees, shrubs, or grasses or be a hazard to children. Exhaust gases can reach temperatures of 500ºF and

cause serious burns if touched.

FIGURE 9

Locate terminations: a) not less than 3 feet above any forced air inlet located within 10 feet; b) not less than 4 feet below or horizontally from, or one foot above, any door, window or gravity air inlet into any building; c) not less than two feet from an adjacent building and not less than 7 feet above grade when located adjacent to a public walkway. Mobile home installations must use a spark arrester.

Image 8
Contents Tradition Series P23 Introduction Important InformationSafety Precautions Table of Contents Installation SpecificationsPreparation ClearancesWhen Outside AIR is not Used Combustion AIR SupplyVenting Sources of Outside Combustion AirFreestanding Installations Assembling Pedestal or LEG SET Equivalent Vent Length EVLHorizontally Through Wall refer to Figure Vertically with NEW Chimney System Refer to Figure Vertically Into Existing Chimney SystemInstallation Through Side of Masonry Chimney Vertically Into Existing Masonry FireplaceInsert Installations Assembling the Flashing SETWhen Vent Pipe Extends to Chimney TOP Refer to Figures 16 When Vent Pipe Extends Through Chimney Blanking PlateChase dimensions shown are minimums and must be maintained AS a BUILT-IN FireplaceElectrical Installation Special Mobile Home Requirements Installation in to a Factory Built Metal FireplaceOperation Proper FuelPRE-START-UP Check Building a FireRE-STARTING a Warm Stove Opening DoorRoom AIR FAN Breckwell Maintenance Tool Shutdown ProcedureSafety Features If Stove Runs OUT of PelletsOptional Thermostat Thermostat InstallationThermostat Installation Please Read this Maintenance ASH RemovalASH Disposal Freestanding Models ASH Disposal InsertBlowers CleaningVacuum USE Chimney Cleaning Daily Weekly Bi-Annually Annually or per TonPossible Causes Troubleshooting GuideStove Shuts OFF and the # 2 Light Flashes Stove Shuts OFF and the # 3 Light Flashes Stove Feeds PELLETS, but will not Ignite Possible Causes Possible RemediesSmoke Smell Coming Back Into the Home Convection Blower Shuts OFF and Comes Back onFuel feed light is on, you have a bad control board Troubleshooting Guide High Limit Switch Keeps Tripping Heat Level Setting P23Smoke Smell or Soot BUILD-UP Digital Circuit Board Timing RatesElectrical Diagram Replacement Parts P23-PNEW
Related manuals
Manual 30 pages 36.97 Kb Manual 31 pages 7.81 Kb

P23FSL, P23FSA, P23I specifications

The Breckwell P23 series pellet stoves, comprising the P23FSA, P23I, and P23FSL models, are designed to provide efficient heating solutions while maintaining ease of use and aesthetic appeal. These stoves incorporate advanced technology features that set them apart in the modern heating market.

The Breckwell P23FSA model features a traditional freestanding design that blends seamlessly with any home decor. This model is equipped with a large viewing window, allowing users to enjoy the mesmerizing flames while benefiting from its high-efficiency heating capabilities. With a heating capacity of up to 2,000 square feet, it is an ideal choice for larger spaces. The P23FSA uses a digital control board that regulates the feed rate and blower settings, ensuring a consistent and reliable heat output. Additionally, it has a self-diagnostic system that alerts users to any operational issues, making maintenance straightforward.

The P23I, on the other hand, is designed for those seeking a built-in option. This insert offers the same heating capacity as its freestanding counterpart but is specifically made to fit into existing fireplaces, combining functionality with elegance. The P23I boasts a sleek design that enhances any room, while its adjustable blower ensures optimal heat distribution. The insert is also compatible with an optional wall thermostat, providing convenience and enhanced control over the heating schedule.

Lastly, the P23FSL model features a contemporary look with sleek lines and a compact design, ideal for smaller spaces without compromising on heating efficiency. This model includes a large hopper capable of holding up to 50 pounds of pellets, allowing for extended burn times and reduced refueling frequency. The P23FSL also incorporates a user-friendly control panel, providing adjustments at the touch of a button. Like the other models, it prioritizes efficiency, with a low emissions output that aligns with modern environmental standards.

All three models are built with high-quality materials to ensure durability and longevity. They utilize a pellet-burning process that significantly reduces environmental impact compared to traditional wood stoves, making them an eco-friendly heating option. With their combination of technology, efficiency, and aesthetic appeal, the Breckwell P23 series stands out as a top choice for homeowners looking for reliable and stylish heating solutions.