INSTALLATION

B.VERTICALLY WITH NEW CHIMNEY SYSTEM (Refer to Figure 10)

NOTE: Follow L-Vent chimney manufacturer’s instructions.

OPTION: To achieve a center vertical installation a 45º elbow and a clean-out tee can be used to offset the pipe from the exhaust outlet to the rear center of the stove.

OPTION: Install L-Vent elbow in place of clean-out tee. Locate stove. Drop plumb bob to center of tee outlet, mark point on ceiling. Install ceiling support and L-Vent pipe per L-Vent manufacturer’s instructions.

1.Always maintain 3” clearance from combustible materials. When passing through additional floors or ceilings, always install firestop spacer.

2.After lining up for hole in roof, cut either around or square hole in roof, always 3” larger all the way around pipe. Install upper edge and sides of flashing under roofing materials, nail to the roof along upper edge. Do not nail lower edge. Seal nail heads with non-hardening waterproof mastic.

3.Apply non-hardening, waterproof mastic where the storm collar will meet the vent and flashing. Slide storm collar down until it sits on the flashing. Seal and install cap. Mobile home installations must use a spark arrester.

C. VERTICALLY INTO EXISTING CHIMNEY SYSTEM

FIGURE 10

 

 

Adapters are available to adapt from 3” L-Vent to 6” or 8” Class-A chimney. (Figure 11a)

As an alternative, 3” or 4” L-Vent can be run inside existing chimney to termination. (Figure 11b)

This is the preferred method.

Follow guidelines for equivalent vent length.

FIGURE 11a

FIGURE 11b

9

Image 9
Contents Tradition Series P23 Important Information IntroductionSafety Precautions Table of Contents Specifications InstallationPreparation Clearances Combustion AIR Supply When Outside AIR is not Used Venting Sources of Outside Combustion AirEquivalent Vent Length EVL Freestanding Installations Assembling Pedestal or LEG SETHorizontally Through Wall refer to Figure Vertically Into Existing Chimney System Vertically with NEW Chimney System Refer to FigureVertically Into Existing Masonry Fireplace Installation Through Side of Masonry ChimneyAssembling the Flashing SET Insert InstallationsWhen Vent Pipe Extends Through Chimney Blanking Plate When Vent Pipe Extends to Chimney TOP Refer to Figures 16AS a BUILT-IN Fireplace Chase dimensions shown are minimums and must be maintainedInstallation in to a Factory Built Metal Fireplace Electrical Installation Special Mobile Home RequirementsProper Fuel OperationPRE-START-UP Check Building a FireOpening Door Room AIR FANRE-STARTING a Warm Stove Shutdown Procedure Breckwell Maintenance ToolSafety Features If Stove Runs OUT of PelletsThermostat Installation Thermostat InstallationOptional Thermostat Please Read this ASH Removal MaintenanceASH Disposal Freestanding Models ASH Disposal InsertCleaning Vacuum USEBlowers Daily Weekly Bi-Annually Annually or per Ton Chimney CleaningTroubleshooting Guide Stove Shuts OFF and the # 2 Light FlashesPossible Causes Stove Shuts OFF and the # 3 Light Flashes Possible Causes Possible Remedies Stove Feeds PELLETS, but will not IgniteSmoke Smell Coming Back Into the Home Convection Blower Shuts OFF and Comes Back onFuel feed light is on, you have a bad control board Troubleshooting Guide Heat Level Setting P23 High Limit Switch Keeps TrippingSmoke Smell or Soot BUILD-UP Digital Circuit Board Timing RatesElectrical Diagram P23-PNEW Replacement Parts