LP Grill Conversion

IMPORTANT: Make sure you have converted the side burner to Liquid Propane prior to completing the following steps.

1.Remove the LP gas hose assembly from the flare fitting. (this has the regulator attached to it.) (See Fig. 12)

2.Using an adjustable wrench remove the

flare fitting coming out of the bottom of the grill.Once the flare fitting is removed the main gas pipe will be showing under grill. (See Fig. 13)

4.Using pipe sealant, attach the “T” Fitting to the main gas pipe coming out of the bottom of the grill and tighten with a wrench. (See Fig. 14)

5.Using pipe sealant, attach a 3/8” flared fitting to the side and bottom of the “T” fitting. (See Fig. 15)

6.Attach the Flex Line to the fitting on the side of the “T” fitting. Connect the other end of the flex line to the side burner valve. (See Fig. 16)

Note: This line can be extended using a 3/8” flared coupling and an additional flex line if necessary.

7.Attach the LP gas hose assembly to the bottom flared fitting. (See Fig. 17)

Be sure your L.P. cylinder has an overfill protection device on it. Max inlet pressure cannot exceed 10”-11” water column.

Flex Line

Fig.17

Gas Hose

LP hose/ regulator supplied with grill.

Fig. 12

Fig. 13

Main Gas Pipe

Fig. 14

Fig. 15

“T” fitting

Attach to fitting

Fig. 16

Image 8
Contents USE and Care Manual General Safety Instructions Important Safety InformationBuilt-In Instructions Planning and DesignLocation Clearance to NON-COMBUSTIBLE ConstructionAdditional Requirements Natural Gas Installation LP Side Burner Conversion LP Side Burner Conversion LP Grill Conversion Installation Instructions Installation of Side Burner PartsLeak Testing Lighting The Side BurnerWarranty Limited Lifetime Warranty