HARDWARE INSTALLATION

HARDWARE INSTALLATION

These versatile Step-Down Transformers can be mounted in a rackmount or vertical tower orientation. This versatility is especially important to growing organizations with changing needs that value having the option to position a Step-Down Transformer on a floor or in a rackmount system. Please follow the instructions below for the respective mounting methods.

SAFETY PRECAUTIONS

CAUTION! To prevent the risk of fire or electric shock, only use the supplied hardware to attach the mounting brackets.

RACKMOUNT INSTALLATION

Step 1: Rackmount ears installation

Attach the two rackmount ears to the Step-Down Transformer using the provided screws M5X8L*8pcs.

Step 2: Rackmount rail Installation

The rails adjust to mount in 48-cm (19-inch) panel racks from 52 to 91.5cm (20.5 to 36 inches) deep. Select the proper holes in the rack for positioning the Step-Down Transformer in the rack. The 2U Step-Down Transformer takes up position 1 through position 6. The 3U Step-Down Transformer takes up position 1 through position 9.

Step 3: Adjust rackmount rails to fit your rack

Attach the rackmount rail to your rack with two M5X12L screws and two plastic washers at the front of the rack. (Located in position 1 & position 6) Do not tighten the screws. Adjust the rail size on the rail assembly of your rack. Secure the rail to the rear of the rack with two M5X12L screws and two plastic washers. Tighten all screws at the front and rear of the rail.

Place the Step-Down Transformer on a flat stable surface with the front of the unit facing toward you. Secure the Step-Down Transformer to your rack with four M5X12L screws at the front of the rack. The 2U Step-Down Transformer takes up position 2 through position 5. The 3U Step-Down Transformer takes up position 2 through position 8.

CAUTION! The Step-Down Transformer must be installed above the power module.

2

Copyright © 2011 CyberPower Systems, Inc.

Image 3
Contents User’s Manual Unpacking OverviewHardware Installation Hardware InstallationSafety Precautions Rackmount Installation Attach the base stands VERTICAL/TOWER InstallationSafety Precautions Rotate the Multifunction LCD ModuleFix the bottom cover on the terminal block Hardwiring the Input TerminalsSafety Precautions Check Wiring Separate the top and bottom coversInput configuration Hardwiring the INPUT/ Output TerminalsFix the top cover on the bottom cover STEP-DOWN Transformer FRONT/REAR Panel Description Basic OperationTechnical Specifications ConfigurationModel How Do You Get Warranty Service? Who is Providing this Warranty?What Does This Warranty Cover? What is the Period of Coverage?Where Can I Get More Information? Who Pays For Shipping?What Other Limitations Apply? Conformance Approvals FCC NoticeNeed Additional Help?

OL8K10KRT3UTFHW, OL6KRT2UTFHW, OL6KRT2UTF, OL8K10KRT3UTF specifications

CyberPower Systems offers a powerful lineup of uninterruptible power supplies (UPS) designed to protect critical equipment from power disturbances. The OL8K10KRT3UTF and OL6KRT2UTF, OL6KRT2UTFHW, and OL8K10KRT3UTFHW models are engineered to deliver reliable performance, ensuring that sensitive devices remain operational during outages.

The OL8K10KRT3UTF model is a robust UPS that provides 8,000 to 10,000 VA of power. It is designed for high-demand environments such as data centers and telecom applications. One of its notable features is the Smart App Sinewave output, which delivers pure sine wave power to connected devices, ensuring compatibility and optimal performance for sensitive electronics. This model also includes an LCD panel that provides real-time status updates on battery health, load capacity, and operational modes, allowing users to monitor performance easily.

The OL6KRT2UTF and OL6KRT2UTFHW models are similarly engineered for versatility and efficiency, offering 6,000 VA of power in a compact design. The OL6KRT2UTFHW version includes additional features for high-temperature environments, making it suitable for locations with less control over ambient conditions. Both models come equipped with advanced communication ports for seamless integration with existing systems. They support various connection types, such as USB, RS-232, and optional SNMP, enabling remote management and monitoring for critical systems.

Key technologies employed across these UPS models include automatic voltage regulation (AVR), which stabilizes voltage fluctuations, thereby protecting sensitive equipment from damage. Additionally, these models feature a high-efficiency design that reduces energy consumption and operational costs, benefiting both the environment and the organization's bottom line.

CyberPower's UPS systems utilize high-capacity, maintenance-free sealed lead-acid batteries that provide extended runtime capabilities. This ensures that connected devices stay powered on during outages or fluctuations, minimizing downtime and protecting data integrity.

In conclusion, the CyberPower Systems OL8K10KRT3UTF, OL6KRT2UTF, OL6KRT2UTFHW, and OL8K10KRT3UTFHW models represent a strong commitment to reliability and innovation in power management. With their advanced features, robust design, and efficient technologies, they serve as vital components for any mission-critical infrastructure requiring consistent power protection.