Eureka 5700-5739 warranty Routine Maintenance, Periodic Maintenance

Page 7

ROUTINE MAINTENANCE (continued)

Pre-Motor

Filter

Pre-Motor Filter

Check the pre-motor filter each time the dust cup is emptied. Clean or replace as needed.

To Clean Pre-Motor Filter

1.Remove filter centered in the bottom of the dust cup compartment.

2.Shake filter to remove excess dust. If necessary, the filter can be cleaned by vacuuming with another cleaner or washing with mild detergent.

3.Reinstall filter after completely dry.

Use GENUINE EUREKA replacement pre-motor filter, Part No. 71480.

Models equipped with Cartridge Filter (Only

cartridge style filters can be used with these models.) Check the True HEPA filter each time dust cup is emptied. Replace twice a year or as needed.

True HEPA Cartridge

Latch

Filter Door Latch

To remove True HEPA cartridge filter

1.Push down on filter door latch and pull door away from cleaner.

2.Push down on HEPA cartridge latch and remove filter.

To replace True HEPA cartridge filter

1.Place bottom tabs of filter cartridge into slots. Rotate filter toward cleaner, press firmly against cleaner to latch.

Make sure True HEPA cartridge latch is secured on both sides.

2.Replace filter door by placing tabs of door into slots on cleaner. Rotate door up and against cleaner until it locks into place.

NOTE: To have the benefit of a sealed True HEPA system, you must use one of the True HEPA cartridge filter systems.

Use GENUINE EUREKA replacement True HEPA filter, HF5.

Models equipped with Filter Pads

Check the filter pad each time the dust cup is emptied. Replace twice a year or as needed.

Filter Pad

Filter

Door

Latch

To remove Filter Pad from filter door

1.Push down on filter door latch and pull door away from cleaner.

2.Lift filter pad up and out of filter door. Dispose of old filter pad.

To replace Filter Pad into filter door

1.Place new filter pad in filter door.

2.Replace filter door by placing tabs of door into slots on cleaner. Rotate door up and against cleaner until it locks into place.

Use GENUINE EUREKA replacement HEPA filter, HF6.

PERIODIC MAINTENANCE

How To Change Light Bulb (Only for models with a

headlight)

NOTE: Turn off the power switch and disconnect the electrical cord before changing light bulb.

1.Lower handle. Remove the screw from lens cover.

2.Pull lens cover from cleaner.

3.Pull old light bulb out of socket.

4.Push new light bulb into socket.

5.Replace lens cover.

6. Secure with screw.

Use GENUINE EUREKA replacement light bulb, Part No. 57940-2.

7

Image 7
Contents Do not return this product to the store OWNER’S GuideUSA 1-800-282-2886 Mexico Canada Service InformationGeneral Information Thermal Cut OffHelpful Information Quick ReferenceAttach Hose HOW to AssembleStore Hose and Accessories Attach HandleHose or Wand HOW to USEPlace desired accessory onto end of hose or wand Nested extension wands to add reachRemoving the Dust Bag Style LS Routine MaintenanceInstalling New Dust Bag Reinstalling the Dust Bag CoverPeriodic Maintenance Routine MaintenanceBrush Roll How To Replace Brush Roll BeltBrush Roll Belt, Style U Hose Problem SolvingTo Clear Blockages in Hose LowerEureka Limited Warranty

5700-5739 specifications

The Eureka 5700-5739 series represents a remarkable lineup of advanced cleaning machines designed specifically for industrial and commercial use. These models are engineered to deliver optimal performance in a variety of environments, including warehouses, large retail spaces, and manufacturing facilities. One of the most notable features of the Eureka 5700-5739 series is its powerful suction technology. Equipped with high-efficiency motors, these machines provide superior dirt and debris removal, ensuring that surfaces remain clean and safe for operation.

Another key characteristic of the Eureka 5700-5739 series is its versatility. These machines are available in different configurations, allowing users to select models that suit their specific cleaning needs. Whether it is a compact version for tight spaces or a larger model for expansive areas, the series caters to all requirements. Additionally, each model is designed with user-friendly controls that facilitate easy operation, even for operators with minimal training.

The construction of the Eureka 5700-5739 series reflects a commitment to durability and ergonomics. Built from high-quality materials, these machines are designed to withstand the rigors of daily use. Features such as reinforced chassis and heavy-duty wheels enhance mobility, making it easier to transport the units from one location to another. Ergonomic design elements, including adjustable handles, ensure that operators can maneuver the machines with minimal physical strain, thereby promoting safety and efficiency.

Advanced filtration technology is another standout aspect of the Eureka 5700-5739 series. The machines are equipped with HEPA filters, which capture fine dust and allergens, contributing to improved air quality in the workplace. This is particularly beneficial in settings where sensitive operations take place or where employees may be exposed to dust and contaminants.

In terms of maintenance, the Eureka 5700-5739 series features easily accessible components, simplifying routine checks and part replacement. This design consideration significantly reduces downtime, allowing businesses to maintain consistent cleaning schedules without interruption.

Overall, the Eureka 5700-5739 series combines power, versatility, and user-friendly features to deliver a cleaning solution that meets the demands of modern industrial environments. Its focus on durability, advanced filtration, and ergonomic design makes it a reliable choice for those seeking effective and efficient cleaning solutions.