Dell R320 owner manual Hard-Drive Indicator Patterns, PCIe indicator Condition, Error, Off

Page 16

PCIe indicator

Condition

Corrective Action

The indicator blinks Restart the system. Update any required drivers for the PCIe card. amber if a PCIe card Re-install the card. If the problem persists, see Getting Help. experiences an

error.

Hard-Drive Indicator Patterns

Figure 5. Hard-Drive Indicators

1.hard-drive activity indicator (green)

2.hard-drive status indicator (green and amber)

NOTE: If the hard drive is in Advanced Host Controller Interface (AHCI) mode, the status indicator (on the right side) does not function and remains off.

Drive-Status Condition

Indicator Pattern

(RAID Only)

Blinks green two Identifying drive or preparing for removal times per second

Off

Drive ready for insertion or removal

NOTE: The drive status indicator remains off until all hard drives are initialized after the system is turned on. Drives are not ready for insertion or removal during this time.

Blinks green, amber,

Predicted drive failure

and off

 

Blinks amber four

Drive failed

times per second

 

Blinks green slowly

Drive rebuilding

Steady green

Drive online

16

Image 16
Contents Regulatory Model E18S Series Regulatory Type E18S001 Dell Inc. All Rights Reserved Contents Installing System Components Installing Memory ModulesInstalling The Optical Drive In Cabled Hard-Drive Systems Troubleshooting Your System 103Using System Diagnostics Jumpers And ConnectorsTechnical Specifications System MessagesPage Front-Panel Features And Indicators Indicator, Button, or Icon Description ConnectorFollowed by descriptive text Button SystemLCD Panel Features Pressed againSetup Menu Set errorHome Screen Button DescriptionDiagnostic Indicators View MenuElectrical indicator Condition Hard-drive indicator ConditionMemory indicator Corrective Action Hard-Drive Indicator Patterns PCIe indicator ConditionError Drive-Status Condition Indicator Pattern RAID OnlyBack-Panel Features And Indicators SecondsNIC Indicator Codes Power Indicator Codes Capacity of the other installed power supply Power Indicator Condition PatternOther Information You May Need Choosing The System Boot Mode Keystroke DescriptionF10 F11 F12Responding To Error Messages Entering System SetupUsing The System Setup Navigation Keys System Setup Options System Setup Main ScreenSystem Bios Screen System Information ScreenMemory Settings Screen Processor Settings ScreenOption is set to Enabled Prefetcher option is set to EnabledExecute Disable Execute Disable option is set to EnabledSata Settings Screen Boot Settings ScreenIntegrated Devices Screen System Profile Settings Screen Serial Communications ScreenSystem Security Screen System And Setup Password Features Miscellaneous SettingsAssigning a System And/Or Setup Password Using Your System Password To Secure Your System Deleting Or Changing An Existing Setup PasswordOperating With a Setup Password Enabled Entering The Uefi Boot Manager Using The Boot Manager Navigation KeysExits the Boot Manager and proceeds with system boot Displays the System Setup help fileBoot Manager Screen IDRAC Settings UtilityEmbedded System Management Entering The iDRAC Settings Utility Changing The Thermal SettingsPage Recommended Tools Installing The Front BezelFront Bezel Optional Removing The Front Bezel Opening And Closing The SystemOpening The System Inside The System Closing The SystemProcessor heat sink Cooling Shroud Removing The Cooling ShroudInstalling The Cooling Shroud Removing and Installing the Cooling ShroudSystem Memory Rdimm Mode-Specific Guidelines General Memory Module Installation Guidelines1333, 1066, Dual rank Quad rank Dimm Size in GB Number of DIMMs Dimm Rank Sample Memory ConfigurationsOrganization, Removing Memory Modules Ejecting The Memory ModuleInstalling Memory Modules Removing The Memory ModuleInstalling The Memory Module Hard DrivesRemoving a 2.5 Inch Hard-Drive Blank DrivesEight hard-drive Systems DrivesInstalling a 2.5 Inch Hard-Drive Blank Installing a 3.5 Inch Hard-Drive BlankRemoving a 3.5 Inch Hard-Drive Blank Removing a Hot-Swap Hard DriveInstalling a Hot-Swap Hard Drive Removing and Installing a Hot-Swap Hard DriveRemoving and Installing a Cabled Hard Drive Removing a Cabled Hard DriveInstalling a Cabled Hard Drive Screws Inch hard-drive adapter Inch hard drive Hard-drive carrier Screws Hard drive Screw holes Page Screws Hard drive Screw holes Hard-drive carrier Optical Drive Optional Removing The Optical Drive In Cabled Hard-Drive Systems Installing The Optical Drive In Cabled Hard-Drive Systems Cooling Fans Removing a Cooling FanInstalling a Cooling Fan Removing and Installing a Cooling FanExpansion Cards And Expansion-Card Risers Internal USB Memory Key OptionalReplacing The Internal USB Key Riser PCIe Slot Generation Height Length Link Expansion Card Installation GuidelinesWidth Removing and Installing the Expansion Card in Riser Removing An Expansion CardInstalling An Expansion Card Removing and Installing the Expansion Card in RiserRemoving and Installing the Expansion-Card Riser Removing Expansion-Card RisersInstalling Expansion-Card Risers Removing and Installing the Expansion-Card RiserIDRAC Ports Card Optional Removing The iDRAC Ports CardSD vFlash Card Installing The iDRAC Ports CardReplacing An SD vFlash Card Internal Dual SD Module Removing The Internal Dual SD ModuleInstalling The Internal Dual SD Module Removing and Installing the Internal Dual SD ModuleInstalling An Internal SD Card Internal SD CardIntegrated Storage Controller Card Removing An Internal SD CardRemoving The Integrated Storage Controller Card Processor Installing The Integrated Storage Controller CardRemoving a Processor Removing and Installing the Processor Heat Sink Installing a Processor Removing and Installing a ProcessorPower Supplies Hot Spare FeatureRemoving a Redundant Power Supply Removing and Installing a Redundant Power SupplyInstalling a Redundant Power Supply Removing a Non-Redundant Power SupplyInstalling a Non-Redundant Power Supply Removing and Installing a Non-Redundant Power SupplySystem Battery Removing The Power Supply BlankInstalling The Power Supply Blank Replacing The System BatteryReplacing the System Battery Hard-Drive BackplaneRemoving The Hard-Drive Backplane Front View of the Four Hard-Drive BackplaneRelease tabs Hard-drive backplane Guide pins Chassis hooks System board Hard-drive backplane Release tabs Chassis hooks Control Panel Assembly Installing The Hard-Drive BackplaneRemoving The Control Panel Installing The Control Panel Removing The Control-Panel Module LED-panel screws Control-panel module Installing The Control-Panel Module VGA Module Removing The VGA ModuleInstalling The VGA Module Power Distribution Board ShroudRemoving The Power Distribution Board Shroud Installing The Power Distribution Board Shroud Removing and Installing the PDB ShroudPower Distribution Board Removing The Power Distribution BoardSystem Board Installing The Power Distribution BoardRemoving The System Board Installing The System Board Removing and Installing the System BoardPage Troubleshooting The Video Subsystem Troubleshooting External ConnectionsTroubleshooting a USB Device Troubleshooting a Serial I/O Device Troubleshooting a NICTroubleshooting a Wet System Troubleshooting a Damaged SystemTroubleshooting The System Battery Troubleshooting Power SuppliesTroubleshooting Cooling Fans Troubleshooting Cooling ProblemsTroubleshooting System Memory Troubleshooting An Internal USB Key Troubleshooting An SD CardTroubleshooting An Optical Drive Troubleshooting a Tape Backup Unit Troubleshooting a Hard DriveTroubleshooting a Storage Controller Troubleshooting Expansion CardsTroubleshooting Processors When To Use The Embedded System Diagnostics Dell Online Diagnostics Dell Embedded System DiagnosticsRunning The Embedded System Diagnostics System Diagnostic Controls Least one event description is recordedSystem Board Jumper Settings Jumper Setting DescriptionSystem Board Connectors Connector DescriptionDisabling a Forgotten Password 118 Expansion slots using riser card ProcessorExpansion Bus MemoryFront Connectors BackInternal Expanded Operating Temperature Environmental TemperatureTemperature Continuous Operation VideoEnvironmental Relative HumidityMaximum Vibration Maximum ShockGaseous Contamination Air must be free of corrosive dust124 System Error Messages LCD MessagesViewing LCD Messages Removing LCD MessagesError Code AMP0302 MessageDetails ActionASR0003 Message BAT0002 MessageBAT0017 Message CPU0000 MessageCPU0010 Message CPU0023 MessageCPU0204 Message CPU0700 MessageCPU0703 Message CPU0702 MessageCPU0704 Message If the issue persists, see Getting Help Action Reinstall or reconnect the hardware HWC2003 MessageFAN0000 Message Details Fan operating speed is out of range ActionMEM0000 Message MEM0001 MessageMEM0007 Message MEM0701 MessageMEM1208 Message MEM8000 MessagePCI1302 Message PCI1304 MessagePCI1320 Message PCI1342 MessagePCI1348 Message PCI1360 MessagePST0128 Message PST0129 MessagePSU0001 Message PSU0002 MessagePSU0006 Message PSU0016 MessagePSU0031 Message PSU0032 MessagePSU0034 Message PSU0035 MessagePSU0036 Message PSU0037 MessagePSU1201 Message Power supply redundancy is lost Details System power inventory changeConfiguration and power consumption System power consumptionRFM1014 Message RFM1201 MessageRFM2001 Message RFM2002 MessageSEL0006 Message All event logging is disabled Details Appear if the user disabled event loggingPower. If problem persists call support Security may be compromisedIssues persists, contact support FailedFailures TMP0121 MessageDiagnostic Messages Alert Messages142 Getting Help Contacting Dell
Related manuals
Manual 8 pages 23.63 Kb

R320 specifications

The Dell PowerEdge R320 is a significant addition to the enterprise server lineup, capturing the needs of businesses that require efficiency, reliability, and scalability. Designed for a variety of applications, the R320 caters to both light virtualization and everyday workloads. Its compact 1U form factor makes it an optimal choice for space-constrained server environments.

One of the standout features of the R320 is its support for Intel Xeon E5-2400 processors, which deliver enhanced performance with up to eight cores per processor. This multi-core capability enables businesses to handle more tasks simultaneously, leading to improved overall productivity. The server supports up to two processors, allowing organizations to scale their compute power as needed.

Memory is another critical aspect where the R320 excels. It boasts 12 DIMM slots, allowing for a maximum memory capacity of 192 GB with 16 GB DDR3 memory modules. This high memory capacity ensures that the server can manage large datasets and perform demanding computations without bottlenecks.

The storage options in the R320 are versatile, with support for up to eight 2.5-inch hot-swappable drives, providing organizations the flexibility to configure storage according to their specific needs. The server supports both SAS and SATA drives, enabling users to choose between speed and capacity. This variety allows businesses to optimize their storage for both performance-oriented applications and large volume data storage.

Networking capabilities are robust, featuring integrated Broadcom NetXtreme II dual-port 1GbE network interface cards (NICs), which enhance connectivity and provide redundancy for mission-critical operations. For additional performance, users can upgrade the NICs to 10GbE options, ensuring that the R320 can handle future network demands.

The R320 also incorporates Dell’s innovative management features through the Integrated Dell Remote Access Controller (iDRAC). This technology allows administrators to monitor the server's health remotely and perform management tasks, reducing the need for physical access to the hardware and ensuring smooth operations.

In terms of energy efficiency, the R320 includes features such as power management settings and energy-efficient components designed to minimize power consumption without compromising performance. This aspect is increasingly important as organizations seek to reduce their carbon footprint and operational costs.

Overall, the Dell PowerEdge R320 is an impressive server that combines powerful processing capabilities, flexible storage options, and advanced management features, making it a suitable choice for a wide range of enterprise applications. Whether for small to medium-sized businesses or larger enterprises, the R320 delivers the performance, scalability, and reliability necessary for today's demanding workloads.