Dell R320 owner manual Deleting Or Changing An Existing Setup Password

Page 32

Deleting Or Changing An Existing Setup Password

Ensure that the Password jumper is set to enabled and the Password Status is Unlocked before attempting to delete or change the existing System and/or Setup password. You cannot delete or change an existing System password if the Password Status is Locked.

To delete or change the existing System and/or Setup password:

1.To enter System Setup, press <F2> immediately after a power-on or reboot.

2.In the System Setup Main Menu, select System BIOS and press <Enter>. The System BIOS screen is displayed.

3.In the System BIOS Screen, select System Security and press <Enter>. The System Security screen is displayed.

4.In the System Security screen, verify that Password Status is Unlocked.

5.Select System Password, alter or delete the existing system password and press <Enter> or <Tab>.

6.Select Setup Password, alter or delete the existing setup password and press <Enter> or <Tab>.

NOTE: If you change the System and/or Setup password a message prompts you to re-enter the new password. If you delete the System and/or Setup password, a message prompts you to confirm the deletion.

7.Press <Esc> to return to the System BIOS screen. Press <Esc> again, and a message prompts you to save the changes.

NOTE: You can disable password security while logging on to the system. To disable the password security, turn on or reboot your system, type your password and press <Ctrl><Enter>.

Using Your System Password To Secure Your System

NOTE: If you have assigned a setup password, the system accepts your setup password as an alternate system password.

1.Turn on or reboot your system.

2.Type your password and press <Enter>.

When Password Status is Locked, type the password and press <Enter> when prompted at reboot.

If an incorrect system password is entered, the system displays a message and prompts you to re-enter your password. You have three attempts to enter the correct password. After the third unsuccessful attempt, the system displays an error message that the system has halted and must be powered down.

Even after you shut down and restart the system, the error message is displayed until the correct password is entered.

NOTE: You can use the Password Status option in conjunction with the System Password and Setup Password options to protect your system from unauthorized changes.

Operating With A Setup Password Enabled

If Setup Password is Enabled, enter the correct setup password before modifying most of the System Setup options. If you do not enter the correct password in three attempts, the system displays the message

Invalid Password! Number of unsuccessful password attempts: <x> System Halted! Must power down.

Even after you shut down and restart the system, the error message is displayed until the correct password is entered. The following options are exceptions:

32

Image 32
Contents Regulatory Model E18S Series Regulatory Type E18S001 Dell Inc. All Rights Reserved Contents Installing System Components Installing Memory ModulesInstalling The Optical Drive In Cabled Hard-Drive Systems Troubleshooting Your System 103Using System Diagnostics Jumpers And ConnectorsTechnical Specifications System MessagesPage Front-Panel Features And Indicators Indicator, Button, or Icon Description ConnectorFollowed by descriptive text Button SystemLCD Panel Features Pressed againSetup Menu Set errorHome Screen Button DescriptionDiagnostic Indicators View MenuMemory indicator Corrective Action Hard-drive indicator ConditionElectrical indicator Condition Hard-Drive Indicator Patterns PCIe indicator ConditionError Drive-Status Condition Indicator Pattern RAID OnlyBack-Panel Features And Indicators SecondsNIC Indicator Codes Power Indicator Codes Other Information You May Need Power Indicator Condition PatternCapacity of the other installed power supply Choosing The System Boot Mode Keystroke DescriptionF10 F11 F12Using The System Setup Navigation Keys Entering System SetupResponding To Error Messages System Setup Options System Setup Main ScreenSystem Bios Screen System Information ScreenMemory Settings Screen Processor Settings ScreenOption is set to Enabled Prefetcher option is set to EnabledExecute Disable Execute Disable option is set to EnabledSata Settings Screen Boot Settings ScreenIntegrated Devices Screen System Profile Settings Screen Serial Communications ScreenSystem Security Screen System And Setup Password Features Miscellaneous SettingsAssigning a System And/Or Setup Password Operating With a Setup Password Enabled Deleting Or Changing An Existing Setup PasswordUsing Your System Password To Secure Your System Entering The Uefi Boot Manager Using The Boot Manager Navigation KeysExits the Boot Manager and proceeds with system boot Displays the System Setup help fileEmbedded System Management IDRAC Settings UtilityBoot Manager Screen Entering The iDRAC Settings Utility Changing The Thermal SettingsPage Front Bezel Optional Installing The Front BezelRecommended Tools Opening The System Opening And Closing The SystemRemoving The Front Bezel Inside The System Closing The SystemProcessor heat sink Cooling Shroud Removing The Cooling ShroudInstalling The Cooling Shroud Removing and Installing the Cooling ShroudSystem Memory Rdimm 1333, 1066, Dual rank Quad rank General Memory Module Installation GuidelinesMode-Specific Guidelines Organization, Sample Memory ConfigurationsDimm Size in GB Number of DIMMs Dimm Rank Removing Memory Modules Ejecting The Memory ModuleInstalling Memory Modules Removing The Memory ModuleInstalling The Memory Module Hard DrivesRemoving a 2.5 Inch Hard-Drive Blank DrivesEight hard-drive Systems DrivesInstalling a 2.5 Inch Hard-Drive Blank Installing a 3.5 Inch Hard-Drive BlankRemoving a 3.5 Inch Hard-Drive Blank Removing a Hot-Swap Hard DriveInstalling a Hot-Swap Hard Drive Removing and Installing a Hot-Swap Hard DriveRemoving and Installing a Cabled Hard Drive Removing a Cabled Hard DriveInstalling a Cabled Hard Drive Screws Inch hard-drive adapter Inch hard drive Hard-drive carrier Screws Hard drive Screw holes Page Screws Hard drive Screw holes Hard-drive carrier Optical Drive Optional Removing The Optical Drive In Cabled Hard-Drive Systems Installing The Optical Drive In Cabled Hard-Drive Systems Cooling Fans Removing a Cooling FanInstalling a Cooling Fan Removing and Installing a Cooling FanReplacing The Internal USB Key Internal USB Memory Key OptionalExpansion Cards And Expansion-Card Risers Width Expansion Card Installation GuidelinesRiser PCIe Slot Generation Height Length Link Removing and Installing the Expansion Card in Riser Removing An Expansion CardInstalling An Expansion Card Removing and Installing the Expansion Card in RiserRemoving and Installing the Expansion-Card Riser Removing Expansion-Card RisersInstalling Expansion-Card Risers Removing and Installing the Expansion-Card RiserIDRAC Ports Card Optional Removing The iDRAC Ports CardReplacing An SD vFlash Card Installing The iDRAC Ports CardSD vFlash Card Internal Dual SD Module Removing The Internal Dual SD ModuleInstalling The Internal Dual SD Module Removing and Installing the Internal Dual SD ModuleInstalling An Internal SD Card Internal SD CardIntegrated Storage Controller Card Removing An Internal SD CardRemoving The Integrated Storage Controller Card Removing a Processor Installing The Integrated Storage Controller CardProcessor Removing and Installing the Processor Heat Sink Installing a Processor Removing and Installing a ProcessorPower Supplies Hot Spare FeatureRemoving a Redundant Power Supply Removing and Installing a Redundant Power SupplyInstalling a Redundant Power Supply Removing a Non-Redundant Power SupplyInstalling a Non-Redundant Power Supply Removing and Installing a Non-Redundant Power SupplySystem Battery Removing The Power Supply BlankInstalling The Power Supply Blank Replacing The System BatteryReplacing the System Battery Hard-Drive BackplaneRemoving The Hard-Drive Backplane Front View of the Four Hard-Drive BackplaneRelease tabs Hard-drive backplane Guide pins Chassis hooks System board Hard-drive backplane Release tabs Chassis hooks Control Panel Assembly Installing The Hard-Drive BackplaneRemoving The Control Panel Installing The Control Panel Removing The Control-Panel Module LED-panel screws Control-panel module Installing The Control-Panel Module VGA Module Removing The VGA ModuleRemoving The Power Distribution Board Shroud Power Distribution Board ShroudInstalling The VGA Module Installing The Power Distribution Board Shroud Removing and Installing the PDB ShroudPower Distribution Board Removing The Power Distribution BoardRemoving The System Board Installing The Power Distribution BoardSystem Board Installing The System Board Removing and Installing the System BoardPage Troubleshooting a USB Device Troubleshooting External ConnectionsTroubleshooting The Video Subsystem Troubleshooting a Serial I/O Device Troubleshooting a NICTroubleshooting a Wet System Troubleshooting a Damaged SystemTroubleshooting The System Battery Troubleshooting Power SuppliesTroubleshooting System Memory Troubleshooting Cooling ProblemsTroubleshooting Cooling Fans Troubleshooting An Internal USB Key Troubleshooting An SD CardTroubleshooting An Optical Drive Troubleshooting a Tape Backup Unit Troubleshooting a Hard DriveTroubleshooting a Storage Controller Troubleshooting Expansion CardsTroubleshooting Processors Running The Embedded System Diagnostics Dell Online Diagnostics Dell Embedded System DiagnosticsWhen To Use The Embedded System Diagnostics System Diagnostic Controls Least one event description is recordedSystem Board Jumper Settings Jumper Setting DescriptionSystem Board Connectors Connector DescriptionDisabling a Forgotten Password 118 Expansion slots using riser card ProcessorExpansion Bus MemoryInternal Connectors BackFront Expanded Operating Temperature Environmental TemperatureTemperature Continuous Operation VideoEnvironmental Relative HumidityMaximum Vibration Maximum ShockGaseous Contamination Air must be free of corrosive dust124 System Error Messages LCD MessagesViewing LCD Messages Removing LCD MessagesError Code AMP0302 MessageDetails ActionASR0003 Message BAT0002 MessageBAT0017 Message CPU0000 MessageCPU0010 Message CPU0023 MessageCPU0204 Message CPU0700 MessageCPU0704 Message CPU0702 MessageCPU0703 Message If the issue persists, see Getting Help Action Reinstall or reconnect the hardware HWC2003 MessageFAN0000 Message Details Fan operating speed is out of range ActionMEM0000 Message MEM0001 MessageMEM0007 Message MEM0701 MessageMEM1208 Message MEM8000 MessagePCI1302 Message PCI1304 MessagePCI1320 Message PCI1342 MessagePCI1348 Message PCI1360 MessagePST0128 Message PST0129 MessagePSU0001 Message PSU0002 MessagePSU0006 Message PSU0016 MessagePSU0031 Message PSU0032 MessagePSU0034 Message PSU0035 MessagePSU0036 Message PSU0037 MessagePSU1201 Message Power supply redundancy is lost Details System power inventory changeConfiguration and power consumption System power consumptionRFM1014 Message RFM1201 MessageRFM2001 Message RFM2002 MessageSEL0006 Message All event logging is disabled Details Appear if the user disabled event loggingPower. If problem persists call support Security may be compromisedIssues persists, contact support FailedFailures TMP0121 MessageDiagnostic Messages Alert Messages142 Getting Help Contacting Dell
Related manuals
Manual 8 pages 23.63 Kb

R320 specifications

The Dell PowerEdge R320 is a significant addition to the enterprise server lineup, capturing the needs of businesses that require efficiency, reliability, and scalability. Designed for a variety of applications, the R320 caters to both light virtualization and everyday workloads. Its compact 1U form factor makes it an optimal choice for space-constrained server environments.

One of the standout features of the R320 is its support for Intel Xeon E5-2400 processors, which deliver enhanced performance with up to eight cores per processor. This multi-core capability enables businesses to handle more tasks simultaneously, leading to improved overall productivity. The server supports up to two processors, allowing organizations to scale their compute power as needed.

Memory is another critical aspect where the R320 excels. It boasts 12 DIMM slots, allowing for a maximum memory capacity of 192 GB with 16 GB DDR3 memory modules. This high memory capacity ensures that the server can manage large datasets and perform demanding computations without bottlenecks.

The storage options in the R320 are versatile, with support for up to eight 2.5-inch hot-swappable drives, providing organizations the flexibility to configure storage according to their specific needs. The server supports both SAS and SATA drives, enabling users to choose between speed and capacity. This variety allows businesses to optimize their storage for both performance-oriented applications and large volume data storage.

Networking capabilities are robust, featuring integrated Broadcom NetXtreme II dual-port 1GbE network interface cards (NICs), which enhance connectivity and provide redundancy for mission-critical operations. For additional performance, users can upgrade the NICs to 10GbE options, ensuring that the R320 can handle future network demands.

The R320 also incorporates Dell’s innovative management features through the Integrated Dell Remote Access Controller (iDRAC). This technology allows administrators to monitor the server's health remotely and perform management tasks, reducing the need for physical access to the hardware and ensuring smooth operations.

In terms of energy efficiency, the R320 includes features such as power management settings and energy-efficient components designed to minimize power consumption without compromising performance. This aspect is increasingly important as organizations seek to reduce their carbon footprint and operational costs.

Overall, the Dell PowerEdge R320 is an impressive server that combines powerful processing capabilities, flexible storage options, and advanced management features, making it a suitable choice for a wide range of enterprise applications. Whether for small to medium-sized businesses or larger enterprises, the R320 delivers the performance, scalability, and reliability necessary for today's demanding workloads.