Hoover LS manual Brush speed selector, Brush indicator, Tanks, Clean solution tank, How to fill

Page 7

2-5

The deep cleaner may also be lifted by placing a hand under the upper clean solution tank handle as shown.

2-6

E

Automatic “shut off”

When the recovery tank (lower tank) is full the automatic shutoff mechanism will shut off the deep cleaner suction (suction will be noticeably reduced).

At that time the red float disk will rise to the top of the recovery tank lid (E). The deep cleaner will no longer pick up dirty solution and the motor sound will become noticeably higher in pitch.

When this happens turn deep cleaner off and empty recovery tank before continuing use.

Check clean solution tank also; it may need to be refilled.

2-7

 

 

Brush

 

 

OFF

Speed

LO

HI

Brush speed selector

Your ‘SteamVac’ deep cleaner has three agitator brush settings.

Hl - for normal cleaning of carpet and bare floors

LO - for gentle cleaning of carpets and bare floors

OFF - for cleaning carpets and bare floors when brushing is not desired. (Such as when picking up liquid spills. See page 10.)

Slide selector button to the desired set- ting before cleaning.

2-8

F

G

Brush indicator

The brush indicator will spin (F) when the deep cleaner is turned ON and the brushes are rotating.

If the indicator does not spin and the pattern is visible (G) when the deep cleaner is turned ON, the brushes are not rotating.

There are three reasons why the brushes may not be rotating:

1.Brush speed selector set on OFF (see previous section).

2.Handle in upright position (see “CIeaning mode indicator,” Fig. 2-3).

3.Brush indicator screen dirty.

2-9

H

To clean screen (H), turn deep cleaner off and disconnect from electrical outlet.

Remove clear cover and wipe off screen with a damp cloth. Snap cover back into position.

2-10

The tanks

Clean solution tank

(upper tank)

The clean solution tank holds the clean- ing solution that is to be dispersed onto the surface to be cleaned.

How to fill

Disconnect deep cleaner from electrical outlet.

Place deep cleaner handle in the upright, locked position.

To remove tank, press down on handle and pull forward.

Carry tank to a sink.

Continued

7

Image 7 Contents
With automatic tool conversion Congratulations on your purchaseIndex Review this manual before operating deep cleanerFill in and Retain Carton contents Assembly Grounding Instructions Attach hose holder Assembled cleaner will look like this drawingAssemble handle Attach upper handleHow to reattach tool cover Powered hand toolStoring hose & tools ON/OFF pedal & Handle release pedal How to useDeep cleaner description Cleaning mode indi- catorBrush speed selector Brush indicatorClean solution tank How to fillOunces Recovery tankHow to empty Lower tankTo clean nozzle How to cleanCleaning After cleaningDisconnect deep cleaner from electri- cal outlet How to attach bare floor attachmentRead Before you begin cleaning instructions on Do not clean over floor electrical out- letsUsing the scrub tool How to attach toolsTo clean floor Before using toolAfter using scrub tool After using toolTo remove brushes MaintenanceDisconnect cleaner from electrical outlet Removable brushesStorage ServiceIf you have a problem Full One Year Warranty Domestic Use