Hoover Wind Tunnel Canister Cleaner with Powered Hand Tool owner manual If you have a problem

Page 13

4.If you have a problem

If a minor problem occurs, it usually can be solved quite easily when the cause is found by using the check list below.

Problem: Cleaner won’t run

Possible cause

Possible solution

Not “ON”at cleaner.

Turn “ON” at cleaner.

Not “ON”at hand grip.

Turn “ON at hand grip.

Not firmly plugged in.

Plug unit in firmly.

No voltage in wall plug.

Check fuse or breaker.

Blown fuse or tripped breaker.

Replace fuse/reset breaker.

Problem: Cleaner suction low

Possible cause

Possible solution

Bag full.

Replace paper bag.

Blockage in nozzle connector, hose or wands.

Remove blockage.

Secondary filter dirty.

Clean filter.

Bag not opening.

Open bag by pulling folds.

Power set too low/suction regulator open.

Increase power setting/close suction regulator.

Hose not properly connected to cleaner

Ensure hose is properly connected.

Problem: Power nozzle agitator

brush roll won’t run

Possible cause

Possible solution

Hose power cord not firmly plugged in.

Plug firmly into receptacle on cleaner base.

Broken or worn belt.

Replace belt.

Floor surface set to “BARE”.

Set floor surface to “RUG”.

Problem: Powered hand tool

brush roll won’t turn

Possible cause

Possible solution

Too much pressure being applied to tool.

Continue using tool applying light pressure.

Blockage in turbine channel.

Remove blockage

Broken or worn belt.

Replace belt.

Low cleaner suction.

Check items under “Cleaner suction low”.

Problem: Nozzle won’t pick up

Possible cause

Possible solution

Low cleaner suction.

See section “Cleaner suction low”.

Blockage in nozzle connector.

Remove blockage

Agitator brush roll not running.

See section “Agitator brush roll won’t run”

Agitator brush roll brushes worn.

Replace brushes.

Clearing blockages

Low suction or pick up may be due to a blockage in the system. Refer to the following steps to check for blockages, continuing with each step until the blockage is found:

1.Turn cleaner off and disconnect from

electrical outlet; then disconnect power nozzle plug and wands from hand grip.

4 - 1

2.Plug cleaner in, turn on, and check hose end for suction. Remove any obstructions.

3.Remove power nozzle from wands and attach wands to hose. Check for suction and remove any blockages.

4 - 2 A

4.Make sure power nozzle plug is dis- connected from hand grip. Then check for blockage in nozzle connector ( A ) .

4 - 3 B

5.Disconnect powered hand tool from hose. Remove bottom plate, belt guard and turbine as described in Figs. 3-21, 3-22 and 3-29.

Remove any blockage from turbine channel (B).

Replace belt, turbine, brush roll, belt guard and bottom plate.

13

Image 13
Contents English pp HooverP o rtant Safeguard s Carton contents Assembling cleanerConnect hose, wands and nozzle Cleaner description How to useCheck bag indicator ON-OFF switchesDeluxe power nozzle Polarized plugSuction regulator Cleaning tools11 H How to clean stairs How to store cleaner172 Filter bag MaintenanceFilters Secondary and micro 2 0 1 1 8 0 when a belt replacement is n e c e s s a ry Power Nozzle belt replacement113 Headlight re p l a c e- m e n t Agitator brush roll replacementThermal protector Powered hand tool Agitator brush roll replacement Edge groomer replacement21A Service Powered hand tool Belt replacementLubrication Inspecting the beltClearing blockages If you have a problemFull One Year Warranty Domestic Use

Wind Tunnel Canister Cleaner with Powered Hand Tool specifications

The Hoover Wind Tunnel Canister Cleaner with Powered Hand Tool embodies a blend of advanced technology and user-friendly design, making it a top choice for households seeking efficiency and thorough cleaning. Its core feature, the Wind Tunnel technology, uses powerful suction to create channels of airflow that effectively lift and remove dirt, debris, and pet hair from various surfaces. This innovative system ensures that even the most stubborn particles are extracted from carpets, upholstery, and hard floors.

One of the standout characteristics of this canister cleaner is its powered hand tool, which enhances versatility in cleaning tasks. This attachment is specifically designed to tackle upholstery and corners, allowing users to clean furniture, stairs, and other hard-to-reach areas with ease. The powered brush roll rotates at high speeds, dislodging dirt and hair while ensuring a deep clean, making it especially beneficial for pet owners.

Furthermore, the Hoover Wind Tunnel Canister Cleaner features a multi-cyclonic filtration system. This technology ensures that the suction power remains strong and consistent by separating dirt and debris from the air. The effective filtration also helps to reduce allergens, making it an ideal choice for households with allergy sufferers.

Another notable characteristic of this canister vacuum is its HEPA filter, which captures 99.97% of dust and allergens as small as 0.3 microns. This not only improves indoor air quality but also adds an extra layer of cleaning efficiency, ensuring that the air your family breathes is as clean as possible.

Portability is a key design aspect of the Hoover Wind Tunnel Canister Cleaner. Weighing significantly less than traditional upright vacuums, it includes a long power cord and a hose that extends to allow users to clean large areas without constantly changing outlets. The canister cleaner is equipped with a variety of onboard tools, including crevice tools and dusting brushes, which further enhance its cleaning capabilities.

In conclusion, the Hoover Wind Tunnel Canister Cleaner with Powered Hand Tool stands out due to its powerful suction, versatile cleaning attachments, multi-cyclonic filtration system, and lightweight design. It is a comprehensive cleaning solution that adapts to the needs of any home while delivering exceptional performance and maintaining air quality. Whether tackling pet hair, dust, or everyday dirt, this canister cleaner is designed to provide a thorough and efficient cleaning experience.